| Literature DB >> 17922122 |
Hein J Verberne1, Jan B A Habraken, Berthe L F van Eck-Smit, Denis Agostini, Arnold F Jacobson.
Abstract
BACKGROUND: There is lack of validation and standardisation of acquisition parameters for myocardial (123)I-metaiodobenzylguanidine (MIBG). This lack of standardisation hampers large scale implementation of (123)I-MIBG parameters in the evaluation of patients with chronic heart failure (CHF).Entities:
Mesh:
Substances:
Year: 2007 PMID: 17922122 PMCID: PMC2275776 DOI: 10.1007/s00259-007-0611-2
Source DB: PubMed Journal: Eur J Nucl Med Mol Imaging ISSN: 1619-7070 Impact factor: 9.236
Fig. 1Example of processing procedure for late planar 123I-MIBG images. The positioning of the mediastinal ROI was standardized in relation to the lung apex, the lower boundary of the upper mediastinum and the midline between the lungs
Fig. 2Kaplan–Meier curve showing the relation between survival and time to first major cardiac event for three groups with different H/M values: late H/M <1.4 vs late H/M 1.4–2.0, p < 0.0001; late H/M<1.4 vs late H/M >2.0, p < 0.0001; late H/M 1.4–2.0 vs late H/M>2.0, p < 0.0001
Patient and scintigraphic parameters for all subjects and subdivided by late H/M 123I-MIBG
| All ( | Late H/M | |||
|---|---|---|---|---|
| <1.4 ( | 1.4–2.0 ( | >2.0 ( | ||
| Patient characteristics | ||||
| Male/Female | 237/53 | 39/12* | 117/26* | 81/15* |
| Age (years) | 53 ± 11 (21–83) | 55 ± 10‡ | 54 ± 10‡ | 49 ± 11 |
| NYHA (II/III/IV) | 165/116/9 | 11/34/6† | 85/55/3† | 69/27/0† |
| LVEF (%) | 32 ± 14 (7–85) | 23 ± 9† | 31 ± 13‡ | 39 ± 14* |
| Etiology of heart failure (isch/non-isch) | 121/169 | 20/31‡ | 70/73‡ | 31/65‡ |
| Scintigraphic parameters | ||||
| Collimator type (LEGP/LEHR/ME) | 50/216/24† | 24/25/2† | 24/104/15† | 2/87/7† |
| Activity (MBq) | 164 ± 53 (72–370) | 145 ± 31† | 173 ± 64 | 160 ± 41 |
| Delay after injection (h) | 4.3 ± 0.6 (1.9–6.9) | 4.1 ± 0.5‡ | 4.3 ± 0.5‡ | 4.5 ± 0.6 |
| Duration of acquisition (min) | 9.6 ± 3.3 (1–15) | 11.3 ± 4.3† | 9.2 ± 3.4 | 9.4 ± 2.0* |
Data are presented as mean ± standard deviation (range).
NYHA New York Heart Association, LVEF left ventricular ejection fraction, Isch ischemic, Non-isch non-ischemic, LEGP low-energy all purpose, LEHR low-energy high resolution, ME medium energy, MBq mega-Becquerel, h hours, min minutes.
Categorical data (Fisher’s exact test, for each group): *p = 0.53; †p < 0.001; ‡p < 0.035.
Continuous data (ANOVA with posthoc Bonferoni): *p < 0.01 compared to late H/M <1.4; †p < 0.01 compared to late H/M 1.4–2.0; ‡p < 0.01 compared to late H/M >2.0.
Multivariate analysis of clinical and acquisition related parameters as predictors of late H/M for all subjects (N = 290)
| Variables | Coefficient | Standard error | |
|---|---|---|---|
| Constant | 0.549 | 0.411 | |
| LVEF | 0.015 | 0.02 | <0.001 |
| Collimator type | 0.531 | 0.087 | <0.001 |
| Duration of acquisition | 0.045 | 0.014 | 0.001 |
| NYHA | −0.121 | 0.055 | 0.028 |
| Age | −0.006 | 0.003 | 0.034 |
Goodness-of-fit of the model: adjusted R2 = 0.312; P value = <0.0001
Multivariate analysis of clinical and acquisition related parameters as predictors of late H/M for subjects with a late H/M<1.4 (N = 51)
| Variables | Coefficient | Standard error | |
|---|---|---|---|
| Constant | 1.680 | 0.161 | |
| NYHA | −0.055 | 0.027 | 0.049 |
| Delay after injection | −0.068 | 0.030 | 0.031 |
Goodness-of-fit of the model: adjusted R2 = 0.104; P value = 0.030
Multivariate analysis of clinical and acquisition related parameters as predictors of late H/M for subjects with a late H/M 1.4–2.0 (N = 143)
| Variables | Coefficient | Standard error | |
|---|---|---|---|
| Constant | 1.370 | 0.078 | |
| LVEF | 0.004 | 0.001 | 0.001 |
| Collimator type | 0.086 | 0.030 | 0.005 |
Goodness-of-fit of the model: adjusted R2 = 0.100; P value = 0.001
Multivariate analysis of clinical and acquisition related parameters as predictors of late H/M for subjects with a late H/M >2.0 (N = 96)
| Variables | Coefficient | Standard error | P value |
|---|---|---|---|
| Constant | 0.022 | 1.376 | |
| Duration of acquisition | 0.119 | 0.057 | 0.040 |
Goodness-of-fit of the model: adjusted R2 = 0.013; P value = 0.347