Relations between the bone density values from computerized tomography, and implant stability parameters: a clinical study of 230 regular platform implants.

Ilser Turkyilmaz1, Celal Tumer, Esma Nida Ozbek, Tolga F Tözüm.   

Abstract

AIMS: The objective of this study was to determine the relationship between bone density, insertion torque, and implant stability at implant placement.
MATERIALS AND METHODS: One-hundred and eight patients were treated with 230 Brånemark System implants. A computerized tomography (CT) machine was used for pre-operative evaluation of the jaw bone for each patient. The maximum insertion torque values were recorded with the OsseoCare equipment. Implant stability measurements were performed with the Osstell machine for only 142 implants.
RESULTS: The mean bone density and insertion torque values were 721+/-254 Hounsfield unit (HU) and 39.1+/-7 N cm for 230 implants, and the correlation was significant (r=0.664, p<0.001). The mean bone density, insertion torque, and resonance frequency analysis values were 751+/-257 HU, 39.4+/-7 Nc m, and 70.5+/-7 implant stability quotient (ISQ), respectively, for 142 implants. Statistically significant correlations were found between bone density and insertion torque values (p<0.001); bone density and ISQ values (p<0.001); and insertion torque and ISQ values (p<0.001).
CONCLUSION: The bone density values from pre-operative CT examination may provide an objective assessment of bone quality, and significant correlations between bone density and implant stability parameters may help clinicians to predict primary stability before implant insertion.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17635248     DOI: 10.1111/j.1600-051X.2007.01112.x

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  29 in total

1.  Relation between insertion torque and bone-implant contact percentage: an artificial bone study.

Authors:  Cheng Liu; Ming-Tzu Tsai; Heng-Li Huang; Michael Yuan-Chien Chen; Jui-Ting Hsu; Kuo-Chih Su; Chih-Han Chang; Aaron Yu-Jen Wu
Journal:  Clin Oral Investig       Date:  2012-01-10       Impact factor: 3.573

2.  Deriving Hounsfield units using grey levels in cone beam CT: a clinical application.

Authors:  T E Reeves; P Mah; W D McDavid
Journal:  Dentomaxillofac Radiol       Date:  2012-06-29       Impact factor: 2.419

3.  Ultralow dose dentomaxillofacial CT imaging and iterative reconstruction techniques: variability of Hounsfield units and contrast-to-noise ratio.

Authors:  Gerlig Widmann; Alexander Bischel; Andreas Stratis; Apoorv Kakar; Hilde Bosmans; Reinhilde Jacobs; Eva-Maria Gassner; Wolfgang Puelacher; Ruben Pauwels
Journal:  Br J Radiol       Date:  2016-01-21       Impact factor: 3.039

4.  CT-based evaluation of volumetric bone density in fragility fractures of the pelvis-a matched case-control analysis.

Authors:  D Schönenberg; R Guggenberger; D Frey; H-C Pape; H-P Simmen; G Osterhoff
Journal:  Osteoporos Int       Date:  2017-11-13       Impact factor: 4.507

5.  Evaluation of Bone Density Around the Implants Placed Using Drilling Technique and Bone Expansion Technique: An In vivo Study.

Authors:  G V K Mohan Reddy; C H Vamsi Krishna; S Lakshmi; Venkat Aditya; N Chandra Sekhar; Y Mahadev Shastry
Journal:  J Indian Prosthodont Soc       Date:  2013-08-04

6.  The effect of screw tunnels on the biomechanical stability of vertebral body after pedicle screws removal: a finite element analysis.

Authors:  Jia-Ming Liu; Yu Zhang; Yang Zhou; Xuan-Yin Chen; Shan-Hu Huang; Zi-Kai Hua; Zhi-Li Liu
Journal:  Int Orthop       Date:  2017-03-28       Impact factor: 3.075

7.  Variability of dental cone beam CT grey values for density estimations.

Authors:  R Pauwels; O Nackaerts; N Bellaiche; H Stamatakis; K Tsiklakis; A Walker; H Bosmans; R Bogaerts; R Jacobs; K Horner
Journal:  Br J Radiol       Date:  2013-01       Impact factor: 3.039

Review 8.  Evaluation of functional dynamics during osseointegration and regeneration associated with oral implants.

Authors:  Po-Chun Chang; Niklaus P Lang; William V Giannobile
Journal:  Clin Oral Implants Res       Date:  2010-01       Impact factor: 5.977

9.  Three-dimensional evaluation of the different donor sites of the mandible for autologous bone grafts.

Authors:  Stephan Christian Möhlhenrich; Nicole Heussen; Nassim Ayoub; Frank Hölzle; Ali Modabber
Journal:  Clin Oral Investig       Date:  2014-03-26       Impact factor: 3.573

10.  Mandibular cortical indices and their relation to gender and age in the cone-beam computed tomography.

Authors:  Samir Goyushov; Erhan Dursun; Tolga Fikret Tözüm
Journal:  Dentomaxillofac Radiol       Date:  2019-11-14       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.