Literature DB >> 24049318

Comparative analysis between 5 mm and 7.5 mm collimators in CyberKnife radiosurgery for trigeminal neuralgia.

H Sudahar1, P G G Kurup, V Murali, J Velmurugan.   

Abstract

Trigeminal neuralgia (TN) is treated in CyberKnife (Accuray Inc, Sunnyvale, USA) with the 5 mm collimator whose dosimetric inaccuracy is higher than the other available collimators. The 7.5 mm collimator which is having less dosimetric uncertainty can be an alternative for 5 mm collimator provided the dose distribution with 7.5 mm collimator is acceptable. Aim of this study is to analyze the role of 7.5 mm collimator in CyberKnife treatment plans of TN. The treatment plans with 5 mm collimators were re-optimized with 7.5 mm collimator and a bi-collimator system (5 mm and 7.5 mm). The treatment plans were compared for target coverage, brainstem doses, and the dose to normal tissues. The target and brainstem doses were comparable. However, the conformity indices were 2.31 ± 0.52, 2.40 ± 0.87 and 2.82 ± 0.51 for 5 mm, bi-collimator (5mm and 7.5 mm), 7.5 mm collimator plans respectively. This shows the level of dose spillage in 7.5 mm collimator plans. The 6 Gy dose volumes in 7.5 mm plans were 1.53 and 1.34 times higher than the 5 mm plan and the bi-collimator plans respectively. The treatment time parameters were lesser for 7.5 mm collimators. Since, the normal tissue dose is pretty high in 7.5 mm collimator plans, the use of it in TN plans can be ruled out though the treatment time is lesser for these 7.5 mm collimator plans.

Entities:  

Keywords:  Collimators; CyberKnife; stereotactic radiosurgery; trigeminal neuralgia

Year:  2013        PMID: 24049318      PMCID: PMC3775035          DOI: 10.4103/0971-6203.116364

Source DB:  PubMed          Journal:  J Med Phys        ISSN: 0971-6203


  28 in total

1.  Measurements of the relative output factors for CyberKnife collimators.

Authors:  Cheng Yu; Gabor Jozsef; Michael L J Apuzzo; Zbigniew Petrovich
Journal:  Neurosurgery       Date:  2004-01       Impact factor: 4.654

2.  Glass rod detectors for small field, stereotactic radiosurgery dosimetric audit.

Authors:  J Perks; M Gao; V Smith; S Skubic; S Goetsch
Journal:  Med Phys       Date:  2005-03       Impact factor: 4.071

3.  Outcome for patients with essential trigeminal neuralgia treated with linear accelerator stereotactic radiosurgery.

Authors:  Marcos Antonio Dos Santos; José Bustos Pérez de Salcedo; José Angel Gutiérrez Diaz; Gorka Nagore; Felipe A Calvo; José Samblás; Hugo Marsiglia; Kita Sallabanda
Journal:  Stereotact Funct Neurosurg       Date:  2011-05-25       Impact factor: 1.875

4.  Preliminary results of 45 patients with trigeminal neuralgia treated with radiosurgery compared to hypofractionated stereotactic radiotherapy, using a dedicated linear accelerator.

Authors:  Mario Francesco Fraioli; Lidia Strigari; Chiara Fraioli; Mario Lecce; Damiano Lisciani
Journal:  J Clin Neurosci       Date:  2012-08-13       Impact factor: 1.961

5.  Prospective study of the short-term adverse effects of gamma knife radiosurgery.

Authors:  Samuel T Chao; Vipul V Thakkar; Gene H Barnett; Michael A Vogelbaum; Lilyana Angelov; Robert J Weil; Peter Rasmussen; Alwyn M Reuther; Betty Jamison; Gennady Neyman; John H Suh
Journal:  Technol Cancer Res Treat       Date:  2012-04

Review 6.  Facial pain: trigeminal neuralgia.

Authors:  K H Lee
Journal:  Ann Acad Med Singapore       Date:  1993-03       Impact factor: 2.473

7.  Gamma knife radiosurgery for trigeminal neuralgia: comparing the use of a 4-mm versus concentric 4- and 8-mm collimators.

Authors:  Andrew A Kanner; Gennady Neyman; John H Suh; Martin S Weinhous; Shih-Yuan Lee; Gene H Barnett
Journal:  Stereotact Funct Neurosurg       Date:  2004       Impact factor: 1.875

8.  Dosimetric characterization of CyberKnife radiosurgical photon beams using polymer gels.

Authors:  E Pantelis; C Antypas; L Petrokokkinos; P Karaiskos; P Papagiannis; M Kozicki; E Georgiou; L Sakelliou; I Seimenis
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

9.  Radiation mechanisms of pain control in classical trigeminal neuralgia.

Authors:  Alessandra Gorgulho
Journal:  Surg Neurol Int       Date:  2012-01-14

10.  Dose linearity and monitor unit stability of a G4 type cyberknife robotic stereotactic radiosurgery system.

Authors:  H Sudahar; P G G Kurup; V Murali; J Velmurugan
Journal:  J Med Phys       Date:  2012-01
View more
  1 in total

1.  Dosimetric and radiobiological comparison of CyberKnife M6™ InCise multileaf collimator over IRIS™ variable collimator in prostate stereotactic body radiation therapy.

Authors:  Vindu Kathriarachchi; Charles Shang; Grant Evans; Theodora Leventouri; Georgios Kalantzis
Journal:  J Med Phys       Date:  2016 Apr-Jun
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.