Electronically tunable surface-coil-type resonator for L-band EPR spectroscopy.

H Hirata1, T Walczak, H M Swartz.   

Abstract

The automatic frequency control (AFC) circuit in conventional electron paramagnetic resonance (EPR) spectrometers automatically tunes the microwave source to the resonance frequency of the resonator. The circuit works satisfactorily for samples stable enough that the geometric relations in the resonance structure do not change in a significant way. When EPR signals are measured during in vivo experiments with small rodents, however, the distance between the signal source and the surface-coil detector can change rapidly. When a conventional AFC circuit keeps the oscillator tuned to the resonator under those conditions, the resultant frequency change may exceed +/-5 MHz and markedly shift the position of the EPR signal. Such a shift results in unacceptable effects on the spectra, especially when the experimenter is dealing with narrow EPR lines. The animal movement also causes a mismatching of the resonator and the 50-ohm transmission line. Direct results of this mismatching are increased noise; shifts in the position of the baseline; and a high probability of overdriving the signal preamplifier with consequent loss of the EPR signal. We therefore designed, built, and tested a new surface-coil resonator using varactor diodes for tuning the resonance frequency to the fixed frequency oscillator and for capacitive matching of the resonator to the 50-ohm transmission line. The performance of the automatic matching system was tested in vivo by measuring EPR spectra of lithium phthalocyanine implanted in rats. Stability and sensitivity of the spectrometer were evaluated by measuring EPR spectra with and without the use of the automatic matching system. The overall experimental performance of the spectrometer was found to significantly improve during in vivo experiments using the automatic matching system. Excellent matching between the 50-ohm transmission line and the resonator was maintained under all experimental circumstances that were tested. This should allow us now to carry out experiments that previously were not possible. Copyright 2000 Academic Press.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10617447     DOI: 10.1006/jmre.1999.1927

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  21 in total

1.  In vivo electron spin resonance spectroscopy: what use is it to gastroenterologists?

Authors:  N S Dhanjal; I J Cox; S D Taylor-Robinson
Journal:  Gut       Date:  2003-09       Impact factor: 23.059

2.  Automated on-the-fly detection and correction procedure for EPR imaging data acquisition.

Authors:  Rizwan Ahmad; Deepti S Vikram; Sergey Petryakov; Yuanmu Deng; Jay L Zweier; Periannan Kuppusamy; Bradley Clymer
Journal:  Magn Reson Med       Date:  2006-09       Impact factor: 4.668

3.  Single loop multi-gap resonator for whole body EPR imaging of mice at 1.2 GHz.

Authors:  Sergey Petryakov; Alexandre Samouilov; Eric Kesselring; Tomasz Wasowicz; George L Caia; Jay L Zweier
Journal:  J Magn Reson       Date:  2007-06-09       Impact factor: 2.229

4.  Segmented surface coil resonator for in vivo EPR applications at 1.1GHz.

Authors:  Sergey Petryakov; Alexandre Samouilov; Michael Chzhan-Roytenberg; Eric Kesselring; Ziqi Sun; Jay L Zweier
Journal:  J Magn Reson       Date:  2008-12-24       Impact factor: 2.229

5.  Experimental Procedures for Sensitive and Reproducible In Situ EPR Tooth Dosimetry.

Authors:  Benjamin B Williams; Artur Sucheta; Ruhong Dong; Yasuko Sakata; Akinori Iwasaki; Gregory Burke; Oleg Grinberg; Piotr Lesniewski; Maciej Kmiec; Harold M Swartz
Journal:  Radiat Meas       Date:  2007-07       Impact factor: 1.898

6.  Dual frequency resonator for 1.2 GHz EPR/16.2 MHz NMR co-imaging.

Authors:  Sergey Petryakov; Alexandre Samouilov; Eric Kesselring; George L Caia; Ziqi Sun; Jay L Zweier
Journal:  J Magn Reson       Date:  2010-02-23       Impact factor: 2.229

7.  FLEXIBLE, WIRELESS, INDUCTIVELY COUPLED SURFACE COIL RESONATOR FOR EPR TOOTH DOSIMETRY.

Authors:  Wilson Schreiber; Sergey V Petryakov; Maciej M Kmiec; Matthew A Feldman; Paul M Meaney; Victoria A Wood; Holly K Boyle; Ann Barry Flood; Benjamin B Williams; Harold M Swartz
Journal:  Radiat Prot Dosimetry       Date:  2016-07-15       Impact factor: 0.972

8.  Dynamic changes in oxygenation of intracranial tumor and contralateral brain during tumor growth and carbogen breathing: a multisite EPR oximetry with implantable resonators.

Authors:  Huagang Hou; Ruhong Dong; Hongbin Li; Benjamin Williams; Jean P Lariviere; S K Hekmatyar; Risto A Kauppinen; Nadeem Khan; Harold Swartz
Journal:  J Magn Reson       Date:  2011-10-01       Impact factor: 2.229

9.  Dynamic EPR Oximetry of Changes in Intracerebral Oxygen Tension During Induced Thromboembolism.

Authors:  Huagang Hou; Nadeem Khan; Sangeeta Gohain; Clifford J Eskey; Karen L Moodie; Kirk J Maurer; Harold M Swartz; Periannan Kuppusamy
Journal:  Cell Biochem Biophys       Date:  2017-04-22       Impact factor: 2.194

10.  Slow- and rapid-scan frequency-swept electrically detected magnetic resonance of MOSFETs with a non-resonant microwave probe within a semiconductor wafer-probing station.

Authors:  Duane J McCrory; Mark A Anders; Jason T Ryan; Pragya R Shrestha; Kin P Cheung; Patrick M Lenahan; Jason P Campbell
Journal:  Rev Sci Instrum       Date:  2019-01       Impact factor: 1.523

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.