Literature DB >> 24265876

Experimental validation of numerical simulations on a cerebral aneurysm phantom model.

Róbert Bordás, Santhosh Seshadhri, Gábor Janiga, Martin Skalej, Dominique Thévenin.   

Abstract

The treatment of cerebral aneurysms, found in roughly 5% of the population and associated in case of rupture to a high mortality rate, is a major challenge for neurosurgery and neuroradiology due to the complexity of the intervention and to the resulting, high hazard ratio. Improvements are possible but require a better understanding of the associated, unsteady blood flow patterns in complex 3D geometries. It would be very useful to carry out such studies using suitable numerical models, if it is proven that they reproduce accurately enough the real conditions. This validation step is classically based on comparisons with measured data. Since in vivo measurements are extremely difficult and therefore of limited accuracy, complementary model-based investigations considering realistic configurations are essential. In the present study, simulations based on computational fluid dynamics (CFD) have been compared with in situ, laser-Doppler velocimetry (LDV) measurements in the phantom model of a cerebral aneurysm. The employed 1:1 model is made from transparent silicone. A liquid mixture composed of water, glycerin, xanthan gum and sodium chloride has been specifically adapted for the present investigation. It shows physical flow properties similar to real blood and leads to a refraction index perfectly matched to that of the silicone model, allowing accurate optical measurements of the flow velocity. For both experiments and simulations, complex pulsatile flow waveforms and flow rates were accounted for. This finally allows a direct, quantitative comparison between measurements and simulations. In this manner, the accuracy of the employed computational model can be checked.

Entities:  

Keywords:  blood-analog fluid; cerebral aneurysm; computational fluid dynamics (CFD); laser-Doppler velocimetry (LDV); phantom model

Year:  2012        PMID: 24265876      PMCID: PMC3831782          DOI: 10.1556/IMAS.4.2012.4.4

Source DB:  PubMed          Journal:  Interv Med Appl Sci        ISSN: 2061-1617


  17 in total

1.  Flow modification in canine intracranial aneurysm model by an asymmetric stent: studies using digital subtraction angiography (DSA) and image-based computational fluid dynamics (CFD) analyses.

Authors:  Yiemeng Hoi; Ciprian N Ionita; Rekha V Tranquebar; Kenneth R Hoffmann; Scott H Woodward; Dale B Taulbee; Hui Meng; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006-03-13

2.  Hemodynamic study of the anterior communicating artery.

Authors:  H Ujiie; D W Liepsch; M Goetz; R Yamaguchi; H Yonetani; K Takakura
Journal:  Stroke       Date:  1996-11       Impact factor: 7.914

3.  Characterization of cerebral aneurysms for assessing risk of rupture by using patient-specific computational hemodynamics models.

Authors:  Juan R Cebral; Marcelo A Castro; James E Burgess; Richard S Pergolizzi; Michael J Sheridan; Christopher M Putman
Journal:  AJNR Am J Neuroradiol       Date:  2005 Nov-Dec       Impact factor: 3.825

4.  Impact of stents and flow diverters on hemodynamics in idealized aneurysm models.

Authors:  Santhosh Seshadhri; Gábor Janiga; Oliver Beuing; Martin Skalej; Dominique Thévenin
Journal:  J Biomech Eng       Date:  2011-07       Impact factor: 2.097

5.  A steady flow analysis on the stented and non-stented sidewall aneurysm models.

Authors:  S C Yu; J B Zhao
Journal:  Med Eng Phys       Date:  1999-04       Impact factor: 2.242

6.  Residence times and basins of attraction for a realistic right internal carotid artery with two aneurysms.

Authors:  V D Butty; K Gudjonsson; P Buchel; V B Makhijani; Y Ventikos; D Poulikakos
Journal:  Biorheology       Date:  2002       Impact factor: 1.875

7.  Laser Doppler velocimetry (LDV) and 3D phase-contrast magnetic resonance angiography (PC-MRA) velocity measurements: validation in an anatomically accurate cerebral artery aneurysm model with steady flow.

Authors:  Dorothea I Hollnagel; Paul E Summers; Spyros S Kollias; Dimos Poulikakos
Journal:  J Magn Reson Imaging       Date:  2007-12       Impact factor: 4.813

8.  PIV-measured versus CFD-predicted flow dynamics in anatomically realistic cerebral aneurysm models.

Authors:  Matthew D Ford; Hristo N Nikolov; Jaques S Milner; Stephen P Lownie; Edwin M Demont; Wojciech Kalata; Francis Loth; David W Holdsworth; David A Steinman
Journal:  J Biomech Eng       Date:  2008-04       Impact factor: 2.097

9.  Incidence and outcome of multiple intracranial aneurysms in a defined population.

Authors:  Makio Kaminogo; Masahiro Yonekura; Shobu Shibata
Journal:  Stroke       Date:  2003-01       Impact factor: 7.914

10.  Hemodynamic stress in lateral saccular aneurysms.

Authors:  D W Liepsch; H J Steiger; A Poll; H J Reulen
Journal:  Biorheology       Date:  1987       Impact factor: 1.875

View more