Literature DB >> 17568315

Uncorrected wavefront error and visual performance during RGP wear in keratoconus.

Jason D Marsack1, Katrina E Parker, Konrad Pesudovs, William J Donnelly, Raymond A Applegate.   

Abstract

PURPOSE: To examine the relationship between uncorrected residual wavefront error and visual performance (VP) in rigid gas permeable (RGP) contact lens-wearing keratoconic eyes.
METHODS: Seven eyes from six subjects (six moderate, one severe) were studied (mean +/- SD age: 42.71 +/- 11.38 years). Significant corneal scarring was an exclusion criterion. Measurements were taken with RGP lenses in place. After pupil dilation, the VP measures of high contrast logMAR visual acuity (VA) and Pelli-Robson contrast sensitivity (PRCS) were measured through a 5-mm artificial pupil. Wavefront error was measured using a Shack-Hartmann wavefront sensor and calculated over 5 mm. For both VP and wavefront error, comparisons were made to previously collected normal values by calculating the interval encompassing 95% of normals, then reporting how many of the seven keratoconic eyes fell outside the normal interval. Additionally, second to sixth order aberrations were processed into four previously reported image quality metrics: root mean square of the wavefront (RMSw), root mean square of the slope (RMSs), average blur strength (Bave) and diameter containing 50% light energy (D50) and regressed against VP measures.
RESULTS: Five of seven keratoconic eyes fell outside the normal interval (-0.23 to 0.09) for VA and two of seven fell outside the normal interval (1.59 to 2.03) for PRCS. Five of seven keratoconic eyes fell outside the normal interval (0.07 to 0.35 microm) for total higher order RMS. Linear regressions demonstrated relationships between both VA and PRCS and the image quality metrics RMSw, D50, RMSs, and Bave with R values for VA = 0.30, 0.30, 0.47, 0.62, and PRCS = 0.21, 0.15, 0.45, 0.75 respectively.
CONCLUSIONS: VP in RGP-wearing keratoconic eyes is reduced and higher order wavefront aberrations are elevated compared to normals. Metrics of retinal image quality demonstrate a relationship between keratoconic VP and residual wavefront aberrations. This relationship suggests developing corrections that more completely correct aberrations may improve visual performance in keratoconus.

Entities:  

Mesh:

Year:  2007        PMID: 17568315     DOI: 10.1097/OPX.0b013e31802e64f0

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  15 in total

1.  Optimizing wavefront-guided corrections for highly aberrated eyes in the presence of registration uncertainty.

Authors:  Yue Shi; Hope M Queener; Jason D Marsack; Ayeswarya Ravikumar; Harold E Bedell; Raymond A Applegate
Journal:  J Vis       Date:  2013-06-11       Impact factor: 2.240

2.  Change in visual acuity is well correlated with change in image-quality metrics for both normal and keratoconic wavefront errors.

Authors:  Ayeswarya Ravikumar; Jason D Marsack; Harold E Bedell; Yue Shi; Raymond A Applegate
Journal:  J Vis       Date:  2013-11-26       Impact factor: 2.240

3.  Bevel toric multicurve rigid gas-permeable lens for keratoconus.

Authors:  Ryoji Yanai; Kiichi Ueda; Koh-Hei Sonoda
Journal:  Jpn J Ophthalmol       Date:  2012-12-07       Impact factor: 2.447

4.  Binocular cross-correlation analyses of the effects of high-order aberrations on the stereoacuity of eyes with keratoconus.

Authors:  Sangeetha Metlapally; Shrikant R Bharadwaj; Austin Roorda; Vinay Kumar Nilagiri; Tiffanie T Yu; Clifton M Schor
Journal:  J Vis       Date:  2019-06-03       Impact factor: 2.240

5.  LogMAR and Stereoacuity in Keratoconus Corrected with Spectacles and Rigid Gas-permeable Contact Lenses.

Authors:  Vinay Kumar Nilagiri; Sangeetha Metlapally; Parthasarathi Kalaiselvan; Clifton M Schor; Shrikant R Bharadwaj
Journal:  Optom Vis Sci       Date:  2018-04       Impact factor: 1.973

6.  Template-based correction of high-order aberration in keratoconus.

Authors:  Jason D Marsack; Jos J Rozema; Carina Koppen; Marie-Jose Tassignon; Raymond A Applegate
Journal:  Optom Vis Sci       Date:  2013-04       Impact factor: 1.973

7.  Performance of wavefront-guided soft lenses in three keratoconus subjects.

Authors:  Jason D Marsack; Katrina E Parker; Raymond A Applegate
Journal:  Optom Vis Sci       Date:  2008-12       Impact factor: 1.973

8.  Wavefront-guided scleral lens prosthetic device for keratoconus.

Authors:  Ramkumar Sabesan; Lynette Johns; Olga Tomashevskaya; Deborah S Jacobs; Perry Rosenthal; Geunyoung Yoon
Journal:  Optom Vis Sci       Date:  2013-04       Impact factor: 1.973

9.  Posterior corneal aberrations and their compensation effects on anterior corneal aberrations in keratoconic eyes.

Authors:  Minghan Chen; Geunyoung Yoon
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-07-18       Impact factor: 4.799

10.  Wavefront-guided scleral lens correction in keratoconus.

Authors:  Jason D Marsack; Ayeswarya Ravikumar; Chi Nguyen; Anita Ticak; Darren E Koenig; James D Elswick; Raymond A Applegate
Journal:  Optom Vis Sci       Date:  2014-10       Impact factor: 1.973

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.