Literature DB >> 14668774

Effect of collimator choice on quantitative assessment of cardiac iodine 123 MIBG uptake.

Yusuke Inoue1, Akira Suzuki, Ichiro Shirouzu, Toru Machida, Yasunori Yoshizawa, Fumihide Akita, Satoshi Ohnishi, Kohki Yoshikawa, Kuni Ohtomo.   

Abstract

BACKGROUND: Quantitative accuracy in iodine 123 studies may be impaired by septal penetration. We evaluated the effect of collimator choice on estimation of the heart-to-mediastinum (H/M) ratio in cardiac I-123 metaiodobenzylguanidine (MIBG) imaging. METHODS AND
RESULTS: A low-energy high-resolution (LEHR) collimator, special LEHR (SLEHR) collimator, and medium-energy (ME) collimator were used. In experiments in which a phantom of simple geometry was used, the use of the LEHR collimator provided the lowest contrast accuracy, suggesting the effect of septal penetration. Thoracic phantom studies demonstrated contamination of heart and mediastinum counts by lung and liver activities, which was greatest with the LEHR collimator and least with the ME collimator. In 8 patients anterior chest views were acquired successively with the three collimators after I-123 MIBG injection. H/M ratios were significantly higher with the SLEHR collimator than with the LEHR collimator and were still higher with the ME collimator. The difference in H/M ratios between the LEHR and ME collimators showed a high positive correlation with the lung-to-mediastinum ratio.
CONCLUSIONS: Collimator choice substantially influences estimation of the H/M ratios in cardiac I-123 MIBG imaging. The use of an ME collimator provides high quantitative accuracy and may enhance reliability in the evaluation of cardiac sympathetic nerve function.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14668774     DOI: 10.1016/s1071-3581(03)00652-4

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  16 in total

Review 1.  Metaiodobenzylguanidine scintigraphy of the heart: what have we learnt clinically?

Authors:  N Hattori; M Schwaiger
Journal:  Eur J Nucl Med       Date:  2000-01

2.  Detection of doxorubicin cardiotoxicity by using iodine-123 BMIPP early dynamic SPECT: quantitative evaluation of early abnormality of fatty acid metabolism with the Rutland method.

Authors:  K Saito; K Takeda; S Okamoto; R Okamoto; K Makino; Y Tameda; Y Nomura; H Maeda; T Ichihara; T Nakano
Journal:  J Nucl Cardiol       Date:  2000 Nov-Dec       Impact factor: 5.952

3.  [Scatter correction in myocardial thallium SPECT: needs for optimization of energy window settings in the energy window-based scatter correction techniques].

Authors:  Y Narita; H Iida
Journal:  Kaku Igaku       Date:  1999-02

Review 4.  MIBG imaging.

Authors:  Amar D Patel; Ami E Iskandrian
Journal:  J Nucl Cardiol       Date:  2002 Jan-Feb       Impact factor: 5.952

5.  Simultaneous acquisition of iodine-123 emission and technetium-99m transmission data for quantitative brain single-photon emission tomographic imaging.

Authors:  K Ogasawara; J Hashimoto; K Ogawa; A Kubo; N Motomura; H Hasegawa; T Ichihara
Journal:  Eur J Nucl Med       Date:  1998-11

6.  Comparison of low- and medium-energy collimators for SPECT imaging with iodine-123-labeled antibodies.

Authors:  D J Macey; G L DeNardo; S J DeNardo; H H Hines
Journal:  J Nucl Med       Date:  1986-09       Impact factor: 10.057

7.  Compton scatter compensation using the triple-energy window method for single- and dual-isotope SPECT.

Authors:  T Ichihara; K Ogawa; N Motomura; A Kubo; S Hashimoto
Journal:  J Nucl Med       Date:  1993-12       Impact factor: 10.057

Review 8.  Scatter correction in scintigraphy: the state of the art.

