Image reconstruction and image quality evaluation for a dual source CT scanner.

T G Flohr1, H Bruder, K Stierstorfer, M Petersilka, B Schmidt, C H McCollough.   

Abstract

The authors present and evaluate concepts for image reconstruction in dual source CT (DSCT). They describe both standard spiral (helical) DSCT image reconstruction and electrocardiogram (ECG)-synchronized image reconstruction. For a compact mechanical design of the DSCT, one detector (A) can cover the full scan field of view, while the other detector (B) has to be restricted to a smaller, central field of view. The authors develop an algorithm for scan data completion, extrapolating truncated data of detector (B) by using data of detector (A). They propose a unified framework for convolution and simultaneous 3D backprojection of both (A) and (B) data, with similar treatment of standard spiral, ECG-gated spiral, and sequential (axial) scan data. In ECG-synchronized image reconstruction, a flexible scan data range per measurement system can be used to trade off temporal resolution for reduced image noise. Both data extrapolation and image reconstruction are evaluated by means of computer simulated data of anthropomorphic phantoms, by phantom measurements and patient studies. The authors show that a consistent filter direction along the spiral tangent on both detectors is essential to reduce cone-beam artifacts, requiring truncation of the extrapolated (B) data after convolution in standard spiral scans. Reconstructions of an anthropomorphic thorax phantom demonstrate good image quality and dose accumulation as theoretically expected for simultaneous 3D backprojection of the filtered (A) data and the truncated filtered (B) data into the same 3D image volume. In ECG-gated spiral modes, spiral slice sensitivity profiles (SSPs) show only minor dependence on the patient's heart rate if the spiral pitch is properly adapted. Measurements with a thin gold plate phantom result in effective slice widths (full width at half maximum of the SSP) of 0.63-0.69 mm for the nominal 0.6 mm slice and 0.82-0.87 mm for the nominal 0.75 mm slice. The visually determined through-plane (z axis) spatial resolution in a bar pattern phantom is 0.33-0.36 mm for the nominal 0.6 mm slice and 0.45 mm for the nominal 0.75 mm slice, again almost independent of the patient's heart rate. The authors verify the theoretically expected temporal resolution of 83 ms at 330 ms gantry rotation time by blur free images of a moving coronary artery phantom with 90 ms rest phase and demonstrate image noise reduction as predicted for increased reconstruction data ranges per measurement system. Finally, they show that the smoothness of the transition between image stacks acquired in different cardiac cycles can be efficiently controlled with the proposed approach for ECG-synchronized image reconstruction.

Entities:  

Mesh:

Year:  2008        PMID: 19175144      PMCID: PMC4109745          DOI: 10.1118/1.3020756

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  31 in total

1.  Subsecond multi-slice computed tomography: basics and applications.

Authors:  K Klingenbeck-Regn; S Schaller; T Flohr; B Ohnesorge; A F Kopp; U Baum
Journal:  Eur J Radiol       Date:  1999-08       Impact factor: 3.528

2.  Four multidetector-row helical CT: image quality and volume coverage speed.

Authors:  H Hu; H D He; W D Foley; S H Fox
Journal:  Radiology       Date:  2000-04       Impact factor: 11.105

3.  Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience.

Authors:  B Ohnesorge; T Flohr; C Becker; A F Kopp; U J Schoepf; U Baum; A Knez; K Klingenbeck-Regn; M F Reiser
Journal:  Radiology       Date:  2000-11       Impact factor: 11.105

4.  In-plane coronary arterial motion velocity: measurement with electron-beam CT.

Authors:  S Achenbach; D Ropers; J Holle; G Muschiol; W G Daniel; W Moshage
Journal:  Radiology       Date:  2000-08       Impact factor: 11.105

5.  ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart.

Authors:  M Kachelriess; S Ulzheimer; W A Kalender
Journal:  Med Phys       Date:  2000-08       Impact factor: 4.071

6.  Do segmented reconstruction algorithms for cardiac multi-slice computed tomography improve image quality?

Authors:  Sandra S Halliburton; Arthur E Stillman; Thomas Flohr; Bernd Ohnesorge; Nancy Obuchowski; Michael Lieber; Wadih Karim; Stacie A Kuzmiak; Jane M Kasper; Richard D White
Journal:  Herz       Date:  2003-02       Impact factor: 1.443

7.  Image reconstruction and image quality evaluation for a 16-slice CT scanner.

Authors:  Th Flohr; K Stierstorfer; H Bruder; J Simon; A Polacin; S Schaller
Journal:  Med Phys       Date:  2003-05       Impact factor: 4.071

8.  Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart.

