Literature DB >> 19319514

Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease.

Moez Ben Saad1, Adela Rohnean, Anne Sigal-Cinqualbre, Ghazal Adler, Jean-Francois Paul.   

Abstract

BACKGROUND: There are only a few reports on the diagnostic accuracy, and the technical and clinical feasibility, of multidetector CT (MDCT) in infants with congenital heart disease (CHD).
OBJECTIVE: To evaluate the image quality and radiation dose of DSCT in babies with CHD.
MATERIALS AND METHODS: From November 2006 to November 2007, 110 consecutive infants with CHD referred for pre- or postoperative CT evaluation were included. All these infants had a spiral angiothoracic DSCT scan after injection of 300 mg/ml iopromide at 0.5-1 ml/s with a power injector using a low-dose protocol (80 kVp and 10 mAs/kg). Of these infants, 34 also underwent an ECG-gated coronary CT scan for evaluation of the course of the coronary arteries.
RESULTS: No serious adverse events were recorded. The mean dose-length product was 8+/-6 mGy x cm (effective dose 0.5+/-0.2 mSv) and 21+/-9 mGy x cm (effective dose 1.3+/-0.6 mSv) during the non-ECG-gated spiral acquisition and ECG-gated acquisition, respectively. Diagnostic quality images were achieved with the spiral acquisition in 89% of cases. Compared to the spiral mode, ECG-gated acquisition significantly improved the visualization of the coronary arteries, with a diagnostic rate of 91% and 84% for the left and right coronary arteries, respectively.
CONCLUSION: DSCT together with iopromide at 300 mg/ml is a valuable tool for the routine clinical evaluation of infants with CHD. ECG-gated acquisition provides reliable visualization of the course of the coronary arteries.

Entities:  

Mesh:

Year:  2009        PMID: 19319514     DOI: 10.1007/s00247-009-1209-6

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  24 in total

1.  Dual-source CT cardiac imaging: initial experience.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Bernd J Wintersperger; Alexander W Leber; Franz von Ziegler; Carsten Rist; Sonja Buhmann; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-05-13       Impact factor: 5.315

Review 2.  Dual source CT: cardio-pulmonary applications.

Authors:  X Hamoir; D Salovic; T Bouziane; J Kirsch
Journal:  JBR-BTR       Date:  2007 Mar-Apr

3.  Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability.

Authors:  David Matt; Hans Scheffel; Sebastian Leschka; Thomas G Flohr; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  AJR Am J Roentgenol       Date:  2007-09       Impact factor: 3.959

4.  Visualization of coronary arteries in patients after childhood Kawasaki syndrome: value of multidetector CT and MR imaging in comparison to conventional coronary catheterization.

Authors:  Raoul Arnold; Sebastian Ley; Julia Ley-Zaporozhan; Joachim Eichhorn; Jens-Peter Schenk; Herbert Ulmer; Hans-Ulrich Kauczor
Journal:  Pediatr Radiol       Date:  2007-09-01

5.  Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method.

Authors:  Karen E Thomas; Bo Wang
Journal:  Pediatr Radiol       Date:  2008-04-08

6.  Patient radiation doses from adult and pediatric CT.

Authors:  Walter Huda; Awais Vance
Journal:  AJR Am J Roentgenol       Date:  2007-02       Impact factor: 3.959

7.  Tube current reduction in pediatric non-ECG-gated heart CT by combined tube current modulation.

Authors:  Hyun Woo Goo; Hyum Woo Goo; Dong Soo Suh
Journal:  Pediatr Radiol       Date:  2006-02-25

8.  Using multidetector-row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: initial experiences in technical and clinical feasibility.

Authors:  Tain Lee; I-Chen Tsai; Yun-Ching Fu; Sheng-Lin Jan; Chung-Chi Wang; Yen Chang; Min-Chi Chen
Journal:  Pediatr Radiol       Date:  2006-10-12

9.  Accurate quantification of pulmonary artery diameter in patients with cyanotic congenital heart disease using multidetector-row computed tomography.

