Abstract

CONTEXT: The National Kidney Disease Education Program recommends calculating glomerular filtration rate from serum creatinine concentration. Accurate creatinine measurements are necessary for this calculation.
OBJECTIVE: To evaluate the state of the art in measuring serum creatinine, as well as the ability of a proficiency testing program to measure bias for individual laboratories and method peer groups.
DESIGN: A fresh-frozen, off-the-clot pooled serum specimen plus 4 conventional specimens were sent to participants in the College of American Pathologists Chemistry Survey for assay of creatinine. Creatinine concentrations were assigned by isotope dilution mass spectrometry reference measurement procedures. PARTICIPANTS: Clinical laboratories with an acceptable result for all 5 survey specimens (n = 5624).
RESULTS: The fresh frozen serum (FFS) specimen had a creatinine concentration of 0.902 mg/dL (79.7 micromol/L). Mean bias for 50 instrument-method peer groups varied from -0.06 to 0.31 mg/dL (-5.3 to 27.4 micromol/L), with 30 (60%) of 50 peer groups having significant bias (P < .001). The bias variability was related to instrument manufacturer (P < or = .001) rather than method type (P = .02) with 24 (63%) of 38 alkaline picric acid methods and with 6 (50%) of 12 enzymatic methods having significant biases. Two conventional specimens had creatinine concentrations of 0.795 and 2.205 mg/dL (70.3 and 194.9 micromol/L) and had apparent survey biases significantly different (P < .001) from that of the FFS specimen for 34 (68%) and 35 (70%) of 50 peer groups, respectively.
CONCLUSIONS: Thirty of 50 peer groups had significant bias for creatinine. Bias was primarily associated with instrument manufacturer, not with type of method used. Proficiency testing using a commutable specimen measured participant bias versus a reference measurement procedure and provided trueness surveillance of instrument-method peer groups.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15737021     DOI: 10.5858/2005-129-297-CMSOTA

Source DB:  PubMed          Journal:  Arch Pathol Lab Med        ISSN: 0003-9985            Impact factor:   5.534


  43 in total

1.  Imprecision of urinary iothalamate clearance as a gold-standard measure of GFR decreases the diagnostic accuracy of kidney function estimating equations.

Authors:  Yuen-Ting Diana Kwong; Lesley A Stevens; Elizabeth Selvin; Yaping Lucy Zhang; Tom Greene; Frederick Van Lente; Andrew S Levey; Josef Coresh
Journal:  Am J Kidney Dis       Date:  2010-07       Impact factor: 8.860

Review 2.  Kidney Failure and Liver Allocation: Current Practices and Potential Improvements.

Authors:  Varun Saxena; Jennifer C Lai
Journal:  Adv Chronic Kidney Dis       Date:  2015-09       Impact factor: 3.620

Review 3.  Essentials of laboratory medicine for the nephrology clinician.

Authors:  Tarak Srivastava; Uttam Garg; Y Raymond Chan; Uri S Alon
Journal:  Pediatr Nephrol       Date:  2006-09-01       Impact factor: 3.714

4.  Measurement of serum creatinine--current status and future goals.

Authors:  Michael Peake; Malcolm Whiting
Journal:  Clin Biochem Rev       Date:  2006-11

5.  Traceability, reference systems and result comparability.

Authors:  Mauro Panteghini
Journal:  Clin Biochem Rev       Date:  2007-08

6.  Modification of Jaffe's kinetic method decreases bilirubin interference: A preliminary report.

Authors:  R Vaishya; Sarika Arora; B Singh; V Mallika
Journal:  Indian J Clin Biochem       Date:  2010-02-10

7.  Age-dependent error in creatinine clearance estimated by Cockcroft-Gault equation for the elderly patients in a Japanese hospital: a cross-sectional study.

Authors:  Mitsuhiro Matsuo; Fuminori Yamagishi
Journal:  J Anesth       Date:  2019-01-02       Impact factor: 2.078

8.  Albuminuria, cognitive functioning, and white matter hyperintensities in homebound elders.

Authors:  Daniel E Weiner; Keith Bartolomei; Tammy Scott; Lori Lyn Price; John L Griffith; Irwin Rosenberg; Andrew S Levey; Marshal F Folstein; Mark J Sarnak
Journal:  Am J Kidney Dis       Date:  2008-12-12       Impact factor: 8.860

9.  Iterative Outlier Removal: A Method for Identifying Outliers in Laboratory Recalibration Studies.

Authors:  Christina M Parrinello; Morgan E Grams; Yingying Sang; David Couper; Lisa M Wruck; Danni Li; John H Eckfeldt; Elizabeth Selvin; Josef Coresh
Journal:  Clin Chem       Date:  2016-05-19       Impact factor: 8.327

10.  Comparison of chronic kidney disease prevalence examined by the chronic kidney disease epidemiology collaboration equation with that by the modification of diet in renal disease equation in Korean adult population.

Authors:  Sang-Yong Shin; Min-Jung Kwon; Hyosoon Park; Hee-Yeon Woo
Journal:  J Clin Lab Anal       Date:  2014-02-27       Impact factor: 2.352

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.