Literature DB >> 17968887

Laser Doppler velocimetry (LDV) and 3D phase-contrast magnetic resonance angiography (PC-MRA) velocity measurements: validation in an anatomically accurate cerebral artery aneurysm model with steady flow.

Dorothea I Hollnagel1, Paul E Summers, Spyros S Kollias, Dimos Poulikakos.   

Abstract

PURPOSE: To verify the accuracy of velocity mapping with three-dimensional (3D) phase-contrast magnetic resonance angiography (PC-MRA) for steady flow in a realistic model of a cerebral artery aneurysm at a 3T scanner.
MATERIALS AND METHODS: Steady flow through an original geometry model of a cerebral aneurysm was mapped at characteristic positions by state-of-the-art laser Doppler velocimetry (LDV) as well as 3D PC-MRA at 3T. The spatial distributions and local values of two velocity components obtained with these two measurement methods were compared.
RESULTS: The 3D PC-MRA velocity field distribution and mean velocity values exhibited only minor differences to compare to the LDV measurements in straight artery regions for both main and secondary velocities. The differences increased in regions with disturbed flow and in cases where the measurement plane was not perpendicular to the main flow direction.
CONCLUSION: 3D PC-MRA can provide reliable measurements of velocity components of steady flow in small arteries. The accuracy of such measurements depends on the artery size and the measurement plane positioning. (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17968887     DOI: 10.1002/jmri.21179

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  9 in total

1.  Comparing velocity and fluid shear stress in a stenotic phantom with steady flow: phase-contrast MRI, particle image velocimetry and computational fluid dynamics.

Authors:  Iman Khodarahmi
Journal:  MAGMA       Date:  2014-12-12       Impact factor: 2.310

Review 2.  The mechanics of development: Models and methods for tissue morphogenesis.

Authors:  Nikolce Gjorevski; Celeste M Nelson
Journal:  Birth Defects Res C Embryo Today       Date:  2010-09

3.  Rest versus exercise hemodynamics for middle cerebral artery aneurysms: a computational study.

Authors:  T J Bowker; P N Watton; P E Summers; J V Byrne; Y Ventikos
Journal:  AJNR Am J Neuroradiol       Date:  2009-12-03       Impact factor: 3.825

4.  Comparison of hemodynamics of intracranial aneurysms between MR fluid dynamics using 3D cine phase-contrast MRI and MR-based computational fluid dynamics.

Authors:  Haruo Isoda; Yasuhide Ohkura; Takashi Kosugi; Masaya Hirano; Marcus T Alley; Roland Bammer; Norbert J Pelc; Hiroki Namba; Harumi Sakahara
Journal:  Neuroradiology       Date:  2009-12-05       Impact factor: 2.804

Review 5.  Emerging Applications of Abdominal 4D Flow MRI.

Authors:  Alejandro Roldán-Alzate; Christopher J Francois; Oliver Wieben; Scott B Reeder
Journal:  AJR Am J Roentgenol       Date:  2016-05-17       Impact factor: 3.959

6.  Experimental validation of numerical simulations on a cerebral aneurysm phantom model.

Authors:  Róbert Bordás; Santhosh Seshadhri; Gábor Janiga; Martin Skalej; Dominique Thévenin
Journal:  Interv Med Appl Sci       Date:  2012-12-27

7.  Repeatability and internal consistency of abdominal 2D and 4D phase contrast MR flow measurements.

Authors:  Andrew L Wentland; Thomas M Grist; Oliver Wieben
Journal:  Acad Radiol       Date:  2013-03-16       Impact factor: 3.173

8.  Phase-contrast magnetic resonance imaging measurements in intracranial aneurysms in vivo of flow patterns, velocity fields, and wall shear stress: comparison with computational fluid dynamics.

Authors:  Loic Boussel; Vitaliy Rayz; Alastair Martin; Gabriel Acevedo-Bolton; Michael T Lawton; Randall Higashida; Wade S Smith; William L Young; David Saloner
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

9.  Alterations in plantar vessel blood flow in patients with mild diabetic peripheral neuropathy.

Authors:  Qiang Zhou; Zhihui Qian; Maoguang Yang; Jing Liu; Jianan Wu; Luquan Ren; Lei Ren
Journal:  BMJ Open Diabetes Res Care       Date:  2022-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.