Literature DB >> 17909614

Traceability, reference systems and result comparability.

Mauro Panteghini1.   

Abstract

The standardisation of measurements is of high priority in laboratory medicine, its purpose being to achieve closer comparability of results obtained using routine measurement procedures. At present, there is international cooperation in developing reference measurement systems (reference methods, reference materials, and reference laboratory networks) for analytes of clinical significance. These reference systems will reduce, wherever possible, measurement uncertainty and promote the comparability of results. The implementation of measurement traceability through the reference system provides one of the most important tools that supports the standardisation process in laboratory medicine. It aims to achieve result comparability regardless of the measurement procedure (test kit) and the clinical laboratory where analyses are carried out. The aim of this review is to discuss some concepts related to the achievement of standardisation by the implementation of a metrologically-correct measurement system and to provide some examples that illustrate the complexity of this approach and the impact of these activities on patient care.

Entities:  

Year:  2007        PMID: 17909614      PMCID: PMC1994107     

Source DB:  PubMed          Journal:  Clin Biochem Rev        ISSN: 0159-8090


  35 in total

Review 1.  Establishing a reference system in clinical enzymology.

Authors:  M Panteghini; F Ceriotti; G Schumann; L Siekmann
Journal:  Clin Chem Lab Med       Date:  2001-09       Impact factor: 3.694

Review 2.  Development of a reference system for the international standardization of HbA1c/glycohemoglobin determinations.

Authors:  W Hoelzel; K Miedema
Journal:  J Int Fed Clin Chem       Date:  1996-06

3.  Standardization of HbA1c and Optimal Range of Monitoring.

Authors:  Kor Miedema
Journal:  Scand J Clin Lab Invest Suppl       Date:  2005

4.  Why commutability matters.

Authors:  W Greg Miller; Gary L Myers; Robert Rej
Journal:  Clin Chem       Date:  2006-04       Impact factor: 8.327

5.  The importance of metrological traceability on the validity of creatinine measurement as an index of renal function.

Authors:  Mauro Panteghini; Gary L Myers; W Greg Miller; Neil Greenberg
Journal:  Clin Chem Lab Med       Date:  2006       Impact factor: 3.694

6.  Impact of reference materials on accuracy in clinical chemistry.

Authors:  C Franzini; F Ceriotti
Journal:  Clin Biochem       Date:  1998-08       Impact factor: 3.281

7.  How useful are reference materials?

Authors:  G Miller
Journal:  Clin Chem       Date:  1996-11       Impact factor: 8.327

8.  Accuracy in clinical chemistry--does anybody care?

Authors:  N W Tietz
Journal:  Clin Chem       Date:  1994-06       Impact factor: 8.327

9.  Creatinine measurement: state of the art in accuracy and interlaboratory harmonization.

Authors:  W Greg Miller; Gary L Myers; Edward R Ashwood; Anthony A Killeen; Edward Wang; Linda M Thienpont; Lothar Siekmann
Journal:  Arch Pathol Lab Med       Date:  2005-03       Impact factor: 5.534

10.  Pilot external quality assessment survey for post-market vigilance of in vitro diagnostic medical devices and investigation of trueness of participants' results.

Authors:  Linda M Thienpont; Dietmar Stöckl; Josef Kratochvíla; Bedrich Friedecký; Marek Budina
Journal:  Clin Chem Lab Med       Date:  2003-02       Impact factor: 3.694

View more
  15 in total

1.  Traceability of measurement results.

Authors:  George Koumantakis
Journal:  Clin Biochem Rev       Date:  2008-08

2.  Traceability in clinical enzymology.

Authors:  Ilenia Infusino; Roberto Bonora; Mauro Panteghini
Journal:  Clin Biochem Rev       Date:  2007-11

3.  Standardisation--the theory and the practice.

Authors:  Jill Tate; Mauro Panteghini
Journal:  Clin Biochem Rev       Date:  2007-11

Review 4.  Harmonization of Liquid Chromatography-Tandem Mass Spectrometry Protein Assays.

Authors:  Alan L Rockwood; Mark S Lowenthal; Cory Bystrom
Journal:  Clin Lab Med       Date:  2018-09       Impact factor: 1.935

5.  Harmonisation of laboratory testing.

Authors:  Jillian R Tate; Roger Johnson; Michael Legg
Journal:  Clin Biochem Rev       Date:  2012-08

6.  Candidate reference measurement procedure based on HPAEC-PAD for the development of certified reference materials for monosaccharides in serum.

Authors:  Min-Seon Seo; Ji-Seon Jeong; Mariam M Abady; Ha-Jeong Kwon
Journal:  Anal Bioanal Chem       Date:  2021-07-20       Impact factor: 4.142

7.  Biochemical markers in the follow-up of the osteoporotic patients.

Authors:  Alessandro Terreni; Paola Pezzati
Journal:  Clin Cases Miner Bone Metab       Date:  2012-09-30

Review 8.  Markers of bone turnover for the prediction of fracture risk and monitoring of osteoporosis treatment: a need for international reference standards.

Authors:  S Vasikaran; R Eastell; O Bruyère; A J Foldes; P Garnero; A Griesmacher; M McClung; H A Morris; S Silverman; T Trenti; D A Wahl; C Cooper; J A Kanis
Journal:  Osteoporos Int       Date:  2010-12-24       Impact factor: 4.507

9.  Development of an LC-MS/MS Proposed Candidate Reference Method for the Standardization of Analytical Methods to Measure Lipoprotein(a).

Authors:  Santica M Marcovina; Noémie Clouet-Foraison; Marlys L Koschinsky; Mark S Lowenthal; Allen Orquillas; Michael B Boffa; Andrew N Hoofnagle; Tomáš Vaisar
Journal:  Clin Chem       Date:  2021-03-01       Impact factor: 12.167

10.  Clinical evaluation of analytical variations in serum creatinine measurements: why laboratories should abandon Jaffe techniques.

Authors:  Iefke Drion; Christa Cobbaert; Klaas H Groenier; Cas Weykamp; Henk J G Bilo; Jack F M Wetzels; Nanne Kleefstra
Journal:  BMC Nephrol       Date:  2012-10-08       Impact factor: 2.388

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.