Literature DB >> 25638514

Agreement between stroke volume measured by oesophageal Doppler and uncalibrated pulse contour analysis during fluid loads in severe aortic stenosis.

Lars Øivind Høiseth1, Ingrid Elise Hoff, Ove Andreas Hagen, Svein Aslak Landsverk, Knut Arvid Kirkebøen.   

Abstract

The purpose of this analysis was to study agreement and trending of stroke volume measured by oesophageal Doppler and 3rd generation Vigileo during fluid loads in patients with severe aortic stenosis. Observational study in 32 patients (30 analyzed) scheduled for aortic valve replacement due to severe aortic stenosis. After induction of anesthesia and before start of surgery, hemodynamic registrations for 1 min were obtained before and after a fluid load. Agreement between stroke volume measured by oesophageal Doppler (SVOD) and Vigileo (SVVig) was evaluated in Bland-Altman plot and trending in four-quadrant and polar plots. Bias ± limits of agreement (LOA) between SVOD and SVVig was 24 ± 37 ml (percentage error 45%). Concordance of the two methods from before to after a fluid load was 100%. Angular bias ± LOA was 12° ± 28°. Absolute values of SVOD and SVVig agreed poorly, but changes were highly concordant during fluid loads in aortic stenosis patients. The angular agreement indicated acceptable trending. The two measurement methods are not interchangeable in patients with aortic stenosis.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25638514     DOI: 10.1007/s10877-015-9666-y

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  23 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  Computer simulation of arterial flow with applications to arterial and aortic stenoses.

Authors:  N Stergiopulos; D F Young; T R Rogge
Journal:  J Biomech       Date:  1992-12       Impact factor: 2.712

Review 3.  A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output.

Authors:  Lester A Critchley; Anna Lee; Anthony M-H Ho
Journal:  Anesth Analg       Date:  2010-08-24       Impact factor: 5.108

4.  Echocardiographic assessment of aortic elastic properties with automated border detection in an ICU: in vivo application of the arctangent Langewouters model.

Authors:  Jan R Heerman; Patrick Segers; Carl D Roosens; Frank Gasthuys; Pascal R Verdonck; Jan I Poelaert
Journal:  Am J Physiol Heart Circ Physiol       Date:  2004-12-16       Impact factor: 4.733

5.  The impact of systemic vascular resistance on the accuracy of the FloTrac/Vigileo™ system in the perioperative period of cardiac surgery: a prospective observational comparison study.

Authors:  Yohei Sotomi; Katsuomi Iwakura; Yoshiharu Higuchi; Kazuo Abe; Junko Yoshida; Takafumi Masai; Kenshi Fujii
Journal:  J Clin Monit Comput       Date:  2013-06-08       Impact factor: 2.502

6.  Lithium dilution cardiac output measurement in the critically ill patient: determination of precision of the technique.

Authors:  M Cecconi; D Dawson; R M Grounds; A Rhodes
Journal:  Intensive Care Med       Date:  2008-09-18       Impact factor: 17.440

Review 7.  Edwards FloTrac sensor and Vigileo monitor: easy, accurate, reliable cardiac output assessment using the arterial pulse wave.

Authors:  Gerard R Manecke
Journal:  Expert Rev Med Devices       Date:  2005-09       Impact factor: 3.166

8.  Oesophageal Doppler and calibrated pulse contour analysis are not interchangeable within a goal-directed haemodynamic algorithm in major gynaecological surgery.

Authors:  A Feldheiser; O Hunsicker; H Krebbel; K Weimann; L Kaufner; K-D Wernecke; C Spies
Journal:  Br J Anaesth       Date:  2014-08-08       Impact factor: 9.166

9.  Dynamic variables and fluid responsiveness in patients for aortic stenosis surgery.

Authors:  L Ø Høiseth; I E Hoff; O A Hagen; S A Landsverk; K A Kirkebøen
Journal:  Acta Anaesthesiol Scand       Date:  2014-04-29       Impact factor: 2.105

10.  Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform.

Authors:  Suraphong Lorsomradee; Sratwadee Lorsomradee; Stefanie Cromheecke; Stefan G De Hert
Journal:  J Cardiothorac Vasc Anesth       Date:  2007-05-07       Impact factor: 2.628

View more
  3 in total

Review 1.  Journal of Clinical Monitoring and Computing 2015 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Karim Bendjelid; Steffen Rex; Thomas Scheeren; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2016-02-12       Impact factor: 2.502

2.  Cardiac output monitoring in severe aortic stenosis: Which technologies are reliable?

Authors:  Martin Petzoldt; Daniel A Reuter
Journal:  J Clin Monit Comput       Date:  2015-03-26       Impact factor: 2.502

3.  Reliability of transcardiopulmonary thermodilution cardiac output measurement in experimental aortic valve insufficiency.

Authors:  Martin Petzoldt; Constantin J Trepte; Jan Ridder; Stefan Maisch; Philipp Klapsing; Jan F Kersten; Hans Peter Richter; Jens C Kubitz; Daniel A Reuter; Matthias S Goepfert
Journal:  PLoS One       Date:  2017-10-19       Impact factor: 3.240

  3 in total