Literature DB >> 19268615

Segmented surface coil resonator for in vivo EPR applications at 1.1GHz.

Sergey Petryakov1, Alexandre Samouilov, Michael Chzhan-Roytenberg, Eric Kesselring, Ziqi Sun, Jay L Zweier.   

Abstract

A four-loop segmented surface coil resonator (SSCR) with electronic frequency and coupling adjustments was constructed with 18mm aperture and loading capability suitable for in vivo Electron Paramagnetic Resonance (EPR) spectroscopy and imaging applications at L-band. Increased sample volume and loading capability were achieved by employing a multi-loop three-dimensional surface coil structure. Symmetrical design of the resonator with coupling to each loop resulted in high homogeneity of RF magnetic field. Parallel loops were coupled to the feeder cable via balancing circuitry containing varactor diodes for electronic coupling and tuning over a wide range of loading conditions. Manually adjusted high Q trimmer capacitors were used for initial tuning with subsequent tuning electronically controlled using varactor diodes. This design provides transparency and homogeneity of magnetic field modulation in the sample volume, while matching components are shielded to minimize interference with modulation and ambient RF fields. It can accommodate lossy samples up to 90% of its aperture with high homogeneity of RF and modulation magnetic fields and can function as a surface loop or a slice volume resonator. Along with an outer coaxial NMR surface coil, the SSCR enabled EPR/NMR co-imaging of paramagnetic probes in living rats to a depth of 20mm.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19268615      PMCID: PMC2919311          DOI: 10.1016/j.jmr.2008.12.014

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  17 in total

1.  Electronically tunable surface-coil-type resonator for L-band EPR spectroscopy.

Authors:  H Hirata; T Walczak; H M Swartz
Journal:  J Magn Reson       Date:  2000-01       Impact factor: 2.229

2.  Mapping of the B1 field distribution of a surface coil resonator using EPR imaging.

Authors:  Guanglong He; Sathesh P Evalappan; Hiroshi Hirata; Yuanmu Deng; Sergey Petryakov; Periannan Kuppusamy; Jay L Zweier
Journal:  Magn Reson Med       Date:  2002-12       Impact factor: 4.668

3.  Deconvolution algorithm based on automatic cutoff frequency selection for EPR imaging.

Authors:  Yuanmu Deng; Guanglong He; Periannan Kuppusamy; Jay L Zweier
Journal:  Magn Reson Med       Date:  2003-08       Impact factor: 4.668

4.  An improved external loop resonator for in vivo L-band EPR spectroscopy.

Authors:  Ildar Salikhov; Hiroshi Hirata; Tadeusz Walczak; Harold M Swartz
Journal:  J Magn Reson       Date:  2003-09       Impact factor: 2.229

Review 5.  In vitro and in vivo measurement of pH and thiols by EPR-based techniques.

Authors:  Valery V Khramtsov; Igor A Grigor'ev; Margaret A Foster; David J Lurie
Journal:  Antioxid Redox Signal       Date:  2004-06       Impact factor: 8.401

6.  Magnetic resonance imaging of biological specimens by electron paramagnetic resonance of nitroxide spin labels.

Authors:  J L Berliner; H Fujii
Journal:  Science       Date:  1985-02-01       Impact factor: 47.728

7.  Three-dimensional spectral-spatial EPR imaging of free radicals in the heart: a technique for imaging tissue metabolism and oxygenation.

Authors:  P Kuppusamy; M Chzhan; K Vij; M Shteynbuk; D J Lefer; E Giannella; J L Zweier
Journal:  Proc Natl Acad Sci U S A       Date:  1994-04-12       Impact factor: 11.205

8.  Electron paramagnetic resonance measurements of free radicals in the intact beating heart: a technique for detection and characterization of free radicals in whole biological tissues.

Authors:  J L Zweier; P Kuppusamy
Journal:  Proc Natl Acad Sci U S A       Date:  1988-08       Impact factor: 11.205

9.  A loop resonator for slice-selective in vivo EPR imaging in rats.

Authors:  Hiroshi Hirata; Guanglong He; Yuanmu Deng; Ildar Salikhov; Sergey Petryakov; Jay L Zweier
Journal:  J Magn Reson       Date:  2007-10-30       Impact factor: 2.229

10.  In vivo oxygen radical generation in the skin of the protoporphyria model mouse with visible light exposure: an L-band ESR study.

Authors:  Keizo Takeshita; Tokuko Takajo; Hiroshi Hirata; Mitsuhiro Ono; Hideo Utsumi
Journal:  J Invest Dermatol       Date:  2004-06       Impact factor: 8.551

View more
  3 in total

1.  Evaluation of a Refined Implantable Resonator for Deep-Tissue EPR Oximetry in the Clinic.

Authors:  Eunice Y Chen; Dan Tse; Huagang Hou; Wilson A Schreiber; Philip E Schaner; Maciej M Kmiec; Kendra A Hebert; Periannan Kuppusamy; Harold M Swartz; Benjamin B Williams
Journal:  Appl Magn Reson       Date:  2021-07-09       Impact factor: 0.974

2.  Resonators for In Vivo Imaging: Practical Experience.

Authors:  George A Rinard; Richard W Quine; Laura A Buchanan; Sandra S Eaton; Gareth R Eaton; Boris Epel; Subramanian V Sundramoorthy; Howard J Halpern
Journal:  Appl Magn Reson       Date:  2017-09-22       Impact factor: 0.831

3.  Development of an L-band resonator optimized for fast scan EPR imaging of the mouse head.

Authors:  Alexandre Samouilov; Denis Komarov; Sergey Petryakov; Arkadiy Iosilevich; Jay L Zweier
Journal:  Magn Reson Med       Date:  2021-05-03       Impact factor: 3.737

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.