PURPOSE: We evaluated the risk of hypersensitivity to metals in a population of consecutive subjects undergoing a total knee arthroplasty (TKA). We also proposed a diagnostic pathway to address any sensitivity to metals. We finally presented the mid-term outcomes of a full non allergenic knee implant. METHODS: We developed a protocol based on the medical history, patch testing, and on specific laboratory assays, in order to assess a sensitization to metals. Twenty-four patients (25 knees) with referred or suspected allergy to metals were found in more than 1,000 treated patients, with a mean age of 72.9 years. We proceeded to a radiologic study, a clinical evaluation by the visual analogic scale (VAS), and Knee Society rating system (KSS). In all cases a full anallergic cemented implant with an oxidized zirconium femoral component and an all-polyethylene tibial baseplate was chosen. RESULTS: Four (16.6%) of the 24 patients were considered to be hypersensitive to metals. The mean follow-up was 79.2 months. No patient reported any reaction related to hypersensitivity or complications after TKA. The VAS improved from a mean preoperative value of 7.2 to 1.8 postoperatively; the KSS and the functional score increased from 38 to 91 points and from 39 to 88 points, respectively. CONCLUSIONS: We consider careful research of medical history for metals hypersensitivity crucial, and we perform patch testing and lab assays in case of doubtful sensitization. The choice of a modern hypoallergenic implant may prevent any kind of potential reactions.
PURPOSE: We evaluated the risk of hypersensitivity to metals in a population of consecutive subjects undergoing a total knee arthroplasty (TKA). We also proposed a diagnostic pathway to address any sensitivity to metals. We finally presented the mid-term outcomes of a full non allergenic knee implant. METHODS: We developed a protocol based on the medical history, patch testing, and on specific laboratory assays, in order to assess a sensitization to metals. Twenty-four patients (25 knees) with referred or suspected allergy to metals were found in more than 1,000 treated patients, with a mean age of 72.9 years. We proceeded to a radiologic study, a clinical evaluation by the visual analogic scale (VAS), and Knee Society rating system (KSS). In all cases a full anallergic cemented implant with an oxidized zirconium femoral component and an all-polyethylene tibial baseplate was chosen. RESULTS: Four (16.6%) of the 24 patients were considered to be hypersensitive to metals. The mean follow-up was 79.2 months. No patient reported any reaction related to hypersensitivity or complications after TKA. The VAS improved from a mean preoperative value of 7.2 to 1.8 postoperatively; the KSS and the functional score increased from 38 to 91 points and from 39 to 88 points, respectively. CONCLUSIONS: We consider careful research of medical history for metals hypersensitivity crucial, and we perform patch testing and lab assays in case of doubtful sensitization. The choice of a modern hypoallergenic implant may prevent any kind of potential reactions.
Authors: Nadim James Hallab; Marco Caicedo; Rachel Epstein; Kyron McAllister; Joshua J Jacobs Journal: J Biomed Mater Res A Date: 2010-02 Impact factor: 4.396
Authors: Christian Carulli; Marco Villano; Giovanni Bucciarelli; Caterina Martini; Massimo Innocenti Journal: Clin Cases Miner Bone Metab Date: 2011-05
Authors: Paritosh Gogna; Paolo Paladini; Giovanni Merolla; Carlo Alberto Augusti; De Falco Maddalena; Giuseppe Porcellini Journal: Musculoskelet Surg Date: 2016-11-30
Authors: Andrea Cozzi Lepri; Marco Giorgini; Carla Signorini; Christian Carulli; Roberto Civinini; Maria Luisa Brandi; Massimo Innocenti Journal: Clin Cases Miner Bone Metab Date: 2016-10-05
Authors: Christina M Arnholt; Daniel W MacDonald; Gregg R Klein; Harold E Cates; Clare M Rimnac; Steven M Kurtz; Sevi Kocagoz; Antonia F Chen Journal: J Arthroplasty Date: 2018-05-17 Impact factor: 4.757
Authors: Daniel Guenther; Peter Thomas; Daniel Kendoff; Mohamed Omar; Thorsten Gehrke; Carl Haasper Journal: Int Orthop Date: 2015-11-02 Impact factor: 3.075