Literature DB >> 17717664

Computer-assisted placement technique in hip resurfacing arthroplasty: improvement in accuracy?

S Krüger1, P Y Zambelli, P-F Leyvraz, B M Jolles.   

Abstract

Freehand positioning of the femoral drill guide is difficult during hip resurfacing and the surgeon is often unsure of the implant position achieved peroperatively. The purpose of this study was to find out whether, by using a navigation system, acetabular and femoral component positioning could be made easier and more precise. Eighteen patients operated on by the same surgeon were matched by sex, age, BMI, diagnosis and ASA score (nine patients with computer assistance, nine with the regular ancillary). Pre-operative planning was done on standard AP and axial radiographs with CT scan views for the computer-assisted operations. The final position of implants was evaluated by the same radiographs for all patients. The follow-up was at least 1 year. No difference between both groups in terms of femoral component position was observed (p > 0.05). There was also no difference in femoral notching. A trend for a better cup position was observed for the navigated hips, especially for cup anteversion. There was no additional operating time for the navigated hips. Hip navigation for resurfacing surgery may allow improved visualisation and hip implant positioning, but its advantage probably will be more obvious with mini-incisions than with regular incision surgery.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17717664      PMCID: PMC2899204          DOI: 10.1007/s00264-007-0440-8

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  22 in total

1.  Optimal femoral head contour segmentation in CT images using dynamic programming.

Authors:  Gaëtan Marti; Charles Baur; Pierre-Yves Zambelli
Journal:  Technol Health Care       Date:  2004       Impact factor: 1.285

2.  Hip resurfacing arthroplasty.

Authors:  Harlan C Amstutz
Journal:  J Am Acad Orthop Surg       Date:  2006-08       Impact factor: 3.020

3.  Radiological demarcation of cemented sockets in total hip replacement.

Authors:  J G DeLee; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1976 Nov-Dec       Impact factor: 4.176

4.  Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation.

Authors:  W H Harris
Journal:  J Bone Joint Surg Am       Date:  1969-06       Impact factor: 5.284

5.  Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee.

Authors:  N Bellamy; W W Buchanan; C H Goldsmith; J Campbell; L W Stitt
Journal:  J Rheumatol       Date:  1988-12       Impact factor: 4.666

6.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

7.  Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis.

Authors:  B M Jolles; P Zangger; P-F Leyvraz
Journal:  J Arthroplasty       Date:  2002-04       Impact factor: 4.757

8.  Computer-assisted cup placement techniques in total hip arthroplasty improve accuracy of placement.

Authors:  Brigitte M Jolles; Patrick Genoud; Pierre Hoffmeyer
Journal:  Clin Orthop Relat Res       Date:  2004-09       Impact factor: 4.176

9.  Metal-on-metal hybrid surface arthroplasty: two to six-year follow-up study.

Authors:  Harlan C Amstutz; Paul E Beaulé; Frederick J Dorey; Michel J Le Duff; Pat A Campbell; Thomas A Gruen
Journal:  J Bone Joint Surg Am       Date:  2004-01       Impact factor: 5.284

10.  Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis.

Authors:  J Daniel; P B Pynsent; D J W McMinn
Journal:  J Bone Joint Surg Br       Date:  2004-03
View more
  17 in total

1.  Intra- and extra-articular planes of reference for use in total hip arthroplasty: a preliminary study.

Authors:  Jerome Hausselle; Pierre Etienne Moreau; Loic Wessely; Emmanuel de Thomasson; Ayman Assi; Sebastien Parratte; Jerome Essig; Wafa Skalli
Journal:  Int Orthop       Date:  2012-03-21       Impact factor: 3.075

2.  Bone mineral density in the femoral neck increases after hip resurfacing: a cohort with five-year follow-up.

Authors:  Charles A Willis-Owen; Henry D Atkinson; Roger D Oakeshott
Journal:  Int Orthop       Date:  2010-08-22       Impact factor: 3.075

3.  Intraoperative radiographs for placing acetabular components in hip resurfacing arthroplasty.

Authors:  Thomas P Gross; Fei Liu; Lee Webb
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

4.  Indications and results of hip resurfacing.

Authors:  D J W McMinn; J Daniel; H Ziaee; C Pradhan
Journal:  Int Orthop       Date:  2010-11-16       Impact factor: 3.075

5.  Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy.

Authors:  C Schnurr; J W P Michael; P Eysel; D P König
Journal:  Int Orthop       Date:  2007-12-22       Impact factor: 3.075

6.  A simple technique for alignment in total hip resurfacing arthroplasty: technical note and preliminary report.

Authors:  Manuel Villanueva-Martínez; Antonio Ríos-Luna; Angel Villamor-Pérez
Journal:  HSS J       Date:  2009-06-09

7.  The Birmingham Hip Resurfacing: 5-year clinical and radiographic results from a District General Hospital.

Authors:  B Ollivere; S Duckett; A August; M Porteous
Journal:  Int Orthop       Date:  2009-06-09       Impact factor: 3.075

8.  Component alignment in hip resurfacing using computer navigation.

Authors:  Chris Bailey; Rehan Gul; Mark Falworth; Steven Zadow; Roger Oakeshott
Journal:  Clin Orthop Relat Res       Date:  2008-10-30       Impact factor: 4.176

9.  [Best matching. Experimental comparison of different matching procedures for use in computer navigation].

Authors:  A Schäffler; B König; N P Haas; U Stöckle
Journal:  Unfallchirurg       Date:  2009-09       Impact factor: 1.000

10.  The First SICOT Oral Presentation Award 2011: imageless computer-assisted femoral component positioning in hip resurfacing: a prospective randomised trial.

Authors:  Maik Stiehler; Jens Goronzy; Albrecht Hartmann; Frank Krummenauer; Klaus-Peter Günther
Journal:  Int Orthop       Date:  2013-02-06       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.