In vitro optical detection of simulated blood pulse in a human tooth pulp model.

A Niklas1, K-A Hiller, A Jaeger, M Brandt, J Putzger, C Ermer, I Schulz, G Monkman, S Giglberger, M Hirmer, S Danilov, S Ganichev, G Schmalz.   

Abstract

OBJECTIVE: Noninvasive optical methods such as photoplethysmography, established for blood pulse detection in organs, have been proposed for vitality testing of human dental pulp. However, no information is available on the mechanism of action in a closed pulp chamber and on the impairing influence of other than pulpal blood flow sources. Therefore, the aim of the present in vitro study was to develop a device for the optical detection of pulpal blood pulse and to investigate the influence of different parameters (including gingival blood flow [GBF] simulation) on the derived signals.
MATERIALS AND METHODS: Air, Millipore water, human erythrocyte suspensions (HES), non-particulate hemoglobin suspension (NPHS), and lysed hemoglobin suspension (LHES) were pulsed through a flexible (silicone) or a rigid (glass) tube placed within an extracted human molar in a tooth-gingiva model. HES was additionally pulsed through a rigid tube around the tooth, simulating GBF alone or combined with the flow through the tooth by two separate peristaltic pumps. Light from high-power light-emitting diodes (625 nm (red) and 940 nm (infrared [IR]); Golden Dragon, Osram, Germany) was introduced to the coronal/buccal part of the tooth, and the signal amplitude [∆U, in volts] of transmitted light was detected by a sensor at the opposite side of the tooth. Signal processing was carried out by means of a newly developed blood pulse detector. Finally, experiments were repeated with the application of rubber dam (blue, purple, pink, and black), aluminum foil, and black antistatic plastic foil. Nonparametric statistical analysis was applied (n = 5; α = 0.05).
RESULTS: Signals were obtained for HES and LHES, but not with air, Millipore water, or NPHS. Using a flexible tube, signals for HES were higher for IR compared to red light, whereas for the rigid tube, the signals were significantly higher for red light than for IR. In general, significantly less signal amplitude was recorded for HES with the rigid glass tube than with the flexible tube, but it was still enough to be detected. ∆U from gingiva compared to tooth was significantly lower for red light and higher for IR. Shielding the gingiva was effective for 940 nm light and negligible for 625 nm light.
CONCLUSIONS: Pulpal blood pulse can be optically detected in a rigid environment such as a pulp chamber, but GBF may interfere with the signal and the shielding effect of the rubber dam depends on the light wavelength used. CLINICAL RELEVANCE: The optically based recording of blood pulse may be a suitable method for pulp vitality testing, if improvements in the differentiation between different sources of blood pulse are possible.

Entities:  

Mesh:

Year:  2013        PMID: 24170040     DOI: 10.1007/s00784-013-1115-z

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  26 in total

1.  DIFFERENTIAL DIAGNOSIS OF PULP CONDITIONS.

Authors:  S SELTZER; I B BENDER; H NAZIMOV
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1965-03

Review 2.  Principles of pulse oximetry: theoretical and practical considerations.

Authors:  C M Alexander; L E Teller; J B Gross
Journal:  Anesth Analg       Date:  1989-03       Impact factor: 5.108

3.  The lamp effect of laser Doppler flowmetry on teeth.

Authors:  S Polat; K Er; N T Polat
Journal:  J Oral Rehabil       Date:  2005-11       Impact factor: 3.837

4.  Pulse oximetry as a diagnostic tool of pulpal vitality.

Authors:  J M Schnettler; J A Wallace
Journal:  J Endod       Date:  1991-10       Impact factor: 4.171

5.  Pulpal blood flow measurement with ultrasound Doppler imaging.

Authors:  Min-Jung Yoon; Euiseong Kim; Seoung-Jong Lee; Young-Min Bae; Sergey Kim; Sung-Ho Park
Journal:  J Endod       Date:  2010-03       Impact factor: 4.171

6.  Microvascular pressure in the dental pulp and gingiva in cats.

Authors:  K J Tønder; G Naess
Journal:  Acta Odontol Scand       Date:  1979       Impact factor: 2.331

7.  Detection of pulpal circulation in vitro by pulse oximetry.

Authors:  W C Noblett; L R Wilcox; F Scamman; W T Johnson; A Diaz-Arnold
Journal:  J Endod       Date:  1996-01       Impact factor: 4.171

8.  Effect of gingiva on laser doppler pulpal blood flow measurements.

Authors:  Kerem Engin Akpinar; Kürşat Er; Serkan Polat; Nilüfer Tülin Polat
Journal:  J Endod       Date:  2004-03       Impact factor: 4.171

9.  Efficacy of laser Doppler flowmetry in determining pulp vitality of human teeth.

Authors:  A R Ingólfsson; L Tronstad; E V Hersh; C E Riva
Journal:  Endod Dent Traumatol       Date:  1994-04

10.  The sources of laser Doppler blood-flow signals recorded from vital and root canal treated teeth.

Authors:  Serkan Polat; Kürşat Er; Kerem E Akpinar; N Tülin Polat
Journal:  Arch Oral Biol       Date:  2004-01       Impact factor: 2.633

View more
  1 in total

1.  Evaluation of the Pulp Oxygen Saturation Reading after Tooth Bleaching: A Randomized Clinical Trial.

Authors:  Dilma Helena Neves Henriques; Ana Maria Hecke Alves; Larissa Fernanda Pottmaier; Lucas da Fonseca Roberti Garcia; Eduardo Antunes Bortoluzzi; Cleonice Silveira Teixeira
Journal:  Int J Dent       Date:  2022-04-28
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.