Authors:  Yasunobu Hayabuchi; Kazuhiro Mori; Tetsuya Kitagawa; Miki Inoue; Shoji Kagami
Journal:  Am Heart J       Date:  2007-10       Impact factor: 4.749

10.  Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT--a pooled analysis of two randomized trials.

Authors:  Henrik S Thomsen; Sameh K Morcos
Journal:  Eur Radiol       Date:  2008-11-11       Impact factor: 5.315

View more
  46 in total

1.  Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience.

Authors:  Zhaoping Cheng; Ximing Wang; Yanhua Duan; Lebin Wu; Dawei Wu; Baoting Chao; Cheng Liu; Zhuodong Xu; Hongxin Li; Fei Liang; Jian Xu; Jiuhong Chen
Journal:  Eur Radiol       Date:  2010-06-09       Impact factor: 5.315

2.  Clinical indications for cardiac computed tomography. From the Working Group of the Cardiac Radiology Section of the Italian Society of Medical Radiology (SIRM).

Authors:  E di Cesare; I Carbone; A Carriero; M Centonze; F De Cobelli; R De Rosa; P Di Renzi; A Esposito; R Faletti; R Fattori; M Francone; A Giovagnoni; L La Grutta; G Ligabue; L Lovato; R Marano; M Midiri; L Natale; A Romagnoli; V Russo; F Sardanelli; F Cademartiri
Journal:  Radiol Med       Date:  2012-04-01       Impact factor: 3.469

3.  Coronary artery visibility in free-breathing young children with congenital heart disease on cardiac 64-slice CT: dual-source ECG-triggered sequential scan vs. single-source non-ECG-synchronized spiral scan.

Authors:  Hyun Woo Goo; Dong Hyun Yang
Journal:  Pediatr Radiol       Date:  2010-05-13

4.  Assessments of Coronary Artery Visibility and Radiation Dose in Infants with Congenital Heart Disease on Cardiac 128-slice CT and on Cardiac 64-slice CT.

Authors:  Y Cui; M Huang; J Zheng; J Li; H Liu; C Liang
Journal:  Pediatr Cardiol       Date:  2015-08-14       Impact factor: 1.655

5.  Accuracy, image quality and radiation dose comparison of high-pitch spiral and sequential acquisition on 128-slice dual-source CT angiography in children with congenital heart disease.

Authors:  Pei Nie; Ximing Wang; Zhaoping Cheng; Xiaopeng Ji; Yanhua Duan; Jiuhong Chen
Journal:  Eur Radiol       Date:  2012-05-18       Impact factor: 5.315

Review 6.  Paediatric cardiac computed tomography: a review of imaging techniques and radiation dose consideration.

Authors:  Carolyn Young; Andrew M Taylor; Catherine M Owens
Journal:  Eur Radiol       Date:  2010-12-28       Impact factor: 5.315

7.  Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart diseases: comparison of image quality and radiation dose.

Authors:  Kwang Nam Jin; Eun-Ah Park; Cheong-Il Shin; Whal Lee; Jin Wook Chung; Jae Hyung Park
Journal:  Int J Cardiovasc Imaging       Date:  2010-01-01       Impact factor: 2.357

8.  Critical stenosis of a right ventricle to coronary artery fistula seen at dual-source CT in a newborn with pulmonary atresia and intact ventricular septum.

Authors:  Pierre-Emmanuel Séguéla; Lucile Houyel; Philippe Loget; Jean-Dominique Piot; Jean-François Paul
Journal:  Pediatr Radiol       Date:  2011-04-13

9.  Quantitative evaluation of coronary artery visibility on CT angiography in Kawasaki disease: young vs. old children.

Authors:  Hyun Woo Goo
Journal:  Int J Cardiovasc Imaging       Date:  2020-10-12       Impact factor: 2.357

10.  Scan time and patient dose for thoracic imaging in neonates and small children using axial volumetric 320-detector row CT compared to helical 64-, 32-, and 16- detector row CT acquisitions.

Authors:  Lucia J M Kroft; Joost J H Roelofs; Jacob Geleijns
Journal:  Pediatr Radiol       Date:  2009-12-08
View more