Retrospective motion gating in small animal CT of mice and rats.

Soenke H Bartling1, Wolfram Stiller, Michael Grasruck, Bernhard Schmidt, Peter Peschke, Wolfhard Semmler, Fabian Kiessling.   

Abstract

OBJECTIVES: Implementation and evaluation of retrospective respiratory and cardiac gating of mice and rats using a flat-panel volume-CT prototype (fpVCT).
MATERIALS AND METHODS: Respiratory and cardiac gating was implemented by equipping a fpVCT with a small animal monitoring unit. ECG and breathing excursions were recorded and 2 binary gating signals derived. Mice and rats were scanned continuously over 80 seconds after administration of blood-pool contrast media. Projections were chosen to reconstruct volumes that fall within defined phases of the cardiac/respiratory cycle.
RESULTS: Multireader analysis indicated that in gated still images motion artifacts were strongly reduced and diaphragm, tracheobronchial tract, heart, and vessels sharply delineated. From 4D series, functional data such as respiratory tidal volume and cardiac ejection fraction were calculated and matched well with values known from literature. DISCUSSION: Implementation of retrospective gating in fpVCT improves image quality and opens new perspectives for functional cardiac and lung imaging in small animals.

Entities:  

Mesh:

Year:  2007        PMID: 17984768     DOI: 10.1097/RLI.0b013e318070dcad

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  23 in total

1.  Low-dose 4D cardiac imaging in small animals using dual source micro-CT.

Authors:  M Holbrook; D P Clark; C T Badea
Journal:  Phys Med Biol       Date:  2018-01-09       Impact factor: 3.609

2.  Registration-based segmentation of murine 4D cardiac micro-CT data using symmetric normalization.

Authors:  Darin Clark; Alexandra Badea; Yilin Liu; G Allan Johnson; Cristian T Badea
Journal:  Phys Med Biol       Date:  2012-09-13       Impact factor: 3.609

3.  Prospective respiratory gated carbon nanotube micro computed tomography.

Authors:  Yueh Z Lee; Laurel M Burk; Ko-han Wang; Guohua Cao; Jonathan Volmer; Jianping Lu; Otto Zhou
Journal:  Acad Radiol       Date:  2011-03-05       Impact factor: 3.173

4.  4D micro-CT using fast prospective gating.

Authors:  Xiaolian Guo; Samuel M Johnston; Yi Qi; G Allan Johnson; Cristian T Badea
Journal:  Phys Med Biol       Date:  2012-01-07       Impact factor: 3.609

5.  Anatomical and functional imaging of myocardial infarction in mice using micro-CT and eXIA 160 contrast agent.

Authors:  Jeffrey R Ashton; Nicholas Befera; Darin Clark; Yi Qi; Lan Mao; Howard A Rockman; G Allan Johnson; Cristian T Badea
Journal:  Contrast Media Mol Imaging       Date:  2014 Mar-Apr       Impact factor: 3.161

6.  Automation process for morphometric analysis of volumetric CT data from pulmonary vasculature in rats.

Authors:  Rahul Shingrani; Gary Krenz; Robert Molthen
Journal:  Comput Methods Programs Biomed       Date:  2009-08-26       Impact factor: 5.428

7.  Bevacizumab inhibits breast cancer-induced osteolysis, surrounding soft tissue metastasis, and angiogenesis in rats as visualized by VCT and MRI.

Authors:  Tobias Bäuerle; Heidegard Hilbig; Sönke Bartling; Fabian Kiessling; Astrid Kersten; Annette Schmitt-Gräff; Hans-Ulrich Kauczor; Stefan Delorme; Martin R Berger
Journal:  Neoplasia       Date:  2008-05       Impact factor: 5.715

8.  Spectrotemporal CT data acquisition and reconstruction at low dose.

Authors:  Darin P Clark; Chang-Lung Lee; David G Kirsch; Cristian T Badea
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

9.  Comparison of 4D-microSPECT and microCT for murine cardiac function.

Authors:  Nicholas T Befera; Cristian T Badea; G Allan Johnson
Journal:  Mol Imaging Biol       Date:  2014-04       Impact factor: 3.488

Review 10.  Micro-CT of rodents: state-of-the-art and future perspectives.

Authors:  D P Clark; C T Badea
Journal:  Phys Med       Date:  2014-06-26       Impact factor: 2.685

View more