Literature DB >> 30394804

The effect of different image reconstruction techniques on pre-clinical quantitative imaging and dual-energy CT.

Ana Vaniqui1, Lotte E J R Schyns1, Isabel P Almeida1, Brent van der Heyden1, Mark Podesta1, Frank Verhaegen1.   

Abstract

OBJECTIVE: : To analyse the effect of different image reconstruction techniques on image quality and dual energy CT (DECT) imaging metrics.
METHODS: : A software platform for pre-clinical cone beam CT X-ray image reconstruction was built using the open-source reconstruction toolkit. Pre-processed projections were reconstructed with filtered back-projection and iterative algorithms, namely Feldkamp, Davis, and Kress (FDK), Iterative FDK, simultaneous algebraic reconstruction technique (SART), simultaneous iterative reconstruction technique and conjugate gradient. Imaging metrics were quantitatively assessed, using a quality assurance phantom, and DECT analysis was performed to determine the influence of each reconstruction technique on the relative electron density (ρe) and effective atomic number (Zeff) values.
RESULTS: : Iterative reconstruction had favourable results for the DECT analysis: a significantly smaller spread for each material in the ρe-Zeff space and lower Zeff and ρe residuals (on average 24 and 25% lower, respectively). In terms of image quality assurance, the techniques FDK, Iterative FDK and SART provided acceptable results. The three reconstruction methods showed similar geometric accuracy, uniformity and CT number results. The technique SART had a contrast-to-noise ratio up to 76% higher for solid water and twice as high for Teflon, but resolution was up to 28% lower when compared to the other two techniques.
CONCLUSIONS: : Advanced image reconstruction can be beneficial, but the benefit is small, and calculation times may be unacceptable with current technology. The use of targeted and downscaled reconstruction grids, larger, yet practicable, pixel sizes and GPU are recommended. ADVANCES IN KNOWLEDGE:: An iterative CBCT reconstruction platform was build using RTK.

Entities:  

Mesh:

Year:  2018        PMID: 30394804      PMCID: PMC6541183          DOI: 10.1259/bjr.20180447

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  24 in total

1.  AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology.

Authors:  C M Ma; C W Coffey; L A DeWerd; C Liu; R Nath; S M Seltzer; J P Seuntjens
Journal:  Med Phys       Date:  2001-06       Impact factor: 4.071

Review 2.  Iterative reconstruction methods in X-ray CT.

Authors:  Marcel Beister; Daniel Kolditz; Willi A Kalender
Journal:  Phys Med       Date:  2012-02-10       Impact factor: 2.685

3.  Potential of dual-energy subtraction for converting CT numbers to electron density based on a single linear relationship.

Authors:  Masatoshi Saito
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

4.  Evaluation of the radiation dose in micro-CT with optimization of the scan protocol.

Authors:  Inneke Willekens; Nico Buls; Tony Lahoutte; Luc Baeyens; Christian Vanhove; Vicky Caveliers; Rudi Deklerck; Axel Bossuyt; Johan de Mey
Journal:  Contrast Media Mol Imaging       Date:  2010 Jul-Aug       Impact factor: 3.161

5.  Deriving effective atomic numbers from DECT based on a parameterization of the ratio of high and low linear attenuation coefficients.

Authors:  Guillaume Landry; Joao Seco; Mathieu Gaudreault; Frank Verhaegen
Journal:  Phys Med Biol       Date:  2013-09-11       Impact factor: 3.609

6.  Empirical cupping correction: a first-order raw data precorrection for cone-beam computed tomography.

Authors:  Marc Kachelriess; Katia Sourbelle; Willi A Kalender
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

7.  A quality assurance phantom for the performance evaluation of volumetric micro-CT systems.

Authors:  Louise Y Du; Joseph Umoh; Hristo N Nikolov; Steven I Pollmann; Ting-Yim Lee; David W Holdsworth
Journal:  Phys Med Biol       Date:  2007-11-15       Impact factor: 3.609

8.  Extracting atomic numbers and electron densities from a dual source dual energy CT scanner: experiments and a simulation model.

Authors:  Guillaume Landry; Brigitte Reniers; Patrick Vincent Granton; Bart van Rooijen; Luc Beaulieu; Joachim E Wildberger; Frank Verhaegen
Journal:  Radiother Oncol       Date:  2011-09-15       Impact factor: 6.280

9.  Simulation study on potential accuracy gains from dual energy CT tissue segmentation for low-energy brachytherapy Monte Carlo dose calculations.

Authors:  Guillaume Landry; Patrick V Granton; Brigitte Reniers; Michel C Ollers; Luc Beaulieu; Joachim E Wildberger; Frank Verhaegen
Journal:  Phys Med Biol       Date:  2011-09-06       Impact factor: 3.609

10.  In vivo characterization of tumor vasculature using iodine and gold nanoparticles and dual energy micro-CT.

Authors:  Darin P Clark; Ketan Ghaghada; Everett J Moding; David G Kirsch; Cristian T Badea
Journal:  Phys Med Biol       Date:  2013-02-19       Impact factor: 3.609

View more
  3 in total

Review 1.  Status and innovations in pre-treatment CT imaging for proton therapy.

Authors:  Patrick Wohlfahrt; Christian Richter
Journal:  Br J Radiol       Date:  2019-11-11       Impact factor: 3.039

2.  Single-source dual-energy computed tomography for the detection of bone marrow lesions: impact of iterative reconstruction and algorithms.

Authors:  N Engelhard; K G Hermann; J Greese; M Fuchs; M Pumberger; M Putzier; T Diekhoff
Journal:  Skeletal Radiol       Date:  2019-12-10       Impact factor: 2.199

3.  Evaluation of a Novel Liquid Fiducial Marker, BioXmark®, for Small Animal Image-Guided Radiotherapy Applications.

Authors:  Kathryn H Brown; Mihaela Ghita; Giuseppe Schettino; Kevin M Prise; Karl T Butterworth
Journal:  Cancers (Basel)       Date:  2020-05-18       Impact factor: 6.639

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.