Literature DB >> 20889416

Anechoic sphere phantoms for estimating 3-D resolution of very-high-frequency ultrasound scanners.

Ernest Madsen1, Gary Frank, Matthew McCormick, Meagan Deaner, Timothy Stiles.   

Abstract

Two phantoms have been constructed for assessing performance of high-frequency ultrasound imagers. They also allow for periodic quality assurance tests and training technicians in the use of higher-frequency scanners. The phantoms contain eight blocks of tissue-mimicking material; each block contains a spatially random distribution of suitably small anechoic spheres having a small distribution of diameters. The eight mean sphere diameters are distributed from 0.10 to 1.09 mm. The two phantoms differ primarily in terms of the frequency dependence of the backscatter coefficient of the background material. Because spheres have no preferred orientation, all three (spatial) dimensions of resolution contribute to sphere detection on an equal basis; thus, the resolution is termed 3-D. Two high-frequency scanners are compared. One employs single-element (fixed focus) transducers (25 and 55 MHz), and the other employs variable focus linear arrays (20, 30, and 40 MHz). The depth range for detection of spheres of each size is determined corresponding to determination of 3-D resolution as a function of depth. As expected, the single-element transducers are severely limited in useful imaging depth ranges compared with the linear arrays. In this preliminary report, only one human observer analyzed images.

Entities:  

Mesh:

Year:  2010        PMID: 20889416      PMCID: PMC3769966          DOI: 10.1109/TUFFC.2010.1689

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  5 in total

1.  Interlaboratory comparison of ultrasonic backscatter, attenuation, and speed measurements.

Authors:  E L Madsen; F Dong; G R Frank; B S Garra; K A Wear; T Wilson; J A Zagzebski; H L Miller; K K Shung; S H Wang; E J Feleppa; T Liu; W D O'Brien; K A Topp; N T Sanghvi; A V Zaitsev; T J Hall; J B Fowlkes; O D Kripfgans; J G Miller
Journal:  J Ultrasound Med       Date:  1999-09       Impact factor: 2.153

2.  Improved method for determining resolution zones in ultrasound phantoms with spherical simulated lesions.

Authors:  J M Kofler; E L Madsen
Journal:  Ultrasound Med Biol       Date:  2001-12       Impact factor: 2.998

3.  Interlaboratory comparison of ultrasonic backscatter coefficient measurements from 2 to 9 MHz.

Authors:  Keith A Wear; Timothy A Stiles; Gary R Frank; Ernest L Madsen; Francis Cheng; Ernest J Feleppa; Christopher S Hall; Beom Soo Kim; Paul Lee; William D O'Brien; Michael L Oelze; Balasundar I Raju; K Kirk Shung; Thaddeus A Wilson; Jian R Yuan
Journal:  J Ultrasound Med       Date:  2005-09       Impact factor: 2.153

4.  Measurement of the ultrasonic properties of vascular tissues and blood from 35-65 MHz.

Authors:  G R Lockwood; L K Ryan; J W Hunt; F S Foster
Journal:  Ultrasound Med Biol       Date:  1991       Impact factor: 2.998

5.  Liquid or solid ultrasonically tissue-mimicking materials with very low scatter.

Authors:  E L Madsen; G R Frank; F Dong
Journal:  Ultrasound Med Biol       Date:  1998-05       Impact factor: 2.998

  5 in total
  17 in total

1.  Absolute backscatter coefficient estimates of tissue-mimicking phantoms in the 5-50 MHz frequency range.

Authors:  Matthew M McCormick; Ernest L Madsen; Meagan E Deaner; Tomy Varghese
Journal:  J Acoust Soc Am       Date:  2011-08       Impact factor: 1.840

2.  A sidelobe suppressing near-field beamforming approach for ultrasound array imaging.

Authors:  Zhengyao He; Fan Zheng; Yuanliang Ma; Hyung Ham Kim; Qifa Zhou; K Kirk Shung
Journal:  J Acoust Soc Am       Date:  2015-05       Impact factor: 1.840

3.  Properties of phantom tissuelike polymethylpentene in the frequency range 20-70 MHZ.

Authors:  Ernest L Madsen; Meagan E Deaner; James Mehi
Journal:  Ultrasound Med Biol       Date:  2011-08       Impact factor: 2.998

4.  A high-frequency linear ultrasonic array utilizing an interdigitally bonded 2-2 piezo-composite.

Authors:  Jonathan M Cannata; Jay A Williams; Lequan Zhang; Chang-Hong Hu; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-10       Impact factor: 2.725

5.  An open system for intravascular ultrasound imaging.

Authors:  Weibao Qiu; Yan Chen; Xiang Li; Yanyan Yu; Wang Fai Cheng; Fu Keung Tsang; Qifa Zhou; K Kirk Shung; Jiyan Dai; Lei Sun
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-10       Impact factor: 2.725

6.  Ultrasound bio-microscopic image segmentation for evaluation of zebrafish cardiac function.

Authors:  Xiaowei Zhou; Lei Sun; Yanyan Yu; Weibao Qiu; Ching-Ling Lien; K Kirk Shung; Weichuan Yu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-04       Impact factor: 2.725

7.  Pulse inversion chirp coded tissue harmonic imaging (PI-CTHI) of Zebrafish heart using high frame rate ultrasound biomicroscopy.

Authors:  Jinhyoung Park; Ying Huang; Ruimin Chen; Jungwoo Lee; Thomas M Cummins; Qifa Zhou; Ching-Ling Lien; K K Shung
Journal:  Ann Biomed Eng       Date:  2012-08-29       Impact factor: 3.934

8.  Stand-alone front-end system for high- frequency, high-frame-rate coded excitation ultrasonic imaging.

Authors:  Jinhyoung Park; Changhong Hu; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-12       Impact factor: 2.725

9.  A flexible annular-array imaging platform for micro-ultrasound.

Authors:  Weibao Qiu; Yanyan Yu; Hamid Reza Chabok; Cheng Liu; Fu Keung Tsang; Qifa Zhou; K Kirk Shung; Hairong Zheng; Lei Sun
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-01       Impact factor: 2.725

10.  Non-planar pad-printed thick-film focused high-frequency ultrasonic transducers for imaging and therapeutic applications.

Authors:  Marc Lethiecq; Rasmus Lou-Moeller; Jeffrey Ketterling; Franck Levassort; Louis Pascal Tran-Huu-Hue; Erwan Filoux; Ronald H Silverman; Wanda W Wolny
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-09       Impact factor: 2.725

View more