Literature DB >> 18046609

Compressed voxels for high-resolution phantom simulations in GATE.

Richard Taschereau1, Arion F Chatziioannou.   

Abstract

PURPOSE: We report here on a technique to implement high-resolution objects with voxels having variable dimensions (compressed) for the reduction of memory and central processing unit (CPU) requirements in Monte Carlo simulations. The technique, which was implemented in GATE, the GEANT4 application for positron emission tomography/single photon emission computed tomography (PET/SPECT) imaging simulations, was developed in response to our need for realistic high-resolution phantoms for dosimetry calculations. PROCEDURES: A compression algorithm similar to run-length encoding for one-dimensional data streams, was used to fuse together adjacent voxels with identical physical properties. The algorithm was verified by conducting dosimetric calculations and imaging experiments on compressed and uncompressed phantoms.
RESULTS: Depending on the initial phantom size and composition, compression ratios of up to 99.9% were achieved allowing memory and CPU reductions of up to 85% and 70%, respectively. The output of the simulations was consistent with respect to the goals for each type of simulation performed (dosimetry and imaging).
CONCLUSIONS: The implementation of compressed voxels in GATE allows for significant memory and CPU reduction and is suitable for dosimetry as well as for imaging experiments.

Entities:  

Mesh:

Year:  2008        PMID: 18046609      PMCID: PMC3005616          DOI: 10.1007/s11307-007-0110-7

Source DB:  PubMed          Journal:  Mol Imaging Biol        ISSN: 1536-1632            Impact factor:   3.488


  16 in total

1.  Resolution and noise properties of MAP reconstruction for fully 3-D PET.

Authors:  J Qi; R M Leahy
Journal:  IEEE Trans Med Imaging       Date:  2000-05       Impact factor: 10.048

2.  Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation.

Authors:  Freek J Beekman; Hugo W A M de Jong; Sander van Geloven
Journal:  IEEE Trans Med Imaging       Date:  2002-08       Impact factor: 10.048

3.  PETSIM: Monte Carlo simulation of all sensitivity and resolution parameters of cylindrical positron imaging systems.

Authors:  C J Thompson; J Moreno-Cantu; Y Picard
Journal:  Phys Med Biol       Date:  1992-03       Impact factor: 3.609

4.  GATE: a simulation toolkit for PET and SPECT.

Authors:  S Jan; G Santin; D Strul; S Staelens; K Assié; D Autret; S Avner; R Barbier; M Bardiès; P M Bloomfield; D Brasse; V Breton; P Bruyndonckx; I Buvat; A F Chatziioannou; Y Choi; Y H Chung; C Comtat; D Donnarieix; L Ferrer; S J Glick; C J Groiselle; D Guez; P F Honore; S Kerhoas-Cavata; A S Kirov; V Kohli; M Koole; M Krieguer; D J van der Laan; F Lamare; G Largeron; C Lartizien; D Lazaro; M C Maas; L Maigne; F Mayet; F Melot; C Merheb; E Pennacchio; J Perez; U Pietrzyk; F R Rannou; M Rey; D R Schaart; C R Schmidtlein; L Simon; T Y Song; J M Vieira; D Visvikis; R Van de Walle; E Wieërs; C Morel
Journal:  Phys Med Biol       Date:  2004-10-07       Impact factor: 3.609

5.  Investigation of OPET Performance Using GATE, a Geant4-Based Simulation Software.

Authors:  Fernando R Rannou; Vandana Kohli; David L Prout; Arion F Chatziioannou
Journal:  IEEE Trans Nucl Sci       Date:  2004-10       Impact factor: 1.679

6.  Fast reconstruction of 3D time-of-flight PET data by axial rebinning and transverse mashing.

Authors:  Stefaan Vandenberghe; Margaret E Daube-Witherspoon; Robert M Lewitt; Joel S Karp
Journal:  Phys Med Biol       Date:  2006-03-01       Impact factor: 3.609

7.  Monte carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom.

Authors:  Richard Taschereau; Patrick L Chow; Arion F Chatziioannou
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

8.  Computerized three-dimensional segmented human anatomy.

Authors:  I G Zubal; C R Harrell; E O Smith; Z Rattner; G Gindi; P B Hoffer
Journal:  Med Phys       Date:  1994-02       Impact factor: 4.071

9.  Monte Carlo simulations of absorbed dose in a mouse phantom from 18-fluorine compounds.

Authors:  Richard Taschereau; Arion F Chatziioannou
Journal:  Med Phys       Date:  2007-03       Impact factor: 4.071

10.  Monte Carlo simulation and scatter correction of the GE advance PET scanner with SimSET and Geant4.

Authors:  Olivier Barret; T Adrian Carpenter; John C Clark; Richard E Ansorge; Tim D Fryer
Journal:  Phys Med Biol       Date:  2005-10-04       Impact factor: 3.609

View more
  4 in total

1.  Development of GATE Monte Carlo simulation for a dual-head gamma camera.

Authors:  Mehdi Momennezhad; Ramin Sadeghi; Shahrokh Nasseri
Journal:  Radiol Phys Technol       Date:  2012-05-16

2.  Toward an organ based dose prescription method for the improved accuracy of murine dose in orthovoltage x-ray irradiators.

Authors:  Matthew D Belley; Chu Wang; Giao Nguyen; Rathnayaka Gunasingha; Nelson J Chao; Benny J Chen; Mark W Dewhirst; Terry T Yoshizumi
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

3.  The influence of small field output factors simulated uncertainties on the calculated dose in VMAT plans for brain metastases: a multicentre study.

Authors:  Stefania Clemente; Maria Daniela Falco; Elisabetta Cagni; Cinzia Talamonti; Mafalda Boccia; Eva Gino; Elena Lorenzini; Federica Rosica; Serenella Russo; Alessandro Alparone; Daniele Zefiro; Christian Fiandra
Journal:  Br J Radiol       Date:  2021-01-22       Impact factor: 3.039

4.  Development and validation of a full model of a four-headed neuroimaging single-photon emission computed tomography scanner.

Authors:  Blair A Johnston; Alice Nicol; Alison Bolster; Jamie Wright
Journal:  Nucl Med Commun       Date:  2019-01       Impact factor: 1.690

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.