Literature DB >> 17848679

Lower extremity arterial disease: multidetector CT angiography meta-analysis.

Majanka H Heijenbrok-Kal1, Marc C J M Kock, M G Myriam Hunink.   

Abstract

PURPOSE: To obtain the best available estimates of the diagnostic performance of multidetector computed tomographic (CT) angiography compared with that of digital subtraction angiography (DSA) in the assessment of symptomatic lower extremity arterial disease and to identify the most important sources of variation in diagnostic performance between studies.
MATERIALS AND METHODS: Reports of studies published from January 2000 through April 2006 in English, German, French, or Spanish were searched for by using the MEDLINE, EMBASE, and Cochrane databases. Studies were included if they allowed construction of 2 x 2 contingency tables for the detection of stenosis of 50% or greater at multidetector CT angiography compared with that at DSA -- the reference standard -- in patients with claudication or critical ischemia. Two observers extracted data about study design, patient characteristics, arterial tracts, and technical protocols. Random-effects summary receiver operating characteristic analysis was performed to examine the influence of these data on diagnostic performance.
RESULTS: Of the 70 studies initially identified, 12 were included in which multidetector CT angiography was used to evaluate 9541 arterial segments in 436 patients. The pooled sensitivity and specificity for detecting a stenosis of at least 50% per segment were 92% (95% confidence interval: 89%, 95%) and 93% (95% confidence interval: 91%, 95%), respectively. Three studies provided data about the diagnostic performance of multidetector CT angiography in subdivisions of the arterial tract. The diagnostic performance of multidetector CT angiography in the infrapopliteal tract was lower than but not significantly different from that in the aortoiliac (P > .11) and femoropopliteal (P > .40) tracts. Regression analysis showed that diagnostic performance was not significantly influenced by differences in study characteristics.
CONCLUSION: Multidetector CT angiography is an accurate diagnostic test in the assessment of arterial disease (> or =50% stenosis) of the entire lower extremity.

Entities:  

Mesh:

Year:  2007        PMID: 17848679     DOI: 10.1148/radiol.2451061280

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  21 in total

1.  Diagnostic value of time-resolved CT angiography for the lower leg.

Authors:  Wieland H Sommer; Andreas Helck; Fabian Bamberg; Edda Albrecht; Christoph R Becker; Rolf Weidenhagen; Harald Kramer; Maximilian F Reiser; Konstantin Nikolaou
Journal:  Eur Radiol       Date:  2010-06-30       Impact factor: 5.315

Review 2.  Current state of diagnosis and management of critical limb ischemia.

Authors:  Dan Clair; Samir Shah; John Weber
Journal:  Curr Cardiol Rep       Date:  2012-04       Impact factor: 2.931

Review 3.  Hybrid interventions in limb salvage.

Authors:  Tam T T Huynh; Carlos F Bechara
Journal:  Methodist Debakey Cardiovasc J       Date:  2013-04

4.  Assessment of vascular invasion by bone and soft tissue tumours of the limbs: usefulness of MDCT angiography.

Authors:  Fabrice S Thévenin; Jean-Luc Drapé; David Biau; Raphaël Campagna; Delphine Richarme; Henri Guerini; Alain Chevrot; Frédérique Larousserie; Antoine Babinet; Philippe Anract; Antoine Feydy
Journal:  Eur Radiol       Date:  2009-12-17       Impact factor: 5.315

5.  Dual-energy CT angiography in peripheral arterial occlusive disease-accuracy of maximum intensity projections in clinical routine and subgroup analysis.

Authors:  Thomas Kau; Wolfgang Eicher; Christian Reiterer; Martin Niedermayer; Egon Rabitsch; Birgit Senft; Klaus A Hausegger
Journal:  Eur Radiol       Date:  2011-03-02       Impact factor: 5.315

6.  Modified calcium subtraction in dual-energy CT angiography of the lower extremity runoff: impact on diagnostic accuracy for stenosis detection.

Authors:  Domenico De Santis; Carlo N De Cecco; U Joseph Schoepf; John W Nance; Ricardo T Yamada; Brooke A Thomas; Katharina Otani; Brian E Jacobs; D Alan Turner; Julian L Wichmann; Marwen Eid; Akos Varga-Szemes; Damiano Caruso; Katharine L Grant; Bernhard Schmidt; Thomas J Vogl; Andrea Laghi; Moritz H Albrecht
Journal:  Eur Radiol       Date:  2019-02-25       Impact factor: 5.315

Review 7.  Diagnostics and treatment of the diabetic foot.

Authors:  Jan Apelqvist
Journal:  Endocrine       Date:  2012-02-25       Impact factor: 3.633

8.  Atherosclerosis in sickle cell disease - a review.

Authors:  Mohamed A Elsharawy; Khaled M Moghazy; Mohamed A Shawarby
Journal:  Int J Angiol       Date:  2009

9.  Segmental Comparison of Peripheral Arteries by Doppler Ultrasound and CT Angiography.

Authors:  Prem Kumar Chidambaram; Ram Kumar Swaminathan; Prakash Ganesan; Manibharathi Mayavan
Journal:  J Clin Diagn Res       Date:  2016-02-01

10.  A noise-optimized virtual monochromatic reconstruction algorithm improves stent visualization and diagnostic accuracy for detection of in-stent re-stenosis in lower extremity run-off CT angiography.

Authors:  Stefanie Mangold; Carlo N De Cecco; U Joseph Schoepf; Ricardo T Yamada; Akos Varga-Szemes; Andrew C Stubenrauch; Damiano Caruso; Stephen R Fuller; Thomas J Vogl; Konstantin Nikolaou; Thomas M Todoran; Julian L Wichmann
Journal:  Eur Radiol       Date:  2016-03-09       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.