Literature DB >> 25506042

18FDG-PET/CT Definition of Clinical Target Volume for Robotic Stereotactic Body Radiosurgery Treatment of Metastatic Gynecologic Malignancies.

Charles A Kunos1, Robert Debernardo2, Jeffrey Fabien1, Donald C Dobbins1, Yuxia Zhang1, James Brindle1, Peter F Faulhaber3.   

Abstract

The objective of the current article was to evaluate 2-[18F]fluoro-2-deoxy-D-glucose 18F-FDG) as measured by positron emission tomography for delineation of abdominopelvic gross tumor volumes (GTV) for stereotactic body radiosurgery treatment (SBRT) of metastatic gynecologic cancers. A retrospective review of SBRT was conducted in 27 women with stage IV gynecologic cancers recurring in para-aortic lymph nodes. Robotic SBRT involved 2400 cGy in 3 consecutive 800 cGy daily fractions prescribed to a 3.0 mm expanded planning tumor volume (PTV) defined by both CT-based and 18F-FDG-based GTVs. In this study, 18F-FDG-based GTVs led to significantly larger PTVs in all 27 women, than if they had been based on CT GTVs alone (P < 0.001). Enlarged PTVs may have resulted from the breathing-induced target motion during the time of 18F-FDG image acquisition smearing 18F-FDG signal over a greater anatomic dimension. Ultimately, SBRT-target local control, based on the RECIST 1.1 criteria, was 96% (26 of 27), and associated with minor reversible toxicity. The use of 18F-FDG to define SBRT target volumes warrants further interrogation in SBRT clinical trials.

Entities:  

Year:  2011        PMID: 25506042      PMCID: PMC4260799          DOI: 10.4172/2155-9619.s4-001

Source DB:  PubMed          Journal:  J Nucl Med Radiat Ther


  13 in total

Review 1.  The CyberKnife Robotic Radiosurgery System in 2010.

Authors:  W Kilby; J R Dooley; G Kuduvalli; S Sayeh; C R Maurer
Journal:  Technol Cancer Res Treat       Date:  2010-10

2.  The design, physical properties and clinical utility of an iris collimator for robotic radiosurgery.

Authors:  G G Echner; W Kilby; M Lee; E Earnst; S Sayeh; A Schlaefer; B Rhein; J R Dooley; C Lang; O Blanck; E Lessard; C R Maurer; W Schlegel
Journal:  Phys Med Biol       Date:  2009-08-18       Impact factor: 3.609

Review 3.  Emerging application of stereotactic body radiation therapy for gynecologic malignancies.

Authors:  Nina A Mayr; Zhibin Huang; Jason W Sohn; Simon S Lo; Bin S Teh; Jiade J Lu; John C Grecula; Charles Kunos
Journal:  Expert Rev Anticancer Ther       Date:  2011-07       Impact factor: 4.512

4.  Lymph node staging by positron emission tomography in patients with carcinoma of the cervix.

Authors:  P W Grigsby; B A Siegel; F Dehdashti
Journal:  J Clin Oncol       Date:  2001-09-01       Impact factor: 44.544

5.  Prospective evaluation of FDG-PET for detecting pelvic and para-aortic lymph node metastasis in uterine corpus cancer.

Authors:  Neil S Horowitz; Farrokh Dehdashti; Thomas J Herzog; Janet S Rader; Matthew A Powell; Randal K Gibb; Perry W Grigsby; Barry A Siegel; David G Mutch
Journal:  Gynecol Oncol       Date:  2004-12       Impact factor: 5.482

6.  18F-FDG PET definition of gross tumor volume for radiotherapy of non-small cell lung cancer: is a single standardized uptake value threshold approach appropriate?

Authors:  Kenneth J Biehl; Feng-Ming Kong; Farrokh Dehdashti; Jian-Yue Jin; Sasa Mutic; Issam El Naqa; Barry A Siegel; Jeffrey D Bradley
Journal:  J Nucl Med       Date:  2006-11       Impact factor: 10.057

7.  Uptake of 18F-labeled 6-fluoro-6-deoxy-D-glucose by skeletal muscle is responsive to insulin stimulation.

Authors:  Chandra Spring-Robinson; Visvanathan Chandramouli; William C Schumann; Peter F Faulhaber; Yanming Wang; Chunying Wu; Faramarz Ismail-Beigi; Raymond F Muzic
Journal:  J Nucl Med       Date:  2009-05-14       Impact factor: 10.057

8.  Cyberknife radiosurgery for squamous cell carcinoma of vulva after prior pelvic radiation therapy.

Authors:  Charles Kunos; Vivian von Gruenigen; Steven Waggoner; James Brindle; Yuxia Zhang; Brenda Myers; Gary Funkhouser; Barry Wessels; Douglas Einstein
Journal:  Technol Cancer Res Treat       Date:  2008-10

9.  Treatment planning guidelines regarding the use of CT/PET-guided IMRT for cervical carcinoma with positive paraaortic lymph nodes.

Authors:  Jacqueline Esthappan; Sasa Mutic; Robert S Malyapa; Perry W Grigsby; Imran Zoberi; Farrokh Dehdashti; Tom R Miller; Walter R Bosch; Daniel A Low
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-03-15       Impact factor: 7.038

10.  Evaluation of GAFCHROMIC EBT film for Cyberknife dosimetry.

Authors:  Ellen E Wilcox; George M Daskalov
Journal:  Med Phys       Date:  2007-06       Impact factor: 4.071

View more
  3 in total

1.  Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy.

Authors:  Charles A Kunos; Jeffrey M Fabien; John P Shanahan; Christine Collen; Thierry Gevaert; Kenneth Poels; Robbe Van den Begin; Benedikt Engels; Mark De Ridder
Journal:  J Vis Exp       Date:  2015-06-07       Impact factor: 1.355

2.  Phase I Trial of Carboplatin and Gemcitabine Chemotherapy and Stereotactic Ablative Radiosurgery for the Palliative Treatment of Persistent or Recurrent Gynecologic Cancer.

Authors:  Charles A Kunos; Tracy M Sherertz; Mazen Mislmani; Rodney J Ellis; Simon S Lo; Steven E Waggoner; Kristine M Zanotti; Karin Herrmann; Robert L Debernardo
Journal:  Front Oncol       Date:  2015-06-05       Impact factor: 6.244

3.  Phase II Clinical Trial of Robotic Stereotactic Body Radiosurgery for Metastatic Gynecologic Malignancies.

Authors:  Charles A Kunos; James Brindle; Steven Waggoner; Kristine Zanotti; Kimberly Resnick; Nancy Fusco; Ramon Adams; Robert Debernardo
Journal:  Front Oncol       Date:  2012-12-05       Impact factor: 6.244

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.