A 50 MHz ultrasound backscatter microscope has been built to measure the acoustic properties of vascular tissues and blood over the frequency range from 35-65 MHz. High resolution (45 microns) ultrasound backscatter microscope images of nine femoral and eight common carotid human artery samples were made and compared with corresponding histological sections. Individual tissue layers were selected using these images for quantitative measurement of the frequency dependent backscatter. Backscatter measurements were made in each layer of an artery at two different angles of incidence: along the axis of the artery (axial direction) and at 90 degrees to this measurement radially out from the center of the artery (radial direction). Scattering was found to be higher in elastic arteries (carotid) than in the muscular arteries (femoral). The largest difference was found in the media where the average scatter (measured in the radial direction at 50 MHz) increased from 0.002 sr-1 mm-1 in muscular arteries to 0.4 sr-1 mm-1 in elastic arteries. Large differences in scattering between measurements made in the axial and radial direction were also found. Again, the largest differences were found in the media where scattering (at 50 MHz) in carotid arteries increased from 0.003 sr-1 mm-1 measured in the axial direction to 0.4 sr-1 mm-1 measured in the radial direction. The speed of sound and attenuation in the artery wall of each sample were measured. Speed of sound measurements were found to range between 1579-1628 ms-1. The average attenuation in the artery wall increased from 4 dB mm-1 at 30 MHz to 10 dB mm-1 at 60 mHz. This is higher than the attenuation measured in blood which increased from 1.6 dB mm-1 to 5 dB mm-1 over the same frequency range. The backscatter coefficient for flowing blood was measured for flow velocities up to 36 cms-1. At flow velocities below 18 cms-1 a level of scattering of 0.0005 sr-1 mm-1 (at 50 MHz) was found. An increase in scattering of 1.6 times was measured when the flow velocity was increased to 36 cms-1. All measurements were made at 37 degrees C. The relevance of these results to clinical imaging and image interpretation is discussed.

Entities:  

Mesh:

Year:  1991        PMID: 1781068     DOI: 10.1016/0301-5629(91)90096-f

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  14 in total

1.  Time domain attenuation estimation method from ultrasonic backscattered signals.

Authors:  Goutam Ghoshal; Michael L Oelze
Journal:  J Acoust Soc Am       Date:  2012-07       Impact factor: 1.840

2.  Ultrasonic characterization of porcine liver tissue at frequency between 25 to 55 MHz.

Authors:  Xiao-Zhou Liu; Xiu-Fen Gong; Dong Zhang; Shi-Gong Ye; Bing Rui
Journal:  World J Gastroenterol       Date:  2006-04-14       Impact factor: 5.742

3.  Multilayered tissue mimicking skin and vessel phantoms with tunable mechanical, optical, and acoustic properties.

Authors:  Alvin I Chen; Max L Balter; Melanie I Chen; Daniel Gross; Sheikh K Alam; Timothy J Maguire; Martin L Yarmush
Journal:  Med Phys       Date:  2016-06       Impact factor: 4.071

4.  Characterization of the spatial resolution of different high-frequency imaging systems using a novel anechoic-sphere phantom.

Authors:  Erwan Filoux; Jonathan Mamou; Orlando Aristizábal; Jeffrey A Ketterling
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-05       Impact factor: 2.725

5.  Layer-dependent variation in the anisotropy of apparent integrated backscatter from human coronary arteries.

Authors:  Joseph J Hoffman; Benjamin L Johnson; Mark R Holland; Russell J Fedewa; Anuja Nair; James G Miller
Journal:  Ultrasound Med Biol       Date:  2011-03-03       Impact factor: 2.998

6.  Anechoic sphere phantoms for estimating 3-D resolution of very-high-frequency ultrasound scanners.

Authors:  Ernest Madsen; Gary Frank; Matthew McCormick; Meagan Deaner; Timothy Stiles
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-10       Impact factor: 2.725

7.  Neonatal cardiomyopathy in mice homozygous for the Arg403Gln mutation in the alpha cardiac myosin heavy chain gene.

Authors:  D Fatkin; M E Christe; O Aristizabal; B K McConnell; S Srinivasan; F J Schoen; C E Seidman; D H Turnbull; J G Seidman
Journal:  J Clin Invest       Date:  1999-01       Impact factor: 14.808

8.  Relationship between ultrasonic attenuation, size and axial strain parameters for ex vivo atherosclerotic carotid plaque.

Authors:  Hairong Shi; Tomy Varghese; Robert J Dempsey; Mohammed S Salamat; James A Zagzebski
Journal:  Ultrasound Med Biol       Date:  2008-05-19       Impact factor: 2.998

9.  Characterisation of coronary atherosclerotic morphology by spectral analysis of radiofrequency signal: in vitro intravascular ultrasound study with histological and radiological validation.

Authors:  M P Moore; T Spencer; D M Salter; P P Kearney; T R Shaw; I R Starkey; P J Fitzgerald; R Erbel; A Lange; N W McDicken; G R Sutherland; K A Fox
Journal:  Heart       Date:  1998-05       Impact factor: 5.994

10.  Ex Vivo Porcine Arterial and Chorioallantoic Membrane Acoustic Angiography Using Dual-Frequency Intravascular Ultrasound Probes.

Authors:  K Heath Martin; Brooks D Lindsey; Jianguo Ma; Timothy C Nichols; Xiaoning Jiang; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2016-05-31       Impact factor: 2.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.