Literature DB >> 16510966

Fast reconstruction of 3D time-of-flight PET data by axial rebinning and transverse mashing.

Stefaan Vandenberghe1, Margaret E Daube-Witherspoon, Robert M Lewitt, Joel S Karp.   

Abstract

Faster scintillators like LaBr(3) and LSO have sparked renewed interest in PET scanners with time-of-flight (TOF) information. The TOF information adds another dimension to the data set compared to conventional three-dimensional (3D) PET with the size of the projection data being multiplied by the number of TOF bins. Here we show by simulations and analytical reconstruction that angular sampling for two-dimensional (2D) TOF PET can be reduced significantly compared to what is required for conventional 2D PET. Fully 3D TOF PET data, however, have a wide range of oblique and transverse angles. To make use of the smaller necessary angular sampling we reduce the 3D data to a set of 2D histoprojections. This is done by rebinning the 3D data to 2D data and by mashing these 2D data into a limited number of angles. Both methods are based on the most likely point given by the TOF measurement. It is shown that the axial resolution loss associated with rebinning reduces with improved timing resolution and becomes less than 1 mm for a TOF resolution below 300 ps. The amount of angular mashing that can be applied without tangential resolution loss increases with improved TOF resolution. Even quite coarse angular mashing (18 angles out of 324 measured angles for 424 ps) does not significantly reduce image quality in terms of the contrast or noise. The advantages of the proposed methods are threefold. Data storage is reduced to a limited number of 2D histoprojections with TOF information. Compared to listmode format we have the advantage of a predetermined storage space and faster reconstruction. The method does not require the normalization of projections prior to rebinning and can be applied directly to measured listmode data.

Mesh:

Year:  2006        PMID: 16510966     DOI: 10.1088/0031-9155/51/6/017

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  19 in total

1.  Attenuation correction in emission tomography using the emission data--A review.

Authors:  Yannick Berker; Yusheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

2.  Time-of-flight PET and PET/MRI: recurrent dreams or actual realities?

Authors:  Giovanni Lucignani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-08       Impact factor: 9.236

3.  Compressed voxels for high-resolution phantom simulations in GATE.

Authors:  Richard Taschereau; Arion F Chatziioannou
Journal:  Mol Imaging Biol       Date:  2008 Jan-Feb       Impact factor: 3.488

4.  Exact and approximate Fourier rebinning of PET data from time-of-flight to non time-of-flight.

Authors:  Sanghee Cho; Sangtae Ahn; Quanzheng Li; Richard M Leahy
Journal:  Phys Med Biol       Date:  2009-01-06       Impact factor: 3.609

5.  Analytical properties of time-of-flight PET data.

Authors:  Sanghee Cho; Sangtae Ahn; Quanzheng Li; Richard M Leahy
Journal:  Phys Med Biol       Date:  2008-05-06       Impact factor: 3.609

6.  Design considerations for a limited angle, dedicated breast, TOF PET scanner.

Authors:  S Surti; J S Karp
Journal:  Phys Med Biol       Date:  2008-05-06       Impact factor: 3.609

7.  Optimization of time-of-flight reconstruction on Philips GEMINI TF.

Authors:  Stefaan Vandenberghe; Larry van Elmbt; Michel Guerchaft; Enrico Clementel; Jeroen Verhaeghe; Anne Bol; Ignace Lemahieu; Max Lonneux
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-12       Impact factor: 9.236

8.  Fast GPU-based computation of spatial multigrid multiframe LMEM for PET.

Authors:  Moulay Ali Nassiri; Jean-François Carrier; Philippe Després
Journal:  Med Biol Eng Comput       Date:  2015-04-08       Impact factor: 2.602

9.  Three-dimensional Fourier-based reprojection analytic reconstruction from histoprojections for high-resolution time-of-flight positron emission tomography scanners.

Authors:  Vladimir Y Panin; Samuel Matej
Journal:  J Med Imaging (Bellingham)       Date:  2020-06-02

Review 10.  Multimodality imaging: an update on PET/CT technology.

Authors:  Osama Mawlawi; David W Townsend
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.