Literature DB >> 15122668

Robust automated shimming technique using arbitrary mapping acquisition parameters (RASTAMAP).

L Martyn Klassen1, Ravi S Menon.   

Abstract

Quantitative MRI techniques as well as methods such as blood oxygen level-dependent (BOLD) imaging and in vivo spectroscopy require stringent optimization of magnetic field homogeneity, particularly when using high main magnetic fields. Automated shimming approaches require a method of measuring the main magnetic field, B(0), followed by adjusting the currents in resistive shim coils to maximize homogeneity. A robust automated shimming technique using arbitrary mapping acquisition parameters (RASTAMAP) using a 3D multiecho gradient echo sequence that measures B(0) with high precision was developed. Inherent compensation and postprocessing methods enable removal of artifacts due to hardware timing errors, gradient propagation delays, gradient amplifier asymmetry, and eddy currents. This allows field maps to be generated for any field of view, bandwidth, resolution, or acquisition orientation without custom tuning of sequence parameters. Field maps of an aqueous phantom show +/- 1 Hz variation with altered acquisition orientations and bandwidths. Subsequent fitting of measured shim coil field maps allows calculation of shim currents to produce optimum field homogeneity. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 15122668     DOI: 10.1002/mrm.20094

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  Cortical regions associated with autonomic cardiovascular regulation during lower body negative pressure in humans.

Authors:  Derek S Kimmerly; Deborah D O'Leary; Ravi S Menon; Joseph S Gati; J Kevin Shoemaker
Journal:  J Physiol       Date:  2005-09-08       Impact factor: 5.182

2.  Hybrid two-dimensional navigator correction: a new technique to suppress respiratory-induced physiological noise in multi-shot echo-planar functional MRI.

Authors:  Robert L Barry; L Martyn Klassen; Joy M Williams; Ravi S Menon
Journal:  Neuroimage       Date:  2007-10-11       Impact factor: 6.556

3.  Dissociating arbitrary stimulus-response mapping from movement planning during preparatory period: evidence from event-related functional magnetic resonance imaging.

Authors:  Cristiana Cavina-Pratesi; Kenneth F Valyear; Jody C Culham; Stefan Köhler; Sukhvinder S Obhi; Carlo Alberto Marzi; Melvyn A Goodale
Journal:  J Neurosci       Date:  2006-03-08       Impact factor: 6.167

4.  Origins of R2* orientation dependence in gray and white matter.

Authors:  David A Rudko; L Martyn Klassen; Sonali N de Chickera; Joseph S Gati; Gregory A Dekaban; Ravi S Menon
Journal:  Proc Natl Acad Sci U S A       Date:  2013-12-27       Impact factor: 11.205

5.  Automatic high-order shimming using parallel columns mapping (PACMAP).

Authors:  Yan Zhang; Shizhe Li; Jun Shen
Journal:  Magn Reson Med       Date:  2009-10       Impact factor: 4.668

6.  Resting-state networks show dynamic functional connectivity in awake humans and anesthetized macaques.

Authors:  R Matthew Hutchison; Thilo Womelsdorf; Joseph S Gati; Stefan Everling; Ravi S Menon
Journal:  Hum Brain Mapp       Date:  2012-03-22       Impact factor: 5.038

7.  Isoflurane induces dose-dependent alterations in the cortical connectivity profiles and dynamic properties of the brain's functional architecture.

Authors:  R Matthew Hutchison; Melina Hutchison; Kathryn Y Manning; Ravi S Menon; Stefan Everling
Journal:  Hum Brain Mapp       Date:  2014-07-12       Impact factor: 5.038

8.  Optimization of static magnetic field homogeneity in the human and animal brain in vivo.

Authors:  Kevin M Koch; Douglas L Rothman; Robin A de Graaf
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2009-02-01       Impact factor: 9.795

9.  Enhanced positive-contrast visualization of paramagnetic contrast agents using phase images.

Authors:  Parker H Mills; Eric T Ahrens
Journal:  Magn Reson Med       Date:  2009-11       Impact factor: 4.668

10.  Evaluation of preprocessing steps to compensate for magnetic field distortions due to body movements in BOLD fMRI.

Authors:  Robert L Barry; Joy M Williams; L Martyn Klassen; Jason P Gallivan; Jody C Culham; Ravi S Menon
Journal:  Magn Reson Imaging       Date:  2009-08-19       Impact factor: 2.546

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.