Authors:  T Flohr; B Ohnesorge
Journal:  J Comput Assist Tomogr       Date:  2001 Nov-Dec       Impact factor: 1.826

9.  Image reconstruction and performance evaluation for ECG-gated spiral scanning with a 16-slice CT system.

Authors:  Th Flohr; B Ohnesorge; H Bruder; K Stierstorfer; J Simon; C Suess; S Schaller
Journal:  Med Phys       Date:  2003-10       Impact factor: 4.071

10.  Dual-energy CT of the heart for diagnosing coronary artery stenosis and myocardial ischemia-initial experience.

Authors:  Balazs Ruzsics; Heon Lee; Peter L Zwerner; Mulugeta Gebregziabher; Philip Costello; U Joseph Schoepf
Journal:  Eur Radiol       Date:  2008-06-04       Impact factor: 5.315

View more
  14 in total

1.  A strategy to decrease partial scan reconstruction artifacts in myocardial perfusion CT: phantom and in vivo evaluation.

Authors:  Juan C Ramirez-Giraldo; Lifeng Yu; Birgit Kantor; Erik L Ritman; Cynthia H McCollough
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  Comparison of image quality and radiation dose of different pulmonary CTA protocols on a 128-slice CT: high-pitch dual source CT, dual energy CT and conventional spiral CT.

Authors:  Tobias De Zordo; Klemens von Lutterotti; Christian Dejaco; Peter F Soegner; Renate Frank; Friedrich Aigner; Andrea S Klauser; Christoph Pechlaner; U Joseph Schoepf; Werner R Jaschke; Gudrun M Feuchtner
Journal:  Eur Radiol       Date:  2011-08-28       Impact factor: 5.315

3.  Dual energy bone subtraction in computed tomography angiography of extracranial-intracranial bypass: feasibility and limitations.

Authors:  André Kemmling; Ingo Nölte; Christoph Groden; Steffen Diehl
Journal:  Eur Radiol       Date:  2010-10-04       Impact factor: 5.315

Review 4.  Advances in myocardial CT perfusion imaging technology.

Authors:  Yan Yi; Zheng-Yu Jin; Yi-Ning Wang
Journal:  Am J Transl Res       Date:  2016-11-15       Impact factor: 4.060

5.  Dual-source multienergy CT with triple or quadruple x-ray beams.

Authors:  Lifeng Yu; Liqiang Ren; Zhoubo Li; Shuai Leng; Cynthia H McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2018-07-24

6.  A cascaded model of spectral distortions due to spectral response effects and pulse pileup effects in a photon-counting x-ray detector for CT.

Authors:  Jochen Cammin; Jennifer Xu; William C Barber; Jan S Iwanczyk; Neal E Hartsough; Katsuyuki Taguchi
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

7.  Detection and Characterization of Renal Stones by Using Photon-Counting-based CT.

Authors:  Roy P Marcus; Joel G Fletcher; Andrea Ferrero; Shuai Leng; Ahmed F Halaweish; Ralf Gutjahr; Terri J Vrtiska; Mike L Wells; Felicity T Enders; Cynthia H McCollough
Journal:  Radiology       Date:  2018-08-07       Impact factor: 11.105

8.  Deep learning based spectral extrapolation for dual-source, dual-energy x-ray computed tomography.

Authors:  Darin P Clark; Fides R Schwartz; Daniele Marin; Juan C Ramirez-Giraldo; Cristian T Badea
Journal:  Med Phys       Date:  2020-07-06       Impact factor: 4.071

9.  Plain Radiography May Be Safely Omitted for Selected Major Trauma Patients Undergoing Whole Body CT: Database Study.

Authors:  Sarah Hudson; Adrian Boyle; Stephanie Wiltshire; Lisa McGerty; Sara Upponi
Journal:  Emerg Med Int       Date:  2012-07-15       Impact factor: 1.112

Review 10.  Pushing CT and MR imaging to the molecular level for studying the "omics": current challenges and advancements.

Authors:  Hsuan-Ming Huang; Yi-Yu Shih
Journal:  Biomed Res Int       Date:  2014-03-13       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.