Literature DB >> 18029976

Direct time-of-flight for quantitative, real-time in-beam PET: a concept and feasibility study.

Paulo Crespo1, Georgy Shakirin, Fine Fiedler, Wolfgang Enghardt, Andreas Wagner.   

Abstract

We extrapolate the impact of recent detector and scintillator developments, enabling sub-nanosecond coincidence timing resolution (tau), onto in-beam positron emission tomography (in-beam PET) for monitoring charged-hadron radiation therapy. For tau < or = 200 ps full width at half maximum, the information given by the time-of-flight (TOF) difference between the two opposing gamma-rays enables shift-variant, artefact-free in-beam tomographic imaging by means of limited-angle, dual-head detectors. We present the corresponding fast, TOF-based and backprojection-free, 3D reconstruction algorithm that, coupled with a real-time data acquisition and a fast detector encoding scheme, allows the sampled beta+-activity to be visualized in the object during the course of the irradiation. Despite the very low statistics scenario typical of in-beam PET, real-treatment simulations show that in-beam TOF-PET enables high-precision images to be obtained in real-time, either with closed-ring or with fixed, dual-head in-beam TOF-PET systems. The latter greatly alleviates the installation of in-beam PET at radiotherapeutic sites.

Entities:  

Mesh:

Year:  2007        PMID: 18029976     DOI: 10.1088/0031-9155/52/23/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  19 in total

Review 1.  Innovations in Instrumentation for Positron Emission Tomography.

Authors:  Eric Berg; Simon R Cherry
Journal:  Semin Nucl Med       Date:  2018-03-12       Impact factor: 4.446

Review 2.  Focus on time-of-flight PET: the benefits of improved time resolution.

Authors:  Maurizio Conti
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-01-13       Impact factor: 9.236

Review 3.  Update on novel trends in PET/CT technology and its clinical applications.

Authors:  Stephan Walrand; Michel Hesse; François Jamar
Journal:  Br J Radiol       Date:  2016-11-25       Impact factor: 3.039

4.  Monitoring proton radiation therapy with in-room PET imaging.

Authors:  Xuping Zhu; Samuel España; Juliane Daartz; Norbert Liebsch; Jinsong Ouyang; Harald Paganetti; Thomas R Bortfeld; Georges El Fakhri
Journal:  Phys Med Biol       Date:  2011-06-15       Impact factor: 3.609

5.  Reduction method for intrinsic random coincidence events from (176)Lu in low activity PET imaging.

Authors:  Eiji Yoshida; Hideaki Tashima; Fumihiko Nishikido; Hideo Murayama; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2014-02-05

6.  Two-crossed-polarizers based optical property modulation method for ionizing radiation detection for positron emission tomography.

Authors:  Yuli Wang; Yingjie Li; Fei Yi; Junyu Li; Siwei Xie; Qiyu Peng; Jianfeng Xu
Journal:  Phys Med Biol       Date:  2019-07-05       Impact factor: 3.609

7.  Feasibility study of using fall-off gradients of early and late PET scans for proton range verification.

Authors:  Jongmin Cho; Kira Grogg; Chul Hee Min; Xuping Zhu; Harald Paganetti; Hyun Cheol Lee; Georges El Fakhri
Journal:  Med Phys       Date:  2017-03-30       Impact factor: 4.071

Review 8.  In vivo range verification in particle therapy.

Authors:  Katia Parodi; Jerimy C Polf
Journal:  Med Phys       Date:  2018-11       Impact factor: 4.071

Review 9.  Update on time-of-flight PET imaging.

Authors:  Suleman Surti
Journal:  J Nucl Med       Date:  2014-12-18       Impact factor: 10.057

Review 10.  Advances in time-of-flight PET.

Authors:  Suleman Surti; Joel S Karp
Journal:  Phys Med       Date:  2016-01-06       Impact factor: 2.685

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.