Literature DB >> 18024159

Hybrid two-dimensional navigator correction: a new technique to suppress respiratory-induced physiological noise in multi-shot echo-planar functional MRI.

Robert L Barry1, L Martyn Klassen, Joy M Williams, Ravi S Menon.   

Abstract

A troublesome source of physiological noise in functional magnetic resonance imaging (fMRI) is due to the spatio-temporal modulation of the magnetic field in the brain caused by normal subject respiration. fMRI data acquired using echo-planar imaging are very sensitive to these respiratory-induced frequency offsets, which cause significant geometric distortions in images. Because these effects increase with main magnetic field, they can nullify the gains in statistical power expected by the use of higher magnetic fields. As a study of existing navigator correction techniques for echo-planar fMRI has shown that further improvements can be made in the suppression of respiratory-induced physiological noise, a new hybrid two-dimensional (2D) navigator is proposed. Using a priori knowledge of the slow spatial variations of these induced frequency offsets, 2D field maps are constructed for each shot using spatial frequencies between +/-0.5 cm(-1) in k-space. For multi-shot fMRI experiments, we estimate that the improvement of hybrid 2D navigator correction over the best performance of one-dimensional navigator echo correction translates into a 15% increase in the volume of activation, 6% and 10% increases in the maximum and average t-statistics, respectively, for regions with high t-statistics, and 71% and 56% increases in the maximum and average t-statistics, respectively, in regions with low t-statistics due to contamination by residual physiological noise.

Mesh:

Year:  2007        PMID: 18024159      PMCID: PMC2288644          DOI: 10.1016/j.neuroimage.2007.09.060

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  33 in total

1.  An inverse problem approach to the correction of distortion in EPI images.

Authors:  P Munger; G R Crelier; T M Peters; G B Pike
Journal:  IEEE Trans Med Imaging       Date:  2000-07       Impact factor: 10.048

2.  Respiration-induced B0 fluctuations and their spatial distribution in the human brain at 7 Tesla.

Authors:  Pierre-François Van de Moortele; Josef Pfeuffer; Gary H Glover; Kamil Ugurbil; Xiaoping Hu
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

3.  Using confidence intervals for graphically based data interpretation.

Authors:  Michael E J Masson
Journal:  Can J Exp Psychol       Date:  2003-09

4.  Robust automated shimming technique using arbitrary mapping acquisition parameters (RASTAMAP).

Authors:  L Martyn Klassen; Ravi S Menon
Journal:  Magn Reson Med       Date:  2004-05       Impact factor: 4.668

5.  Image reconstruction for echo planar imaging with nonequidistant k-space sampling.

Authors:  H Bruder; H Fischer; H E Reinfelder; F Schmitt
Journal:  Magn Reson Med       Date:  1992-02       Impact factor: 4.668

6.  MR contrast due to microscopically heterogeneous magnetic susceptibility: numerical simulations and applications to cerebral physiology.

Authors:  C R Fisel; J L Ackerman; R B Buxton; L Garrido; J W Belliveau; B R Rosen; T J Brady
Journal:  Magn Reson Med       Date:  1991-02       Impact factor: 4.668

7.  Brain magnetic resonance imaging with contrast dependent on blood oxygenation.

Authors:  S Ogawa; T M Lee; A R Kay; D W Tank
Journal:  Proc Natl Acad Sci U S A       Date:  1990-12       Impact factor: 11.205

8.  Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.

Authors:  K K Kwong; J W Belliveau; D A Chesler; I E Goldberg; R M Weisskoff; B P Poncelet; D N Kennedy; B E Hoppel; M S Cohen; R Turner
Journal:  Proc Natl Acad Sci U S A       Date:  1992-06-15       Impact factor: 11.205

9.  The intrinsic signal-to-noise ratio in NMR imaging.

Authors:  W A Edelstein; G H Glover; C J Hardy; R W Redington
Journal:  Magn Reson Med       Date:  1986-08       Impact factor: 4.668

10.  Correction of spatially dependent phase shifts for partial Fourier imaging.

Authors:  J R MacFall; N J Pelc; R M Vavrek
Journal:  Magn Reson Imaging       Date:  1988 Mar-Apr       Impact factor: 2.546

View more
  6 in total

1.  The Importance of k-Space Trajectory on Off-Resonance Artifact in Segmented Echo-Planar Imaging.

Authors:  Jacob A Bender; Rizwan Ahmad; Orlando P Simonetti
Journal:  Concepts Magn Reson Part A Bridg Educ Res       Date:  2013-03-01       Impact factor: 0.481

2.  Evaluation of preprocessing steps to compensate for magnetic field distortions due to body movements in BOLD fMRI.

Authors:  Robert L Barry; Joy M Williams; L Martyn Klassen; Jason P Gallivan; Jody C Culham; Ravi S Menon
Journal:  Magn Reson Imaging       Date:  2009-08-19       Impact factor: 2.546

Review 3.  Oscillatory serotonin function in depression.

Authors:  Ronald M Salomon; Ronald L Cowan
Journal:  Synapse       Date:  2013-05-21       Impact factor: 2.562

4.  On the origins of signal variance in FMRI of the human midbrain at high field.

Authors:  Robert L Barry; Mariam Coaster; Baxter P Rogers; Allen T Newton; Jay Moore; Adam W Anderson; David H Zald; John C Gore
Journal:  PLoS One       Date:  2013-04-26       Impact factor: 3.240

5.  Multiparametric brainstem segmentation using a modified multivariate mixture of Gaussians.

Authors:  Christian Lambert; Antoine Lutti; Gunther Helms; Richard Frackowiak; John Ashburner
Journal:  Neuroimage Clin       Date:  2013-05-16       Impact factor: 4.881

6.  Characterizing aging in the human brainstem using quantitative multimodal MRI analysis.

Authors:  Christian Lambert; Rumana Chowdhury; Thomas H B Fitzgerald; Stephen M Fleming; Antoine Lutti; Chloe Hutton; Bogdan Draganski; Richard Frackowiak; John Ashburner
Journal:  Front Hum Neurosci       Date:  2013-08-20       Impact factor: 3.169

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.