Literature DB >> 18048895

Photoplethysmography: beyond the calculation of arterial oxygen saturation and heart rate.

Kirk H Shelley1.   

Abstract

In this article, I examine the source of the photoplethysmograph (PPG), as well as methods of investigation, with an emphasize on amplitude, rhythm, and pulse analysis. The PPG waveform was first described in the 1930s. Although considered an interesting ancillary monitor, the "pulse waveform" never underwent intensive investigation. Its importance in clinical medicine was greatly increased with the introduction of the pulse oximeter into routine clinical care in the 1980s. Its waveform is now commonly displayed in the clinical setting. Active research efforts are beginning to demonstrate a utility beyond oxygen saturation and heart rate determination. Future trends are being heavily influenced by modern digital signal processing, which is allowing a re-examination of this ubiquitous waveform. Key to unlocking the potential of this waveform is an unfettered access to the raw signal, combined with standardization of its presentation, and methods of analysis. In the long run, we need to learn how to consistently quantify the characteristics of the PPG in such a way as to allow the results from research efforts be translated into clinically useful devices.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18048895     DOI: 10.1213/01.ane.0000269512.82836.c9

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  74 in total

1.  Impact of central hypovolemia on photoplethysmographic waveform parameters in healthy volunteers. Part 1: time domain analysis.

Authors:  Aymen A Alian; Nicholas J Galante; Nina S Stachenfeld; David G Silverman; Kirk H Shelley
Journal:  J Clin Monit Comput       Date:  2011-11-04       Impact factor: 2.502

2.  Pulse oximeter plethysmograph variation and its relationship to the arterial waveform in mechanically ventilated children.

Authors:  J R Chandler; E Cooke; C Petersen; W Karlen; N Froese; J Lim; J M Ansermino
Journal:  J Clin Monit Comput       Date:  2012-03-10       Impact factor: 2.502

Review 3.  Accuracy of plethysmographic indices as predictors of fluid responsiveness in mechanically ventilated adults: a systematic review and meta-analysis.

Authors:  Claudio Sandroni; Fabio Cavallaro; Cristina Marano; Chiara Falcone; Paolo De Santis; Massimo Antonelli
Journal:  Intensive Care Med       Date:  2012-06-26       Impact factor: 17.440

4.  Investigation of peripheral photoplethysmographic morphology changes induced during a hand-elevation study.

Authors:  Michelle Hickey; Justin P Phillips; Panayiotis A Kyriacou
Journal:  J Clin Monit Comput       Date:  2015-08-29       Impact factor: 2.502

5.  Spectral analysis of finger photoplethysmographic waveform variability in a model of mild to moderate haemorrhage.

Authors:  Paul M Middleton; Gregory S H Chan; Emma O'Lone; Elizabeth Steel; Rebecca Carroll; Branko G Celler; Nigel H Lovell
Journal:  J Clin Monit Comput       Date:  2008-10-11       Impact factor: 2.502

6.  Correction for pulse height variability reduces physiological noise in functional MRI when studying spontaneous brain activity.

Authors:  Petra J van Houdt; Pauly P W Ossenblok; Paul A J M Boon; Frans S S Leijten; Demetrios N Velis; Cornelis J Stam; Jan C de Munck
Journal:  Hum Brain Mapp       Date:  2010-02       Impact factor: 5.038

7.  In vitro optical detection of simulated blood pulse in a human tooth pulp model.

Authors:  A Niklas; K-A Hiller; A Jaeger; M Brandt; J Putzger; C Ermer; I Schulz; G Monkman; S Giglberger; M Hirmer; S Danilov; S Ganichev; G Schmalz
Journal:  Clin Oral Investig       Date:  2013-10-30       Impact factor: 3.573

8.  Fingertip photoplethysmographic waveform variability and systemic vascular resistance in intensive care unit patients.

Authors:  Paul M Middleton; Gregory S H Chan; Elizabeth Steel; Philip Malouf; Christopher Critoph; Gordon Flynn; Emma O'Lone; Branko G Celler; Nigel H Lovell
Journal:  Med Biol Eng Comput       Date:  2011-02-22       Impact factor: 2.602

9.  Impact of skin incision on the pleth variability index.

Authors:  Masaharu Takeyama; Akira Matsunaga; Yasuyuki Kakihana; Mina Masuda; Tamotsu Kuniyoshi; Yuichi Kanmura
Journal:  J Clin Monit Comput       Date:  2011-09-18       Impact factor: 2.502

10.  Sleep disordered breathing analysis in a general population using standard pulse oximeter signals.

Authors:  Deganit Barak-Shinar; Yariv Amos; Richard K Bogan
Journal:  Sleep Breath       Date:  2013-02-06       Impact factor: 2.816

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.