Literature DB >> 17659240

Detection of ductal carcinoma in situ with mammography, breast specific gamma imaging, and magnetic resonance imaging: a comparative study.

Rachel F Brem1, Michael Fishman, Jocelyn A Rapelyea.   

Abstract

RATIONALE AND
OBJECTIVES: To evaluate the sensitivity of high-resolution breast-specific gamma imaging (BSGI) for the detection of ductal carcinoma in situ (DCIS) based on histopathology and to compare the sensitivity of BSGI with mammography and magnetic resonance imaging (MRI) for the detection of DCIS.
MATERIALS AND METHODS: Twenty women, mean 55 years (range 34-76 years), with 22 biopsy-proven DCIS were retrospectively reviewed. After injection of 25-30 mCi (925-1,110 MBq) technetium 99m-sestamibi, patients had BSGI with a high-resolution, small-field-of-view gamma camera in craniocaudal and mediolateral oblique projections. BSGI studies were prospectively classified according to focal radiotracer uptake using a 1 to 5 scale, as normal 1), with no focal or diffuse uptake; benign 2), with minimal patchy uptake; probably benign 3), with scattered patchy uptake; probably abnormal 4), with mild focal radiotracer uptake; and abnormal 5), with marked focal radiotracer uptake. Imaging findings were compared to findings at biopsy or surgical excision. The sensitivity of BSGI, mammography, and when performed, MRI were determined for the detection of DCIS. Breast MRI was performed on seven patients with eight biopsy-proven foci. The sensitivities were compared using a two-tailed t-test and confidence intervals were determined.
RESULTS: Pathologic tumor size of the DCIS ranged from 2 to 21 mm (mean 9.9 mm). Of 22 cases of biopsy-proven DCIS in 20 women, 91% were detected with BSGI, 82% were detected with mammography, and 88% were detected with magnetic resonance imaging. BSGI had the highest sensitivity for the detection of DCIS, although this small sample size did not demonstrate a statistically significant difference. Two cases of DCIS (9%) were diagnosed only after BSGI demonstrated an occult focus of radiotracer uptake in the contralateral breast, previously undetected by mammography. There were two false-negative BSGI studies
CONCLUSIONS: BSGI has higher sensitivity for the detection of DCIS than mammography or MRI and can reliably detect small, subcentimeter lesions.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17659240     DOI: 10.1016/j.acra.2007.04.004

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  21 in total

1.  MRI of the breast in patients with DCIS to exclude the presence of invasive disease.

Authors:  Eline E Deurloo; Jincey D Sriram; Hendrik J Teertstra; Claudette E Loo; Jelle Wesseling; Emiel J Th Rutgers; Kenneth G A Gilhuijs
Journal:  Eur Radiol       Date:  2012-02-26       Impact factor: 5.315

2.  Preclinical evaluation of nuclear morphometry and tissue topology for breast carcinoma detection and margin assessment.

Authors:  Ndeke Nyirenda; Daniel L Farkas; V Krishnan Ramanujan
Journal:  Breast Cancer Res Treat       Date:  2010-05-06       Impact factor: 4.872

3.  Dual-modality breast tomosynthesis.

Authors:  Mark B Williams; Patricia G Judy; Spencer Gunn; Stanislaw Majewski
Journal:  Radiology       Date:  2010-04       Impact factor: 11.105

Review 4.  Mode of detection and secular time for ductal carcinoma in situ.

Authors:  Etta D Pisano
Journal:  J Natl Cancer Inst Monogr       Date:  2010

5.  Development of array piezoelectric fingers towards in vivo breast tumor detection.

Authors:  Xin Xu; Youngsoo Chung; Ari D Brooks; Wei-Heng Shih; Wan Y Shih
Journal:  Rev Sci Instrum       Date:  2016-12       Impact factor: 1.523

Review 6.  Preoperative imaging for breast conservation surgery-do we need more than conventional imaging for local disease assessment?

Authors:  Eugene Ong
Journal:  Gland Surg       Date:  2018-12

7.  Intratumoral metabolic heterogeneity predicts invasive components in breast ductal carcinoma in situ.

Authors:  Hai-Jeon Yoon; Yemi Kim; Bom Sahn Kim
Journal:  Eur Radiol       Date:  2015-06-11       Impact factor: 5.315

8.  Generation of a suite of 3D computer-generated breast phantoms from a limited set of human subject data.

Authors:  Christina M L Hsu; Mark L Palmeri; W Paul Segars; Alexander I Veress; James T Dobbins
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

Review 9.  Nuclear imaging of the breast: translating achievements in instrumentation into clinical use.

Authors:  Carrie B Hruska; Michael K O'Connor
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

Review 10.  Clinical usefulness of breast-specific gamma imaging as an adjunct modality to mammography for diagnosis of breast cancer: a systemic review and meta-analysis.

Authors:  Yu Sun; Wei Wei; Hua-Wei Yang; Jian-Lun Liu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-11-14       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.