Literature DB >> 20434379

Dual frequency resonator for 1.2 GHz EPR/16.2 MHz NMR co-imaging.

Sergey Petryakov1, Alexandre Samouilov, Eric Kesselring, George L Caia, Ziqi Sun, Jay L Zweier.   

Abstract

The development of a dual frequency resonator that enables both EPR and proton NMR imaging within the same resonator, magnet and gradient system is described. A novel design allows the same resonator to perform both EPR and proton NMR operation without moving resonator cables or switches. The resonator is capable of working at frequencies of 16.18 MHz for proton NMR and 1.2 GHz for EPR and is optimized for isolated rat heart experiments, measuring 22 mm in inner diameter and 19 mm in length. In EPR mode, the resonator functions as a one-loop-two gap resonator, electrically coupled through a half wavelength inverter. In NMR mode, it functions a single turn coil. Using the same loop for both modalities maximizes filling factor at both frequencies. Placing the tuning and switching controls away from the resonator prevents any inadvertent movement that would cause errors of EPR and NMR co-imaging registration. The resonator enabled good quality EPR and proton MRI of isolated rat hearts with precise registration. Copyright (c) 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20434379      PMCID: PMC2919297          DOI: 10.1016/j.jmr.2010.02.020

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  19 in total

1.  New experimental apparatus for multimodal resonance imaging: initial EPRI and NMRI experimental results.

Authors:  S Di Giuseppe; G Placidi; A Sotgiu
Journal:  Phys Med Biol       Date:  2001-04       Impact factor: 3.609

2.  Electronically tunable surface-coil-type resonator for L-band EPR spectroscopy.

Authors:  H Hirata; T Walczak; H M Swartz
Journal:  J Magn Reson       Date:  2000-01       Impact factor: 2.229

3.  EPR/NMR co-imaging for anatomic registration of free-radical images.

Authors:  Guanglong He; Yuanmu Deng; Haihong Li; Periannan Kuppusamy; Jay L Zweier
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

4.  First imaging results obtained with a multimodal apparatus combining low-field (35.7 mT) MRI and pulsed EPRI.

Authors:  Giuseppe Placidi; Marcello Alecci; Antonello Sotgiu
Journal:  Phys Med Biol       Date:  2002-05-21       Impact factor: 3.609

5.  Use of multi-coil parallel-gap resonators for co-registration EPR/NMR imaging.

Authors:  Yuuki Kawada; Hiroshi Hirata; Hirodata Fujii
Journal:  J Magn Reson       Date:  2006-10-06       Impact factor: 2.229

6.  Overhauser enhanced magnetic resonance imaging for tumor oximetry: coregistration of tumor anatomy and tissue oxygen concentration.

Authors:  Murali C Krishna; Sean English; Kenichi Yamada; John Yoo; Ramachandran Murugesan; Nallathamby Devasahayam; John A Cook; Klaes Golman; Jan Henrik Ardenkjaer-Larsen; Sankaran Subramanian; James B Mitchell
Journal:  Proc Natl Acad Sci U S A       Date:  2002-02-19       Impact factor: 11.205

7.  A loop resonator for slice-selective in vivo EPR imaging in rats.

Authors:  Hiroshi Hirata; Guanglong He; Yuanmu Deng; Ildar Salikhov; Sergey Petryakov; Jay L Zweier
Journal:  J Magn Reson       Date:  2007-10-30       Impact factor: 2.229

8.  Electron paramagnetic resonance oxygen image hypoxic fraction plus radiation dose strongly correlates with tumor cure in FSa fibrosarcomas.

Authors:  Martyna Elas; Rebecca Bell; Danielle Hleihel; Eugene D Barth; Colin McFaul; Chad R Haney; Joanna Bielanska; Katarzyna Pustelny; Kang-Hyun Ahn; Charles A Pelizzari; Masha Kocherginsky; Howard J Halpern
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-06-01       Impact factor: 7.038

9.  Large-scale synthesis of a persistent trityl radical for use in biomedical EPR applications and imaging.

Authors:  Ilirian Dhimitruka; Murugesan Velayutham; Andrey A Bobko; Valery V Khramtsov; Frederick A Villamena; Christopher M Hadad; Jay L Zweier
Journal:  Bioorg Med Chem Lett       Date:  2007-10-17       Impact factor: 2.823

10.  Development of a hybrid EPR/NMR coimaging system.

Authors:  Alexandre Samouilov; George L Caia; Eric Kesselring; Sergey Petryakov; Tomasz Wasowicz; Jay L Zweier
Journal:  Magn Reson Med       Date:  2007-07       Impact factor: 3.737

View more
  6 in total

1.  Fast gated EPR imaging of the beating heart: spatiotemporally resolved 3D imaging of free-radical distribution during the cardiac cycle.

Authors:  Zhiyu Chen; Levy A Reyes; David H Johnson; Murugesan Velayutham; Changjun Yang; Alexandre Samouilov; Jay L Zweier
Journal:  Magn Reson Med       Date:  2012-04-03       Impact factor: 4.668

2.  Organ specific mapping of in vivo redox state in control and cigarette smoke-exposed mice using EPR/NMR co-imaging.

Authors:  George L Caia; Olga V Efimova; Murugesan Velayutham; Mohamed A El-Mahdy; Tamer M Abdelghany; Eric Kesselring; Sergey Petryakov; Ziqi Sun; Alexandre Samouilov; Jay L Zweier
Journal:  J Magn Reson       Date:  2011-11-07       Impact factor: 2.229

3.  Proton-Electron Double-Resonance Imaging of pH using phosphonated trityl probe.

Authors:  Wataru Takahashi; Andrey A Bobko; Ilirian Dhimitruka; Hiroshi Hirata; Jay L Zweier; Alexandre Samouilov; Valery V Khramtsov
Journal:  Appl Magn Reson       Date:  2014-09-01       Impact factor: 0.831

4.  Uniform spinning sampling gradient electron paramagnetic resonance imaging.

Authors:  David H Johnson; Rizwan Ahmad; Yangping Liu; Zhiyu Chen; Alexandre Samouilov; Jay L Zweier
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

5.  Development of an L-band resonator optimized for fast scan EPR imaging of the mouse head.

Authors:  Alexandre Samouilov; Denis Komarov; Sergey Petryakov; Arkadiy Iosilevich; Jay L Zweier
Journal:  Magn Reson Med       Date:  2021-05-03       Impact factor: 3.737

6.  Merging Preclinical EPR Tomography with other Imaging Techniques.

Authors:  Michal Gonet; Boris Epel; Howard J Halpern; Martyna Elas
Journal:  Cell Biochem Biophys       Date:  2019-08-22       Impact factor: 2.194

  6 in total