Literature DB >> 11601675

Establishing a reference system in clinical enzymology.

M Panteghini1, F Ceriotti, G Schumann, L Siekmann.   

Abstract

The goal of standardization for measurements of catalytic concentrations of enzymes is to achieve comparable results in human samples, independent of the reagent kits, instruments and laboratory where the procedure is carried out. To pursue this objective, the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has launched a project to establish a reference system in clinical enzymology. This system is based on three hinges: a) extensively evaluated and carefully described reference procedures, b) certified reference materials and c) a network of reference laboratories operating in a highly controlled manner. The original IFCC-recommended procedures for alanine aminotransferase, aspartate aminotransferase, creatine kinase, gamma-glutamyltransferase, lactate dehydrogenase and alpha-amylase have been slightly modified to optimize them at 37 degrees C, with the definition of detailed operating procedures. A group of laboratories perform these procedures manually, with self-made reagents on carefully calibrated instruments. Partially purified and stabilized materials, prepared in the past by the Community Bureau of Reference, have been re-certified by these laboratories for alanine aminotransferase, creatine kinase, gamma-glutamyltransferase and lactate dehydrogenase activities. Using these materials and the manufacturer's standing procedures, industry can assign traceable values to commercial calibrators. Thus, clinical laboratories, which will use routine procedures with these validated calibrators to measure human specimens, can finally obtain values which are traceable to reference procedures.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11601675     DOI: 10.1515/CCLM.2001.131

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  5 in total

1.  Traceability, reference systems and result comparability.

Authors:  Mauro Panteghini
Journal:  Clin Biochem Rev       Date:  2007-08

2.  Traceability in clinical enzymology.

Authors:  Ilenia Infusino; Roberto Bonora; Mauro Panteghini
Journal:  Clin Biochem Rev       Date:  2007-11

3.  Serum alanine aminotransferase is correlated with hematocrit in healthy human subjects.

Authors:  Yun Hu; Soren Snitker; Kathleen A Ryan; Rongze Yang; Braxton D Mitchell; Alan R Shuldiner; Dalong Zhu; Da-Wei Gong
Journal:  Scand J Clin Lab Invest       Date:  2012-05       Impact factor: 1.713

Review 4.  Nanosilica-from medicine to pest control.

Authors:  T K Barik; B Sahu; V Swain
Journal:  Parasitol Res       Date:  2008-04-29       Impact factor: 2.289

5.  Standardization in Clinical Enzymology.

Authors:  Ilenia Infusino; Panteghini Mauro
Journal:  EJIFCC       Date:  2009-10-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.