Literature DB >> 17981664

An overview of responsive MRI contrast agents for molecular imaging.

Byunghee Yoo1, Mark D Pagel.   

Abstract

This review focuses on MR contrast agents that are responsive to a change in physiological environment. The "response" mechanisms are dependent on 6 physicochemical phenomena, including the accessibility of water to the agent, rotational tumbling time, proton exchange rate, electron spin state, MR frequency, or local field inhomogenieties caused by the agent. These phenomena can be affected by the physiological environment, including changes in concentrations or activities of proteins, enzymes, nucleic acids, metabolites, oxygen and metal ions, and changes in pH and temperature. A total of 52 examples are presented, which demonstrate the variety and creativity of different approaches used to create responsive MRI contrast agents.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 17981664     DOI: 10.2741/2796

Source DB:  PubMed          Journal:  Front Biosci        ISSN: 1093-4715


  57 in total

Review 1.  Alternatives to gadolinium-based metal chelates for magnetic resonance imaging.

Authors:  Subha Viswanathan; Zoltan Kovacs; Kayla N Green; S James Ratnakar; A Dean Sherry
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

2.  Activation of a PARACEST agent for MRI through selective outersphere interactions with phosphate diesters.

Authors:  Ching-Hui Huang; Jacob Hammell; S James Ratnakar; A Dean Sherry; Janet R Morrow
Journal:  Inorg Chem       Date:  2010-07-05       Impact factor: 5.165

3.  Fluorescent and lanthanide labeling for ligand screens, assays, and imaging.

Authors:  Jatinder S Josan; Channa R De Silva; Byunghee Yoo; Ronald M Lynch; Mark D Pagel; Josef Vagner; Victor J Hruby
Journal:  Methods Mol Biol       Date:  2011

4.  Detection of Enzyme Activity and Inhibition during Studies in Solution, In Vitro and In Vivo with CatalyCEST MRI.

Authors:  Sanhita Sinharay; Edward A Randtke; Christine M Howison; Natalia A Ignatenko; Mark D Pagel
Journal:  Mol Imaging Biol       Date:  2018-04       Impact factor: 3.488

5.  Evaluations of extracellular pH within in vivo tumors using acidoCEST MRI.

Authors:  Liu Qi Chen; Christine M Howison; Justin J Jeffery; Ian F Robey; Phillip H Kuo; Mark D Pagel
Journal:  Magn Reson Med       Date:  2013-11-26       Impact factor: 4.668

6.  Tumor-specific expression and detection of a CEST reporter gene.

Authors:  Il Minn; Amnon Bar-Shir; Keerthi Yarlagadda; Jeff W M Bulte; Paul B Fisher; Hao Wang; Assaf A Gilad; Martin G Pomper
Journal:  Magn Reson Med       Date:  2015-04-27       Impact factor: 4.668

7.  Detection of Sulfatase Enzyme Activity with a CatalyCEST MRI Contrast Agent.

Authors:  Sanhita Sinharay; Gabriela Fernández-Cuervo; Jasmine P Acfalle; Mark D Pagel
Journal:  Chemistry       Date:  2016-03-23       Impact factor: 5.236

8.  Using two chemical exchange saturation transfer magnetic resonance imaging contrast agents for molecular imaging studies.

Authors:  M Meser Ali; Guanshu Liu; Tejas Shah; Chris A Flask; Mark D Pagel
Journal:  Acc Chem Res       Date:  2009-07-21       Impact factor: 22.384

9.  Molecular imaging without radiopharmaceuticals?

Authors:  John C Gore; Thomas E Yankeelov; Todd E Peterson; Malcolm J Avison
Journal:  J Nucl Med       Date:  2009-05-14       Impact factor: 10.057

Review 10.  Detecting enzyme activities with exogenous MRI contrast agents.

Authors:  Dina V Hingorani; Byunghee Yoo; Adam S Bernstein; Mark D Pagel
Journal:  Chemistry       Date:  2014-07-02       Impact factor: 5.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.