Literature DB >> 22407178

Pulse oximeter plethysmograph variation and its relationship to the arterial waveform in mechanically ventilated children.

J R Chandler1, E Cooke, C Petersen, W Karlen, N Froese, J Lim, J M Ansermino.   

Abstract

The variations induced by mechanical ventilation in the arterial pulse pressure and pulse oximeter plethysmograph waveforms have been shown to correlate closely and be effective in adults as markers of volume responsiveness. The aims of our study were to investigate: (1) the feasibility of recording plethysmograph indices; and (2) the relationship between pulse pressure variation (ΔPP), plethysmograph variation (ΔPOP) and plethysmograph variability index (PVI) in a diverse group of mechanically ventilated children. A prospective, observational study was performed. Mechanically ventilated children less than 11 years of age, with arterial catheters, were enrolled during the course of their clinical care in the operating room or in the pediatric intensive care unit. Real time monitor waveforms and trend data were recorded. ΔPP and ΔPOP were manually calculated and the relationships between ΔPP, ΔPOP and PVI were compared using Bland-Altman analysis and Pearson correlations. Forty-nine children were recruited; four (8%) subjects were excluded due to poor quality of the plethysmograph waveforms. ΔPP and ΔPOP demonstrated a strong correlation (r = 0.8439, P < 0.0001) and close agreement (Bias = 1.44 ± 6.4%). PVI was found to correlate strongly with ΔPP (r = 0.7049, P < 0.0001) and ΔPOP (r = 0.715, P < 0.0001). This study demonstrates the feasibility of obtaining plethysmographic variability indices in children under various physiological stresses. These data show a similarly strong correlation to that described in adults, between the variations induced by mechanical ventilation in arterial pulse pressure and the pulse oximeter plethysmograph.

Entities:  

Mesh:

Year:  2012        PMID: 22407178     DOI: 10.1007/s10877-012-9347-z

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  28 in total

1.  Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure.

Authors:  F Michard; S Boussat; D Chemla; N Anguel; A Mercat; Y Lecarpentier; C Richard; M R Pinsky; J L Teboul
Journal:  Am J Respir Crit Care Med       Date:  2000-07       Impact factor: 21.405

2.  Variations in arterial blood pressure and photoplethysmography during mechanical ventilation.

Authors:  Giuseppe Natalini; Antonio Rosano; Maria E Franceschetti; Paola Facchetti; Achille Bernardini
Journal:  Anesth Analg       Date:  2006-11       Impact factor: 5.108

3.  Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre.

Authors:  M Cannesson; O Desebbe; P Rosamel; B Delannoy; J Robin; O Bastien; J-J Lehot
Journal:  Br J Anaesth       Date:  2008-06-02       Impact factor: 9.166

4.  Age-associated changes in arterial elastic properties in children.

Authors:  Hideaki Senzaki; Michio Akagi; Toshio Hishi; Akira Ishizawa; Masayoshi Yanagisawa; Satoshi Masutani; Toshiki Kobayashi; Shoich Awa
Journal:  Eur J Pediatr       Date:  2002-08-15       Impact factor: 3.183

5.  Respiratory variation in aortic blood flow velocity as a predictor of fluid responsiveness in children after repair of ventricular septal defect.

Authors:  Deok Young Choi; Hyun Jeong Kwak; Hee Yeon Park; Yong Beom Kim; Chang Hyu Choi; Ji Yeon Lee
Journal:  Pediatr Cardiol       Date:  2010-08-13       Impact factor: 1.655

6.  Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery.

Authors:  Daniel A Reuter; Thomas W Felbinger; Christian Schmidt; Erich Kilger; Oliver Goedje; Peter Lamm; Alwin E Goetz
Journal:  Intensive Care Med       Date:  2002-03-20       Impact factor: 17.440

7.  Are transoesophageal Doppler parameters a reliable guide to paediatric haemodynamic status and fluid management?

Authors:  S M Tibby; M Hatherill; A Durward; I A Murdoch
Journal:  Intensive Care Med       Date:  2001-01       Impact factor: 17.440

Review 8.  Monitoring cardiac function in intensive care.

Authors:  S M Tibby; I A Murdoch
Journal:  Arch Dis Child       Date:  2003-01       Impact factor: 3.791

9.  Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects.

Authors:  Anand Kumar; Ramon Anel; Eugene Bunnell; Kalim Habet; Sergio Zanotti; Stephanie Marshall; Alex Neumann; Amjad Ali; Mary Cheang; Clifford Kavinsky; Joseph E Parrillo
Journal:  Crit Care Med       Date:  2004-03       Impact factor: 7.598

Review 10.  Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation.

Authors:  F Michard; J L Teboul
Journal:  Crit Care       Date:  2000-09-01       Impact factor: 9.097

View more
  9 in total

1.  Using non invasive dynamic parameters of fluid responsiveness in children: there is still much to learn.

Authors:  Elena Chung; Maxime Cannesson
Journal:  J Clin Monit Comput       Date:  2012-03-20       Impact factor: 2.502

2.  On better estimating and normalizing the relationship between clinical parameters: comparing respiratory modulations in the photoplethysmogram and blood pressure signal (DPOP versus PPV).

Authors:  Paul S Addison; Rui Wang; Alberto A Uribe; Sergio D Bergese
Journal:  Comput Math Methods Med       Date:  2015-01-27       Impact factor: 2.238

3.  Respiratory modulations in the photoplethysmogram (DPOP) as a measure of respiratory effort.

Authors:  Paul S Addison
Journal:  J Clin Monit Comput       Date:  2015-09-16       Impact factor: 2.502

4.  Using machine learning models to predict oxygen saturation following ventilator support adjustment in critically ill children: A single center pilot study.

Authors:  Sam Ghazal; Michael Sauthier; David Brossier; Wassim Bouachir; Philippe A Jouvet; Rita Noumeir
Journal:  PLoS One       Date:  2019-02-20       Impact factor: 3.240

5.  Comparison of pulse pressure variation and pleth variability index in the prone position in pediatric patients under 2 years old.

Authors:  Sang-Hwan Ji; In-Kyung Song; Young-Eun Jang; Eun-Hee Kim; Ji-Hyun Lee; Jin-Tae Kim; Hee-Soo Kim
Journal:  Korean J Anesthesiol       Date:  2019-06-20

Review 6.  Fluid responsiveness in the pediatric population.

Authors:  Ji-Hyun Lee; Eun-Hee Kim; Young-Eun Jang; Hee-Soo Kim; Jin-Tae Kim
Journal:  Korean J Anesthesiol       Date:  2019-10-01

7.  Increasing signal processing sophistication in the calculation of the respiratory modulation of the photoplethysmogram (DPOP).

Authors:  Paul S Addison; Rui Wang; Alberto A Uribe; Sergio D Bergese
Journal:  J Clin Monit Comput       Date:  2014-09-11       Impact factor: 2.502

8.  Calculation of the Respiratory Modulation of the Photoplethysmogram (DPOP) Incorporating a Correction for Low Perfusion.

Authors:  Paul S Addison; Rui Wang; Scott J McGonigle; Alberto A Uribe; Sergio D Bergese
Journal:  Anesthesiol Res Pract       Date:  2014-08-07

Review 9.  Journal of Clinical Monitoring and Computing end of year summary 2019: hemodynamic monitoring and management.

Authors:  Bernd Saugel; Lester A H Critchley; Thomas Kaufmann; Moritz Flick; Karim Kouz; Simon T Vistisen; Thomas W L Scheeren
Journal:  J Clin Monit Comput       Date:  2020-03-14       Impact factor: 2.502

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.