Authors:  I Buvat; H Benali; A Todd-Pokropek; R Di Paola
Journal:  Eur J Nucl Med       Date:  1994-07

9.  Effects of scatter and attenuation correction on quantitative analysis of beta-CIT brain SPET.

Authors:  J Hashimoto; T Sasaki; K Ogawa; A Kubo; N Motomura; T Ichihara; T Amano; Y Fukuuchi
Journal:  Nucl Med Commun       Date:  1999-02       Impact factor: 1.690

10.  Therapeutic effect of co-enzyme Q10 on idiopathic dilated cardiomyopathy: assessment by iodine-123 labelled 15-(p-iodophenyl)-3(R,S)-methylpentadecanoic acid myocardial single-photon emission tomography.

Authors:  Y Kim; Y Sawada; G Fujiwara; H Chiba; T Nishimura
Journal:  Eur J Nucl Med       Date:  1997-06
View more
  31 in total

1.  Collimator choice in cardiac SPECT with I-123-labeled tracers.

Authors:  Yusuke Inoue; Ichiro Shirouzu; Toru Machida; Yasunori Yoshizawa; Fumihide Akita; Manabu Minami; Kuni Ohtomo
Journal:  J Nucl Cardiol       Date:  2004 Jul-Aug       Impact factor: 5.952

2.  A step forward in the use of SPECT imaging with I-123 MIBG.

Authors:  Mouhamad Abdallah; Myron C Gerson
Journal:  J Nucl Cardiol       Date:  2012-02       Impact factor: 5.952

3.  Standardization of metaiodobenzylguanidine heart to mediastinum ratio using a calibration phantom: effects of correction on normal databases and a multicentre study.

Authors:  Kenichi Nakajima; Koichi Okuda; Shinro Matsuo; Mitsuhiro Yoshita; Junichi Taki; Masahito Yamada; Seigo Kinuya
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-10-19       Impact factor: 9.236

4.  Influence of collimator choice and simulated clinical conditions on 123I-MIBG heart/mediastinum ratios: a phantom study.

Authors:  Hein J Verberne; Christel Feenstra; W Matthijs de Jong; G Aernout Somsen; Berthe L F van Eck-Smit; Ellinor Busemann Sokole
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-05-18       Impact factor: 9.236

5.  Optimized acquisition and processing protocols for I-123 cardiac SPECT imaging.

Authors:  Ji Chen; Ernest V Garcia; James R Galt; Russell D Folks; Ignasi Carrio
Journal:  J Nucl Cardiol       Date:  2006 Mar-Apr       Impact factor: 5.952

6.  How to use myocardial 123I-MIBG scintigraphy in chronic heart failure.

Authors:  Denis Agostini; Ignasi Carrio; Hein J Verberne
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-04       Impact factor: 9.236

7.  123I-mIBG and the phantom tollbooth.

Authors:  Albert Flotats; Ignasi Carrió
Journal:  J Nucl Cardiol       Date:  2017-03-13       Impact factor: 5.952

8.  ASNC imaging guidelines for SPECT nuclear cardiology procedures: Stress, protocols, and tracers.

Authors:  Milena J Henzlova; W Lane Duvall; Andrew J Einstein; Mark I Travin; Hein J Verberne
Journal:  J Nucl Cardiol       Date:  2016-06       Impact factor: 5.952

9.  Significance of cardiac sympathetic nervous system abnormality for predicting vascular events in patients with idiopathic paroxysmal atrial fibrillation.

Authors:  Yasushi Akutsu; Kyouichi Kaneko; Yusuke Kodama; Hui-Ling Li; Jumpei Suyama; Akira Shinozuka; Takehiko Gokan; Mitsuharu Kawamura; Taku Asano; Yuji Hamazaki; Kaoru Tanno; Youichi Kobayashi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-12-17       Impact factor: 9.236

10.  Standardization of the heart-to-mediastinum ratio of 123I-labelled-metaiodobenzylguanidine uptake using the dual energy window method: feasibility of correction with different camera-collimator combinations.

Authors:  Shinro Matsuo; Kenichi Nakajima; Koichi Okuda; Masaya Kawano; Takehiro Ishikawa; Tetsuo Hosoya; Junichi Taki; Seigo Kinuya
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-11-07       Impact factor: 9.236

View more