X-ray scatter data for flat-panel detector CT.

Yiannis Kyriakou1, Willi A Kalender.   

Abstract

In modern X-ray computed tomography (CT) a trend to increased volume coverage by using multi-row detectors is apparent. Flat-panel detector CT (FPD-CT) systems provide an even larger field of measurement which, however, results in an increased scatter fraction. We investigated the scatter intensities registered in the case of FPD-CT. A hybrid model for the simulation of scatter combining deterministic and Monte Carlo methods was used for the scatter calculations. The influence of imaging parameters on the registered scatter intensity was examined both in single projections and reconstructed images. Scatter-to-primary ratios (SPRs) are given for various values of object thickness, field size, object-to-detector distance, incident energy and projection angle. For the simulations, homogeneous water phantoms and realistic patient data sets were used to produce scatter data representative for clinical situations. The SPR increases with object size, collimation and z-extent resulting in SPR>>1 and respective scatter artifacts in the reconstructed images. In contrary, the scatter intensity decreases non-linearly with the object-to-detector distance. The angular and spatial distributions of scatter form a flat function as compared to the distribution of the primary signal. Single scatter appears to determine the distribution and magnitude of the total-scatter intensity at the detector.

Entities:  

Mesh:

Year:  2007        PMID: 17568538     DOI: 10.1016/j.ejmp.2006.12.004

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  9 in total

1.  Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging.

Authors:  P Prakash; W Zbijewski; G J Gang; Y Ding; J W Stayman; J Yorkston; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  Evaluation of demineralized bone and bone transplants in vitro and in vivo with cone beam computed tomography imaging.

Authors:  F G Draenert; F Gebhart; M Berthold; M Gosau; W Wagner
Journal:  Dentomaxillofac Radiol       Date:  2010-07       Impact factor: 2.419

Review 3.  C-arm flat detector computed tomography: the technique and its applications in interventional neuro-radiology.

Authors:  Mudassar Kamran; Sanjoy Nagaraja; James V Byrne
Journal:  Neuroradiology       Date:  2009-10-27       Impact factor: 2.804

4.  Evaluation of 2D and 3D navigation for iliosacral screw fixation.

Authors:  Daniel Behrendt; Maria Mütze; Hanno Steinke; Martin Koestler; Christoph Josten; Jörg Böhme
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-09-18       Impact factor: 2.924

5.  Relationship between x-ray illumination field size and flat field intensity and its impacts on x-ray imaging.

Authors:  Xue Dong; Tianye Niu; Xun Jia; Lei Zhu
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

Review 6.  Cone-beam CT in paediatric dentistry: DIMITRA project position statement.

Authors:  Anne Caroline Oenning; Reinhilde Jacobs; Ruben Pauwels; Andreas Stratis; Mihaela Hedesiu; Benjamin Salmon
Journal:  Pediatr Radiol       Date:  2017-11-15

7.  Transmission characteristics of a two dimensional antiscatter grid prototype for CBCT.

Authors:  Cem Altunbas; Brian Kavanagh; Timur Alexeev; Moyed Miften
Journal:  Med Phys       Date:  2017-06-16       Impact factor: 4.071

8.  Truncation effect reduction for fast iterative reconstruction in cone-beam CT.

Authors:  Sorapong Aootaphao; Saowapak S Thongvigitmanee; Puttisak Puttawibul; Pairash Thajchayapong
Journal:  BMC Med Imaging       Date:  2022-09-05       Impact factor: 2.795

9.  X-Ray Scatter Correction on Soft Tissue Images for Portable Cone Beam CT.

Authors:  Sorapong Aootaphao; Saowapak S Thongvigitmanee; Jartuwat Rajruangrabin; Chalinee Thanasupsombat; Tanapon Srivongsa; Pairash Thajchayapong
Journal:  Biomed Res Int       Date:  2016-02-16       Impact factor: 3.411

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.