Similar to other tomographic imaging modalities, the slice sensitivity profile (SSP) is an important image quality metric for radiographic tomosynthesis. In this study, the relationship between the acquisition angular range (Theta) and the SSP for the linear trajectory system was carefully investigated from both theoretical and experimental perspectives. A mathematical SSP model was derived for arbitrary points in the reconstructed volume. We used a newly developed flat-panel tomosynthesis prototype system to experimentally validate the mathematical model from 20 degrees (+/-10 degrees) to 60 degrees (+/-30 degrees) angular ranges. The SSP was measured by imaging an edge phantom placed at an angle with respect to the detector plane using the modulation transfer function degradation (MTF-d) method. In addition to the experiments, computer simulations were performed to investigate the relationship in a wider angular range (2.5 degrees to 60 degrees). Furthermore, image data from an anthropomorphic phantom were collected to corroborate the system analysis. All the images in this study were constructed using a 3D view-weighted cone-beam filtered backprojection algorithm (3D VW CB-FBP). The theoretical analysis reveals that the SSP of linear trajectory tomosynthesis is inversely proportional to tan(Theta/2). This theory was supported by both simulation (chi2=1.415, DF=7, p =0.985) and phantom experiment (r=0.999, p < 0.001) and was further confirmed by an analysis of the reconstructed images of an anthropomorphic phantom. The results imply that the benefit of narrower SSP by increasing angular range quickly diminishes once beyond 40 degrees. The advantages of the MTF-d method were also demonstrated.

Entities:  

Mesh:

Year:  2007        PMID: 17821999     DOI: 10.1118/1.2742499

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  Image quality of microcalcifications in digital breast tomosynthesis: effects of projection-view distributions.

Authors:  Yao Lu; Heang-Ping Chan; Jun Wei; Mitch Goodsitt; Paul L Carson; Lubomir Hadjiiski; Andrea Schmitz; Jeffrey W Eberhard; Bernhard E H Claus
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  Analysis of the impact of digital tomosynthesis on the radiological investigation of patients with suspected pulmonary lesions on chest radiography.

Authors:  Emilio Quaia; Elisa Baratella; Stefano Cernic; Arianna Lorusso; Federica Casagrande; Vincenzo Cioffi; Maria Assunta Cova
Journal:  Eur Radiol       Date:  2012-04-27       Impact factor: 5.315

3.  Experimental validation of a three-dimensional linear system model for breast tomosynthesis.

Authors:  Bo Zhao; Jun Zhou; Yue-Houng Hu; Thomas Mertelmeier; Jasmina Ludwig; Wei Zhao
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

4.  Image artifacts in digital breast tomosynthesis: investigation of the effects of system geometry and reconstruction parameters using a linear system approach.

Authors:  Yue-Houng Hu; Bo Zhao; Wei Zhao
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

5.  Three-dimensional linear system analysis for breast tomosynthesis.

Authors:  Bo Zhao; Wei Zhao
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

Review 6.  Tomosynthesis imaging: at a translational crossroads.

Authors:  James T Dobbins
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

7.  Comprehensive assessment of the slice sensitivity profiles in breast tomosynthesis and breast CT.

Authors:  Anita Nosratieh; Kai Yang; Shadi Aminololama-Shakeri; John M Boone
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

8.  Evaluation of respiration-correlated digital tomosynthesis in lung.

Authors:  Joseph Santoro; Sergey Kriminski; D Michael Lovelock; Kenneth Rosenzweig; Hassan Mostafavi; Howard I Amols; Gig S Mageras
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

9.  Diagnostic impact of digital tomosynthesis in oncologic patients with suspected pulmonary lesions on chest radiography.

Authors:  Emilio Quaia; Elisa Baratella; Gabriele Poillucci; Antonio Giulio Gennari; Maria Assunta Cova
Journal:  Eur Radiol       Date:  2015-12-01       Impact factor: 5.315

10.  Real-time out-of-plane artifact subtraction tomosynthesis imaging using prior CT for scanning beam digital x-ray system.

Authors:  Meng Wu; Rebecca Fahrig
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.