Literature DB >> 21340639

Fingertip photoplethysmographic waveform variability and systemic vascular resistance in intensive care unit patients.

Paul M Middleton1, Gregory S H Chan, Elizabeth Steel, Philip Malouf, Christopher Critoph, Gordon Flynn, Emma O'Lone, Branko G Celler, Nigel H Lovell.   

Abstract

Low frequency variability in the fingertip photoplethysmogram (PPG) waveform has been utilized for inferring sympathetic vascular control, but its relationship with a quantitative measure of vascular tone has not been established. In this study, we examined the association between fingertip PPG waveform variability (PPGV) and systemic vascular resistance (SVR) obtained from thermodilution cardiac output (CO) and intra-arterial pressure measurements in 48 post cardiac surgery intensive care unit patients. Among the hemodynamic measurements, both CO (P < 0.05) and SVR (P < 0.0001) had statistically significant relationships with the normalized low frequency power (LF(nu)) of PPGV. The LF(nu) of baseline PPGV had moderate but significant positive correlation with SVR (r = 0.54, P < 0.0001), and a value below 52.5 nu was able to identify SVR < 900 dyn s cm⁻⁵ with sensitivity of 59% and specificity of 95%. The results have provided quantitative evidence to confirm the link between fingertip PPGV and sympathetic vascular control. Suppression of LF vasomotor waves leading to dominance of respiration-related HF fluctuations in the fingertip circulation was a specific (though not sensitive) marker of systemic vasodilatation, which could be potentially utilized for the assessment of critical care patients.

Entities:  

Mesh:

Year:  2011        PMID: 21340639     DOI: 10.1007/s11517-011-0749-8

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  31 in total

1.  Influence of thoracic sympathectomy on cardiac induced oscillations in tissue blood volume.

Authors:  M Nitzan; A Babchenko; D Shemesh; J Alberton
Journal:  Med Biol Eng Comput       Date:  2001-09       Impact factor: 2.602

2.  Frequency spectrum analysis of finger photoplethysmographic waveform variability during haemodialysis.

Authors:  Faizan Javed; Paul M Middleton; Philip Malouf; Gregory S H Chan; Andrey V Savkin; Nigel H Lovell; Elizabeth Steel; James Mackie
Journal:  Physiol Meas       Date:  2010-07-28       Impact factor: 2.833

3.  Photoplethysmography. Part 2. Influence of light source wavelength.

Authors:  L G Lindberg; P A Oberg
Journal:  Med Biol Eng Comput       Date:  1991-01       Impact factor: 2.602

4.  Spectral analysis of finger photoplethysmographic waveform variability in a model of mild to moderate haemorrhage.

Authors:  Paul M Middleton; Gregory S H Chan; Emma O'Lone; Elizabeth Steel; Rebecca Carroll; Branko G Celler; Nigel H Lovell
Journal:  J Clin Monit Comput       Date:  2008-10-11       Impact factor: 2.502

5.  Autonomic control of skin microvessels: assessment by power spectrum of photoplethysmographic waves.

Authors:  L Bernardi; A Radaelli; P L Solda; A J Coats; M Reeder; A Calciati; C S Garrard; P Sleight
Journal:  Clin Sci (Lond)       Date:  1996-05       Impact factor: 6.124

6.  Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing.

Authors:  G Parati; R Casadei; A Groppelli; M Di Rienzo; G Mancia
Journal:  Hypertension       Date:  1989-06       Impact factor: 10.190

7.  Simultaneous ipsilateral and contralateral measurements of vasomotion in conduit arteries of human upper limbs.

Authors:  C A Porret; N Stergiopulos; D Hayoz; H R Brunner; J J Meister
Journal:  Am J Physiol       Date:  1995-12

8.  Effects of sympathetic nerve blockades on low-frequency oscillations of human earlobe skin blood flow.

Authors:  H Sasano; J Hayano; T Tsuda; H Katsuya
Journal:  J Auton Nerv Syst       Date:  1999-07-07

9.  Effect of propofol on heart rate, arterial pressure and digital plethysmograph variability.

Authors:  B J Robinson; H C Buyck; D C Galletly
Journal:  Br J Anaesth       Date:  1994-08       Impact factor: 9.166

10.  Autonomic control of the heart and peripheral vessels in human septic shock.

Authors:  M Piepoli; C S Garrard; D A Kontoyannis; L Bernardi
Journal:  Intensive Care Med       Date:  1995-02       Impact factor: 17.440

View more
  7 in total

1.  Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO₂ sensor.

Authors:  M Shafique; P A Kyriacou; S K Pal
Journal:  Med Biol Eng Comput       Date:  2012-05-04       Impact factor: 2.602

2.  Photoplethysmographic characterization of vascular tone mediated changes in arterial pressure: an observational study.

Authors:  Gerardo Tusman; Cecilia M Acosta; Sven Pulletz; Stephan H Böhm; Adriana Scandurra; Jorge Martinez Arca; Matías Madorno; Fernando Suarez Sipmann
Journal:  J Clin Monit Comput       Date:  2018-12-15       Impact factor: 2.502

3.  Head hemodynamics and systemic responses during auditory stimulation.

Authors:  Vanesa Muñoz; José A Diaz-Sanchez; Manuel Muñoz-Caracuel; Carlos M Gómez
Journal:  Physiol Rep       Date:  2022-07

4.  Assessment of postoperative pain intensity by using photoplethysmography.

Authors:  Peng Ling; Yu Siyuan; Wei Wei; Gong Quan; Gao Bo
Journal:  J Anesth       Date:  2014-05-15       Impact factor: 2.078

5.  Low-frequency component of photoplethysmogram reflects the autonomic control of blood pressure.

Authors:  Anatoly S Karavaev; Anatoly S Borovik; Ekaterina I Borovkova; Eugeniya A Orlova; Margarita A Simonyan; Vladimir I Ponomarenko; Viktoriia V Skazkina; Vladimir I Gridnev; Boris P Bezruchko; Mikhail D Prokhorov; Anton R Kiselev
Journal:  Biophys J       Date:  2021-06-02       Impact factor: 3.699

6.  Vascular origins of low-frequency oscillations in the cerebrospinal fluid signal in resting-state fMRI: Interpretation using photoplethysmography.

Authors:  Ahmadreza Attarpour; James Ward; J Jean Chen
Journal:  Hum Brain Mapp       Date:  2021-02-27       Impact factor: 5.038

7.  Estimation of cardiac output and systemic vascular resistance using a multivariate regression model with features selected from the finger photoplethysmogram and routine cardiovascular measurements.

Authors:  Qim Y Lee; Stephen J Redmond; Gregory Sh Chan; Paul M Middleton; Elizabeth Steel; Philip Malouf; Cristopher Critoph; Gordon Flynn; Emma O'Lone; Nigel H Lovell
Journal:  Biomed Eng Online       Date:  2013-03-04       Impact factor: 2.819

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.