Literature DB >> 34286356

Candidate reference measurement procedure based on HPAEC-PAD for the development of certified reference materials for monosaccharides in serum.

Min-Seon Seo1,2, Ji-Seon Jeong1,3, Mariam M Abady1,3,4, Ha-Jeong Kwon5.   

Abstract

To achieve the measurement reliability of monosaccharides used as diagnostic markers in clinical fields, it is essential to establish certified reference materials (CRMs). The purpose of this study is to develop a serum CRM by adopting high-performance anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD) as a new candidate reference measurement procedure for the measurement of glucose and galactose, common diagnostic markers of diabetes and galactosemia, respectively. Using various monosaccharides as internal standards, the accuracy of the HPAEC-PAD method was tested by measuring glucose CRM following treatment with three different deproteinization methods: ultrafiltration, protein precipitation by trichloroacetic acid (TCA), and protein precipitation by acetonitrile. Results showed that ultrafiltration and 5% TCA provided good accuracy with every tested monosaccharide as the internal standard. Accordingly, serum samples in this study were treated by ultrafiltration after adding 2-deoxy-D-glucose and arabinose, which were selected as internal standards for galactose and glucose, respectively. Both intra- and inter-day recovery tests showed good precision and accuracy within 2%. From the serum CRM batches prepared at two levels, 11 units were analyzed by exact-matched calibration methods, and the mass fractions of galactose and glucose were determined via HPAEC-PAD. The between-unit relative standard deviations were not more than 1.5%, showing homogeneity. The expanded uncertainties (%) of galactose and glucose for both levels were less than 3.6% and 2.3% at 95% confidence. The HPAEC-PAD method presented in this study can significantly improve the accuracy and precision of simultaneous monosaccharide analysis, allowing for the development of further serum CRMs for monosaccharides. Graphical abstract.
© 2021. Springer-Verlag GmbH Germany, part of Springer Nature.

Entities:  

Keywords:  Certified reference materials (CRMs); High-performance anion-exchange chromatography with pulsed amperometric detection; Monosaccharide; Reference measurement procedure

Year:  2021        PMID: 34286356     DOI: 10.1007/s00216-021-03537-8

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  12 in total

1.  High accuracy analysis of glucose in human serum by isotope dilution liquid chromatography-tandem mass spectrometry.

Authors:  Yizhao Chen; Qinde Liu; Sharon Yong; Tong Kooi Lee
Journal:  Clin Chim Acta       Date:  2012-01-27       Impact factor: 3.786

2.  Development of a new diagnostic method for galactosemia by high-performance anion-exchange chromatography with pulsed amperometric detection.

Authors:  Ji-Seon Jeong; Hye-Ran Yoon; Seon-Pyo Hong
Journal:  J Chromatogr A       Date:  2006-12-11       Impact factor: 4.759

3.  Traceability, reference systems and result comparability.

Authors:  Mauro Panteghini
Journal:  Clin Biochem Rev       Date:  2007-08

4.  Reference materials and reference measurement procedures: an overview from a national metrology institute.

Authors:  David M Bunk
Journal:  Clin Biochem Rev       Date:  2007-11

5.  Determination of serum glucose by isotope dilution liquid chromatography-tandem mass spectrometry: a candidate reference measurement procedure.

Authors:  Tianjiao Zhang; Chuanbao Zhang; Haijian Zhao; Jie Zeng; Jiangtao Zhang; Weiyan Zhou; Ying Yan; Yufei Wang; Mo Wang; Wenxiang Chen
Journal:  Anal Bioanal Chem       Date:  2016-08-01       Impact factor: 4.142

6.  Enhancing the accuracy of measurement of small molecule organic biomarkers.

Authors:  Tang Lin Teo; Katrice A Lippa; Lindsey Mackay; Sharon Yong; Qinde Liu; Johanna E Camara; Vincent Delatour; Tong Kooi Lee; Béatrice Lalere; Gavin O' Connor; André Henrion; Megumi Kato; Masahiko Numata; Ha-Jeong Kwon; Ji-Seon Jeong; Bei Xu; Dewei Song; Jintana Nammoonnoy; Wagner Wollinger
Journal:  Anal Bioanal Chem       Date:  2019-10-30       Impact factor: 4.142

7.  Markedly increased serum and urinary fructose concentrations in diabetic patients with ketoacidosis or ketosis.

Authors:  Takahiro Kawasaki; Kanji Igarashi; Nobuyuki Ogata; Yoko Oka; Kaoru Ichiyanagi; Toshikazu Yamanouchi
Journal:  Acta Diabetol       Date:  2010-03-03       Impact factor: 4.280

8.  Improvement of sugar analysis sensitivity using anion-exchange chromatography-electrospray ionization mass spectrometry with sheath liquid interface.

Authors:  Xian-Bing Xu; Ding-Bo Liu; Xiao Ming Guo; Shu-Juan Yu; Pei Yu
Journal:  J Chromatogr A       Date:  2014-09-16       Impact factor: 4.759

9.  Plasma Mannose Levels Are Associated with Incident Type 2 Diabetes and Cardiovascular Disease.

Authors:  Adil Mardinoglu; Alena Stančáková; Luca A Lotta; Johanna Kuusisto; Jan Boren; Matthias Blüher; Nicholas J Wareham; Ele Ferrannini; Per Henrik Groop; Markku Laakso; Claudia Langenberg; Ulf Smith
Journal:  Cell Metab       Date:  2017-08-01       Impact factor: 27.287

10.  Screening for galactosemia: is there a place for it?

Authors:  Magd A Kotb; Lobna Mansour; Radwa A Shamma
Journal:  Int J Gen Med       Date:  2019-05-23
View more
  1 in total

1.  Development of Certified Reference Material for Amino Acids in Dried Blood Spots and Accuracy Assessment of Disc Sampling.

Authors:  Sangji Woo; Nordiana Rosli; Seohyun Choi; Ha-Jeong Kwon; Young Ahn Yoon; Sunhyun Ahn; Ji Youn Lee; Seon-Pyo Hong; Ji-Seon Jeong
Journal:  Anal Chem       Date:  2022-07-08       Impact factor: 8.008

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.