Literature DB >> 19950255

Real-time MR thermometry for monitoring HIFU ablations of the liver.

Andrew B Holbrook1, Juan M Santos, Elena Kaye, Viola Rieke, Kim Butts Pauly.   

Abstract

A high-resolution and high-speed pulse sequence is presented for monitoring high-intensity focused ultrasound ablations in the liver in the presence of motion. The sequence utilizes polynomial-order phase saturation bands to perform outer volume suppression, followed by spatial-spectral excitation and three readout segmented echo-planar imaging interleaves. Images are processed with referenceless thermometry to create temperature-rise images every frame. The sequence and reconstruction were implemented in RTHawk and used to image stationary and moving sonications in a polyacrylamide gel phantom (62.4 acoustic W, 50 sec, 550 kHz). Temperature-rise images were compared between moving and stationary experiments. Heating spots and corresponding temperature-rise plots matched very well. The stationary sonication had a temperature standard deviation of 0.15 degrees C compared to values of 0.28 degrees C and 0.43 degrees C measured for two manually moved sonications at different velocities. Moving the phantom (while not heating) with respect to the transducer did not cause false temperature rises, despite susceptibility changes. The system was tested on nonheated livers of five normal volunteers. The mean temperature rise was -0.05 degrees C, with a standard deviation of 1.48 degrees C. This standard deviation is acceptable for monitoring high-intensity focused ultrasound ablations, suggesting real-time imaging of moving high-intensity focused ultrasound sonications can be clinically possible.

Entities:  

Mesh:

Year:  2010        PMID: 19950255      PMCID: PMC3212435          DOI: 10.1002/mrm.22206

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  Comparison of different methods for combining phase-contrast images obtained with multiple coils.

Authors:  Per Thunberg; Matts Karlsson; Lars Wigström
Journal:  Magn Reson Imaging       Date:  2005-08-29       Impact factor: 2.546

2.  Zero filled partial fourier phase contrast MR imaging: in vitro and in vivo assessment.

Authors:  Gilberto Szarf; Yoav Dori; Dan Rettmann; Aylin Tekes; Khurram Nasir; Luciano Amado; Thomas K F Foo; David A Bluemke
Journal:  J Magn Reson Imaging       Date:  2006-01       Impact factor: 4.813

3.  Single breath-hold whole-heart MRA using variable-density spirals at 3T.

Authors:  Juan M Santos; Charles H Cunningham; Michael Lustig; Brian A Hargreaves; Bob S Hu; Dwight G Nishimura; John M Pauly
Journal:  Magn Reson Med       Date:  2006-02       Impact factor: 4.668

4.  Flexible real-time magnetic resonance imaging framework.

Authors:  Juan M Santos; Graham A Wright; John M Pauly
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2004

5.  Optimization of self-reference thermometry using complex field estimation.

Authors:  Kagayaki Kuroda; Daisuke Kokuryo; Etsuko Kumamoto; Kyohei Suzuki; Yuichiro Matsuoka; Bilgin Keserci
Journal:  Magn Reson Med       Date:  2006-10       Impact factor: 4.668

6.  Readout-segmented EPI for rapid high resolution diffusion imaging at 3 T.

Authors:  Samantha J Holdsworth; Stefan Skare; Rexford D Newbould; Raphael Guzmann; Nikolas H Blevins; Roland Bammer
Journal:  Eur J Radiol       Date:  2007-11-05       Impact factor: 3.528

Review 7.  New clinical applications of magnetic resonance-guided focused ultrasound.

Authors:  Wladyslaw Michal Gedroyc
Journal:  Top Magn Reson Imaging       Date:  2006-06

8.  Three-dimensional spatial and temporal temperature control with MR thermometry-guided focused ultrasound (MRgHIFU).

Authors:  Charles Mougenot; Bruno Quesson; Baudouin Denis de Senneville; Philippe Lourenco de Oliveira; Sara Sprinkhuizen; Jean Palussière; Nicolas Grenier; Chrit T W Moonen
Journal:  Magn Reson Med       Date:  2009-03       Impact factor: 4.668

9.  Interleaved echo-planar imaging for fast multiplanar magnetic resonance temperature imaging of ultrasound thermal ablation therapy.

