Investigation of OPET Performance Using GATE, a Geant4-Based Simulation Software.

Fernando R Rannou1, Vandana Kohli, David L Prout, Arion F Chatziioannou.   

Abstract

A combined optical positron emission tomography (OPET) system is capable of both optical and PET imaging in the same setting, and it can provide information/interpretation not possible in single-mode imaging. The scintillator array here serves the dual function of coupling the optical signal from bioluminescence/fluorescence to the photodetector and also of channeling optical scintillations from the gamma rays. We report simulation results of the PET part of OPET using GATE, a Geant4 simulation package. The purpose of this investigation is the definition of the geometric parameters of the OPET tomograph. OPET is composed of six detector blocks arranged in a hexagonal ring-shaped pattern with an inner radius of 15.6 mm. Each detector consists of a two-dimensional array of 8 × 8 scintillator crystals each measuring 2 × 2 × 10 mm(3). Monte Carlo simulations were performed using the GATE software to measure absolute sensitivity, depth of interaction, and spatial resolution for two ring configurations, with and without gantry rotations, two crystal materials, and several crystal lengths. Images were reconstructed with filtered backprojection after angular interleaving and transverse one-dimensional interpolation of the sinogram. We report absolute sensitivities nearly seven times that of the prototype microPET at the center of field of view and 2.0 mm tangential and 2.3 mm radial resolutions with gantry rotations up to an 8.0 mm radial offset. These performance parameters indicate that the imaging spatial resolution and sensitivity of the OPET system will be suitable for high-resolution and high-sensitivity small-animal PET imaging.

Entities:  

Year:  2004        PMID: 16429604      PMCID: PMC1317098          DOI: 10.1109/TNS.2004.835737

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  7 in total

1.  Performance evaluation of microPET: a high-resolution lutetium oxyorthosilicate PET scanner for animal imaging.

Authors:  A F Chatziioannou; S R Cherry; Y Shao; R W Silverman; K Meadors; T H Farquhar; M Pedarsani; M E Phelps
Journal:  J Nucl Med       Date:  1999-07       Impact factor: 10.057

2.  Performance evaluation of the microPET P4: a PET system dedicated to animal imaging.

Authors:  C Tai; A Chatziioannou; S Siegel; J Young; D Newport; R N Goble; R E Nutt; S R Cherry
Journal:  Phys Med Biol       Date:  2001-07       Impact factor: 3.609

Review 3.  Monte Carlo simulations in SPET and PET.

Authors:  I Buvat; I Castiglioni
Journal:  Q J Nucl Med       Date:  2002-03

4.  GATE: a simulation toolkit for PET and SPECT.

Authors:  S Jan; G Santin; D Strul; S Staelens; K Assié; D Autret; S Avner; R Barbier; M Bardiès; P M Bloomfield; D Brasse; V Breton; P Bruyndonckx; I Buvat; A F Chatziioannou; Y Choi; Y H Chung; C Comtat; D Donnarieix; L Ferrer; S J Glick; C J Groiselle; D Guez; P F Honore; S Kerhoas-Cavata; A S Kirov; V Kohli; M Koole; M Krieguer; D J van der Laan; F Lamare; G Largeron; C Lartizien; D Lazaro; M C Maas; L Maigne; F Mayet; F Melot; C Merheb; E Pennacchio; J Perez; U Pietrzyk; F R Rannou; M Rey; D R Schaart; C R Schmidtlein; L Simon; T Y Song; J M Vieira; D Visvikis; R Van de Walle; E Wieërs; C Morel
Journal:  Phys Med Biol       Date:  2004-10-07       Impact factor: 3.609

5.  Detector Concept for OPET-A Combined PET and Optical Imaging System.

Authors:  D L Prout; R W Silverman; A Chatziioannou
Journal:  IEEE Trans Nucl Sci       Date:  2004-06       Impact factor: 1.679

6.  Assessment of response function in two PET scanners with and without interplane septa.

Authors:  C Michel; A Bol; T Spinks; D Townsend; D Bailey; S Grootoonk; T Jones
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

7.  Optical bioluminescence and positron emission tomography imaging of a novel fusion reporter gene in tumor xenografts of living mice.

Authors:  Pritha Ray; Anna M Wu; Sanjiv S Gambhir
Journal:  Cancer Res       Date:  2003-03-15       Impact factor: 12.701

  7 in total
  7 in total

1.  FPGA Electronics for OPET: A Dual-Modality Optical and Positron Emission Tomograph.

Authors:  Ali Douraghy; Fernando R Rannou; Robert W Silverman; Arion F Chatziioannou
Journal:  IEEE Trans Nucl Sci       Date:  2008-10-01       Impact factor: 1.679

2.  GATE: a simulation toolkit for PET and SPECT.

Authors:  S Jan; G Santin; D Strul; S Staelens; K Assié; D Autret; S Avner; R Barbier; M Bardiès; P M Bloomfield; D Brasse; V Breton; P Bruyndonckx; I Buvat; A F Chatziioannou; Y Choi; Y H Chung; C Comtat; D Donnarieix; L Ferrer; S J Glick; C J Groiselle; D Guez; P F Honore; S Kerhoas-Cavata; A S Kirov; V Kohli; M Koole; M Krieguer; D J van der Laan; F Lamare; G Largeron; C Lartizien; D Lazaro; M C Maas; L Maigne; F Mayet; F Melot; C Merheb; E Pennacchio; J Perez; U Pietrzyk; F R Rannou; M Rey; D R Schaart; C R Schmidtlein; L Simon; T Y Song; J M Vieira; D Visvikis; R Van de Walle; E Wieërs; C Morel
Journal:  Phys Med Biol       Date:  2004-10-07       Impact factor: 3.609

3.  Tomographic bioluminescence imaging by use of a combined optical-PET (OPET) system: a computer simulation feasibility study.

Authors:  George Alexandrakis; Fernando R Rannou; Arion F Chatziioannou
Journal:  Phys Med Biol       Date:  2005-08-24       Impact factor: 3.609

4.  Effect of optical property estimation accuracy on tomographic bioluminescence imaging: simulation of a combined optical-PET (OPET) system.

Authors:  George Alexandrakis; Fernando R Rannou; Arion F Chatziioannou
Journal:  Phys Med Biol       Date:  2006-04-03       Impact factor: 3.609

5.  Compressed voxels for high-resolution phantom simulations in GATE.

Authors:  Richard Taschereau; Arion F Chatziioannou
Journal:  Mol Imaging Biol       Date:  2008 Jan-Feb       Impact factor: 3.488

6.  Development and validation of a Monte Carlo simulation tool for multi-pinhole SPECT.

Authors:  Greta S P Mok; Yong Du; Yuchuan Wang; Eric C Frey; Benjamin M W Tsui
Journal:  Mol Imaging Biol       Date:  2009-09-25       Impact factor: 3.488

7.  Fluorescence molecular tomography: principles and potential for pharmaceutical research.

Authors:  Florian Stuker; Jorge Ripoll; Markus Rudin
Journal:  Pharmaceutics       Date:  2011-04-26       Impact factor: 6.321

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.