Literature DB >> 17980534

Readout-segmented EPI for rapid high resolution diffusion imaging at 3 T.

Samantha J Holdsworth1, Stefan Skare, Rexford D Newbould, Raphael Guzmann, Nikolas H Blevins, Roland Bammer.   

Abstract

Readout mosaic segmentation has been suggested as an alternative approach to EPI for high resolution diffusion-weighted imaging (DWI). In the readout-segmented EPI (RS-EPI) scheme, segments of k-space are acquired along the readout direction. This reduces geometric distortions due to the decrease in readout time. In this work, further distortion reduction is achieved by combining RS-EPI with parallel imaging (PI). The performance of the PI-accelerated RS-EPI scheme is assessed in volunteers and patients at 3T with respect to both standard EPI and PI-accelerated EPI. Peripherally cardiac gated and non-gated RS-EPI images are acquired to assess whether motion due to brain pulsation significantly degrades the image quality. Due to the low off-resonance of PI-driven RS-EPI, we also investigate if the eddy currents induced by the diffusion gradients are low enough to use the Stejskal-Tanner diffusion preparation instead of the twice-refocused eddy-current compensated diffusion preparation to reduce TE. It is shown that non-gated phase corrected DWI performs equally as well as gated acquisitions. PI-driven DW RS-EPI images with substantially less distortion compared with single-shot EPI are shown in patients-allowing the delineation of structures in the lower parts of the brain. A twice-refocused diffusion preparation was found necessary to avoid blurring in the DWI data. This paper shows that the RS-EPI scheme may be an important alternative sampling strategy to EPI to achieve high resolution T2-weighted and diffusion-weighted images.

Entities:  

Mesh:

Year:  2007        PMID: 17980534      PMCID: PMC3360876          DOI: 10.1016/j.ejrad.2007.09.016

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  20 in total

1.  Sampling and reconstruction effects due to motion in diffusion-weighted interleaved echo planar imaging.

Authors:  D Atkinson; D A Porter; D L Hill; F Calamante; A Connelly
Journal:  Magn Reson Med       Date:  2000-07       Impact factor: 4.668

2.  On the effects of gating in diffusion imaging of the brain using single shot EPI.

Authors:  S Skare; J L Andersson
Journal:  Magn Reson Imaging       Date:  2001-10       Impact factor: 2.546

3.  Multishot diffusion-weighted FSE using PROPELLER MRI.

Authors:  James G Pipe; Victoria G Farthing; Kirsten P Forbes
Journal:  Magn Reson Med       Date:  2002-01       Impact factor: 4.668

4.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

5.  Phase insensitive preparation of single-shot RARE: application to diffusion imaging in humans.

Authors:  D C Alsop
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

6.  Tailored utilization of acquired k-space points for GRAPPA reconstruction.

Authors:  Peng Qu; Gary X Shen; Chunsheng Wang; Bing Wu; Jing Yuan
Journal:  J Magn Reson       Date:  2005-05       Impact factor: 2.229

7.  Clinical multishot DW-EPI through parallel imaging with considerations of susceptibility, motion, and noise.

Authors:  Stefan Skare; Rexford D Newbould; David B Clayton; Gregory W Albers; Scott Nagle; Roland Bammer
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

8.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application].

Authors:  J I Jackson; C H Meyer; D G Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

9.  The role of diffusion-weighted imaging in the differential diagnosis of intracranial cystic mass lesions: a report of 147 lesions.

Authors:  Jaypal Sangala Reddy; Asht Mangal Mishra; Sanjay Behari; Mazhar Husain; Vikas Gupta; Manu Rastogi; Rakesh Kumar Gupta
Journal:  Surg Neurol       Date:  2006-09

10.  MRI signal void due to in-plane motion is all-or-none.

Authors:  V J Wedeen; R M Weisskoff; B P Poncelet
Journal:  Magn Reson Med       Date:  1994-07       Impact factor: 4.668

View more
  52 in total

1.  Reduced-distortion diffusion MRI of the craniovertebral junction.

Authors:  M Iima; A Yamamoto; V Brion; T Okada; M Kanagaki; K Togashi; D Le Bihan
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-01       Impact factor: 3.825

2.  In vivo MR acoustic radiation force imaging in the porcine liver.

Authors:  Andrew B Holbrook; Pejman Ghanouni; Juan M Santos; Yoav Medan; Kim Butts Pauly
Journal:  Med Phys       Date:  2011-09       Impact factor: 4.071

3.  Optimized Diffusion-Weighting Gradient Waveform Design (ODGD) formulation for motion compensation and concomitant gradient nulling.

Authors:  Óscar Peña-Nogales; Yuxin Zhang; Xiaoke Wang; Rodrigo de Luis-Garcia; Santiago Aja-Fernández; James H Holmes; Diego Hernando
Journal:  Magn Reson Med       Date:  2018-11-05       Impact factor: 4.668

Review 4.  Advances in magnetic resonance neuroimaging.

Authors:  Michael E Moseley; Chunlei Liu; Sandra Rodriguez; Thomas Brosnan
Journal:  Neurol Clin       Date:  2009-02       Impact factor: 3.806

5.  Diffusion-weighted imaging with reverse phase-encoding polarity: the added value to the conventional diffusion-weighted imaging in differentiating acute infarctions from hyperintense brainstem artifacts.

Authors:  Gil-Sun Hong; Choong Wook Lee; Mi-Hyun Kim; Seung Won Jang; Sae Rom Chung; Ga Young Yoon; Jeong Kon Kim
Journal:  Eur Radiol       Date:  2016-05-10       Impact factor: 5.315

6.  Carpal tunnel syndrome assessment with diffusion tensor imaging: Value of fractional anisotropy and apparent diffusion coefficient.

Authors:  A S Klauser; M Abd Ellah; C Kremser; M Taljanovic; G Schmidle; M Gabl; F Cartes-Zumelzu; R Steiger; E R Gizewski
Journal:  Eur Radiol       Date:  2017-09-27       Impact factor: 5.315

7.  Differential diagnosis of nasopharyngeal carcinoma and nasopharyngeal lymphoma based on DCE-MRI and RESOLVE-DWI.

Authors:  Chengru Song; Peng Cheng; Jingliang Cheng; Yong Zhang; Mengtian Sun; Shanshan Xie; Xiaonan Zhang
Journal:  Eur Radiol       Date:  2019-08-01       Impact factor: 5.315

Review 8.  Translating preclinical MRI methods to clinical oncology.

Authors:  David A Hormuth; Anna G Sorace; John Virostko; Richard G Abramson; Zaver M Bhujwalla; Pedro Enriquez-Navas; Robert Gillies; John D Hazle; Ralph P Mason; C Chad Quarles; Jared A Weis; Jennifer G Whisenant; Junzhong Xu; Thomas E Yankeelov
Journal:  J Magn Reson Imaging       Date:  2019-03-29       Impact factor: 4.813

9.  High efficiency, low distortion 3D diffusion tensor imaging with variable density spiral fast spin echoes (3D DW VDS RARE).

Authors:  Lawrence R Frank; Youngkyoo Jung; Souheil Inati; J Michael Tyszka; Eric C Wong
Journal:  Neuroimage       Date:  2009-09-22       Impact factor: 6.556

10.  Real-time MR thermometry for monitoring HIFU ablations of the liver.

Authors:  Andrew B Holbrook; Juan M Santos; Elena Kaye; Viola Rieke; Kim Butts Pauly
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.