Authors:  R Jason Stafford; Roger E Price; Chris J Diederich; Marko Kangasniemi; Lars E Olsson; John D Hazle
Journal:  J Magn Reson Imaging       Date:  2004-10       Impact factor: 4.813

10.  Simultaneous magnetic resonance phase and magnitude temperature maps in muscle.

Authors:  H E Cline; K Hynynen; E Schneider; C J Hardy; S E Maier; R D Watkins; F A Jolesz
Journal:  Magn Reson Med       Date:  1996-03       Impact factor: 4.668

View more
  31 in total

1.  In vivo MR acoustic radiation force imaging in the porcine liver.

Authors:  Andrew B Holbrook; Pejman Ghanouni; Juan M Santos; Yoav Medan; Kim Butts Pauly
Journal:  Med Phys       Date:  2011-09       Impact factor: 4.071

2.  Hybrid referenceless and multibaseline subtraction MR thermometry for monitoring thermal therapies in moving organs.

Authors:  William A Grissom; Viola Rieke; Andrew B Holbrook; Yoav Medan; Michael Lustig; Juan Santos; Michael V McConnell; Kim Butts Pauly
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

3.  Localized delivery of doxorubicin in vivo from polymer-modified thermosensitive liposomes with MR-guided focused ultrasound-mediated heating.

Authors:  Terence Ta; Elizabeth Bartolak-Suki; Eun-Joo Park; Kavon Karrobi; Nathan J McDannold; Tyrone M Porter
Journal:  J Control Release       Date:  2014-08-23       Impact factor: 9.776

Review 4.  MR-guided focused ultrasound surgery, present and future.

Authors:  David Schlesinger; Stanley Benedict; Chris Diederich; Wladyslaw Gedroyc; Alexander Klibanov; James Larner
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

Review 5.  Focused ultrasound surgery in oncology: overview and principles.

Authors:  Clare M C Tempany; Nathan J McDannold; Kullervo Hynynen; Ferenc A Jolesz
Journal:  Radiology       Date:  2011-04       Impact factor: 11.105

6.  Model predictive filtering MR thermometry: Effects of model inaccuracies, k-space reduction factor, and temperature increase rate.

Authors:  Henrik Odéen; Nick Todd; Christopher Dillon; Allison Payne; Dennis L Parker
Journal:  Magn Reson Med       Date:  2015-02-25       Impact factor: 4.668

7.  Histologic safety of transcranial focused ultrasound neuromodulation and magnetic resonance acoustic radiation force imaging in rhesus macaques and sheep.

Authors:  Pooja Gaur; Kerriann M Casey; Jan Kubanek; Ningrui Li; Morteza Mohammadjavadi; Yamil Saenz; Gary H Glover; Donna M Bouley; Kim Butts Pauly
Journal:  Brain Stimul       Date:  2020-02-21       Impact factor: 8.955

8.  Accurate MR thermometry by hyperpolarized 129 Xe.

Authors:  Le Zhang; Alex Burant; Andrew McCallister; Victor Zhao; Karl M Koshlap; Simone Degan; Michael Antonacci; Rosa Tamara Branca
Journal:  Magn Reson Med       Date:  2016-10-19       Impact factor: 4.668

9.  Multimodality imaging to assess immediate response to irreversible electroporation in a rat liver tumor model.

Authors:  Yue Zhang; Sarah B White; Jodi R Nicolai; Zhuoli Zhang; Derek L West; Dong-Hyun Kim; A Lee Goodwin; Frank H Miller; Reed A Omary; Andrew C Larson
Journal:  Radiology       Date:  2014-02-18       Impact factor: 11.105

Review 10.  Focal ablation of prostate cancer: four roles for magnetic resonance imaging guidance.

Authors:  Graham Sommer; Donna Bouley; Harcharan Gill; Bruce Daniel; Kim Butts Pauly; Chris Diederich
Journal:  Can J Urol       Date:  2013-04       Impact factor: 1.344

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.