Literature DB >> 17625940

Single loop multi-gap resonator for whole body EPR imaging of mice at 1.2 GHz.

Sergey Petryakov1, Alexandre Samouilov, Eric Kesselring, Tomasz Wasowicz, George L Caia, Jay L Zweier.   

Abstract

For whole body EPR imaging of small animals, typically low frequencies of 250-750 MHz have been used due to the microwave losses at higher frequencies and the challenges in designing suitable resonators to accommodate these large lossy samples. However, low microwave frequency limits the obtainable sensitivity. L-band frequencies can provide higher sensitivity, and have been commonly used for localized in vivo EPR spectroscopy. Therefore, it would be highly desirable to develop an L-band microwave resonator suitable for in vivo whole body EPR imaging of small animals such as living mice. A 1.2 GHz 16-gap resonator with inner diameter of 42 mm and 48 mm length was designed and constructed for whole body EPR imaging of small animals. The resonator has good field homogeneity and stability to animal-induced motional noise. Resonator stability was achieved with electrical and mechanical design utilizing a fixed position double coupling loop of novel geometry, thus minimizing the number of moving parts. Using this resonator, high quality EPR images of lossy phantoms and living mice were obtained. This design provides good sensitivity, ease of sample access, excellent stability and uniform B(1) field homogeneity for in vivo whole body EPR imaging of mice at 1.2 GHz.

Entities:  

Mesh:

Year:  2007        PMID: 17625940      PMCID: PMC2714052          DOI: 10.1016/j.jmr.2007.05.021

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  17 in total

1.  Electronically tunable surface-coil-type resonator for L-band EPR spectroscopy.

Authors:  H Hirata; T Walczak; H M Swartz
Journal:  J Magn Reson       Date:  2000-01       Impact factor: 2.229

2.  EPR/NMR co-imaging for anatomic registration of free-radical images.

Authors:  Guanglong He; Yuanmu Deng; Haihong Li; Periannan Kuppusamy; Jay L Zweier
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

3.  Imaging spin probe distribution in the tumor of a living mouse with 250 MHz EPR: correlation with BOLD MRI.

Authors:  Benjamin B Williams; Hania al Hallaq; G V R Chandramouli; Eugene D Barth; Jonathan N Rivers; Marta Lewis; Valeri E Galtsev; Gregory S Karczmar; Howard J Halpern
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

4.  Mapping of the B1 field distribution of a surface coil resonator using EPR imaging.

Authors:  Guanglong He; Sathesh P Evalappan; Hiroshi Hirata; Yuanmu Deng; Sergey Petryakov; Periannan Kuppusamy; Jay L Zweier
Journal:  Magn Reson Med       Date:  2002-12       Impact factor: 4.668

5.  Frequency dependence of EPR signal intensity, 250 MHz to 9.1 GHz.

Authors:  George A Rinard; Richard W Quine; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2002-05       Impact factor: 2.229

6.  Aqueous sample in an EPR cavity: sensitivity considerations.

Authors:  Yuri E Nesmelov; Anand Gopinath; David D Thomas
Journal:  J Magn Reson       Date:  2004-03       Impact factor: 2.229

7.  Frequency dependence of EPR signal intensity, 248 MHz to 1.4 GHz.

Authors:  George A Rinard; Richard W Quine; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2002-01       Impact factor: 2.229

8.  In vivo detection of a pH-sensitive nitroxide in the rat stomach by low-field ESR-based techniques.

Authors:  Margaret A Foster; Igor A Grigor'ev; David J Lurie; Valery V Khramtsov; Stephen McCallum; Ioannis Panagiotelis; James M S Hutchison; Andrei Koptioug; Ian Nicholson
Journal:  Magn Reson Med       Date:  2003-03       Impact factor: 4.668

Review 9.  Radio frequency continuous-wave and time-domain EPR imaging and Overhauser-enhanced magnetic resonance imaging of small animals: instrumental developments and comparison of relative merits for functional imaging.

Authors:  Sankaran Subramanian; Ken-Ichiro Matsumoto; James B Mitchell; Murali C Krishna
Journal:  NMR Biomed       Date:  2004-08       Impact factor: 4.044

10.  Development of a hybrid EPR/NMR coimaging system.

Authors:  Alexandre Samouilov; George L Caia; Eric Kesselring; Sergey Petryakov; Tomasz Wasowicz; Jay L Zweier
Journal:  Magn Reson Med       Date:  2007-07       Impact factor: 3.737

View more
  9 in total

1.  Segmented surface coil resonator for in vivo EPR applications at 1.1GHz.

Authors:  Sergey Petryakov; Alexandre Samouilov; Michael Chzhan-Roytenberg; Eric Kesselring; Ziqi Sun; Jay L Zweier
Journal:  J Magn Reson       Date:  2008-12-24       Impact factor: 2.229

2.  Compressed sensing of spatial electron paramagnetic resonance imaging.

Authors:  David H Johnson; Rizwan Ahmad; Guanglong He; Alexandre Samouilov; Jay L Zweier
Journal:  Magn Reson Med       Date:  2013-10-07       Impact factor: 4.668

3.  Dual frequency resonator for 1.2 GHz EPR/16.2 MHz NMR co-imaging.

Authors:  Sergey Petryakov; Alexandre Samouilov; Eric Kesselring; George L Caia; Ziqi Sun; Jay L Zweier
Journal:  J Magn Reson       Date:  2010-02-23       Impact factor: 2.229

4.  FLEXIBLE, WIRELESS, INDUCTIVELY COUPLED SURFACE COIL RESONATOR FOR EPR TOOTH DOSIMETRY.

Authors:  Wilson Schreiber; Sergey V Petryakov; Maciej M Kmiec; Matthew A Feldman; Paul M Meaney; Victoria A Wood; Holly K Boyle; Ann Barry Flood; Benjamin B Williams; Harold M Swartz
Journal:  Radiat Prot Dosimetry       Date:  2016-07-15       Impact factor: 0.972

5.  Organ specific mapping of in vivo redox state in control and cigarette smoke-exposed mice using EPR/NMR co-imaging.

Authors:  George L Caia; Olga V Efimova; Murugesan Velayutham; Mohamed A El-Mahdy; Tamer M Abdelghany; Eric Kesselring; Sergey Petryakov; Ziqi Sun; Alexandre Samouilov; Jay L Zweier
Journal:  J Magn Reson       Date:  2011-11-07       Impact factor: 2.229

6.  In vivo multisite oximetry using EPR-NMR coimaging.

Authors:  R Ahmad; G Caia; L C Potter; S Petryakov; P Kuppusamy; J L Zweier
Journal:  J Magn Reson       Date:  2010-08-24       Impact factor: 2.229

7.  Resonators for In Vivo Imaging: Practical Experience.

Authors:  George A Rinard; Richard W Quine; Laura A Buchanan; Sandra S Eaton; Gareth R Eaton; Boris Epel; Subramanian V Sundramoorthy; Howard J Halpern
Journal:  Appl Magn Reson       Date:  2017-09-22       Impact factor: 0.831

8.  Accelerated dynamic EPR imaging using fast acquisition and compressive recovery.

Authors:  Rizwan Ahmad; Alexandre Samouilov; Jay L Zweier
Journal:  J Magn Reson       Date:  2016-10-08       Impact factor: 2.229

9.  Development of an L-band resonator optimized for fast scan EPR imaging of the mouse head.

Authors:  Alexandre Samouilov; Denis Komarov; Sergey Petryakov; Arkadiy Iosilevich; Jay L Zweier
Journal:  Magn Reson Med       Date:  2021-05-03       Impact factor: 3.737

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.