Comparative Evaluation of Dimensional Accuracy of Elastomeric Impression Materials when Treated with Autoclave, Microwave, and Chemical Disinfection.

Suresh S Kamble1, Rakshit Vijay Khandeparker2, P Somasundaram3, Shweta Raghav4, Rashmi P Babaji5, T Joju Varghese6.   

Abstract

BACKGROUND: Impression materials during impression procedure often get infected with various infectious diseases. Hence, disinfection of impression materials with various disinfectants is advised to protect the dental team. Disinfection can alter the dimensional accuracy of impression materials. The present study was aimed to evaluate the dimensional accuracy of elastomeric impression materials when treated with different disinfectants; autoclave, chemical, and microwave method.
MATERIALS AND METHODS: The impression materials used for the study were, dentsply aquasil (addition silicone polyvinylsiloxane syringe and putty), zetaplus (condensation silicone putty and light body), and impregum penta soft (polyether). All impressions were made according to manufacturer's instructions. Dimensional changes were measured before and after different disinfection procedures. RESULT: Dentsply aquasil showed smallest dimensional change (-0.0046%) and impregum penta soft highest linear dimensional changes (-0.026%). All the tested elastomeric impression materials showed some degree of dimensional changes.
CONCLUSION: The present study showed that all the disinfection procedures produce minor dimensional changes of impression material. However, it was within American Dental Association specification. Hence, steam autoclaving and microwave method can be used as an alternative method to chemical sterilization as an effective method.

Entities:  

Keywords:  Autoclave; chemical; dimensional changes; elastomeric; impression material; microwave

Year:  2015        PMID: 26435611      PMCID: PMC4589713     

Source DB:  PubMed          Journal:  J Int Oral Health        ISSN: 0976-1799


Introduction

Impression procedures are required for various dental procedures to make accurate casts of oral structures. During impression procedure, impression materials often come in contact with saliva and blood, which may get infected with infectious diseases such as AIDS, herpes, hepatitis, or tuberculosis. Hence, disinfection of impression materials is important as dentist, oral hygienist, and dental laboratory person often expose to infectious diseases.1-4 In 1998, FDI guidelines suggested that all impression materials should be disinfected before sending to laboratory.3 Even American Dental Association (ADA) and center for disease control suggested disinfection of impression materials to prevent cross infection.5 Disinfection can be done by either immersion or spraying impression materials with disinfectants.4 Disinfectants used should be as effective as antimicrobial agents, and not adversely affect the dimensional accuracy of impression material.1 Various disinfectants are advised for disinfecting impression materials such as, sodium hypochlorite, glutaraldehyde, iodophor, and phenol.1,5 According to the organization for safety and asepsis procedures, 10-15 min exposure of disinfectants is recommended.5 These chemicals can kill bacteria but not spores, hence sterilization by means of autoclaving and microwave methods are suggested. Autoclaving is one of the most effective methods of sterilization. Studies related to the accuracy of elastomeric impression materials after autoclaving is very scares.2,4 Addition silicone elastomeric impression materials (polyvinylsiloxane) are widely used because of their excellent dimensional accuracy with minimal distortion.4 It has been thought that disinfectants can alter the dimensional accurate of impression materials. Hence, the purpose of this study was to evaluate and compare the dimensional accuracy of elastomeric impression materials when treated with autoclave, microwave, and chemical disinfection.

Materials and Methods

This study uses three different types of impression materials; dentsply aquasil (addition type), zetaplus (condensation type), and impregum penta soft (polyether type) (Table 1). 30 impressions with 10 for each group impression materials were made according to manufacturer’s instructions. The stainless steel die was used according to ADA specification no.19 and ISO International standard 4823 to fabricate specimens.4-6 The syringe material was dispensed directly from cartridge on surface, and the tray material was placed over light body material.
Table 1

Elastomeric impression materials used in present study.

Elastomeric impression materials used in present study. The mold consisted of a base was scored with 3 horizontal lines perpendicular to 2 vertical lines with each 0.050 mm wide. 3.8 mm internal diameter steel ring was positioned accurately on the base and perforated steel plate was used to apply pressure after loading elastomers. Initially, the metal ring was placed on the base of the mold fallowed by direct injection of light body material onto platform. Then tray material was mixed and loaded according to manufacturer instruction. Excess materials were removed through perforation. The specimens were allowed to set in thermostatically controlled water bath at 37°C to simulate oral condition. Total of 30 specimens with 10 for each group (materials) were fabricated. After fabricating the samples, the distance between the inner profiles of horizontal line was measured (0.005 mm) using microscope before and after subjecting to disinfection with autoclave (Group-1), chemical - 1% sodium hypochlorite (Group-2), and microwave (Group-3) methods by same examiner. Mean values were tabulated and analyzed using t-test and SPSS software IBM version 21. The percentage of dimensional change was assessed using formula; dimensional change % = (A-B)/A × 100, where “A” is distance between the inner profile of horizontal line before disinfection and “B” is after disinfection procedure.

Results

The Tables 2 indicates % of linear dimensional change of different elastomeric materials after different disinfection procedures dentsply aquasil showed smallest dimensional change (−0.0046%) and impregum penta soft highest linear dimensional changes (−0.026%). With chemical disinfection linear expansion occurred. Highest contraction occurred with microwave method compared to autoclave and chemical type. The Tables 3 indicates dimensional change of different elastomeric materials after different disinfection procedures. All the tested elastomeric impression materials showed some degree of dimensional changes (Table 3).
Table 2

Linear dimensional changes (%) of impression materials after disinfection procedure.

Table 3

Mean and standard deviation of elastomeric materials after disinfection.

Linear dimensional changes (%) of impression materials after disinfection procedure. Mean and standard deviation of elastomeric materials after disinfection.

Discussion

Accurate reproduction of surface details of the oral structure is must after impression making. Disinfection of impression materials is advised to avoid cross infection. Impression materials may show dimensional changes after disinfection. Chemical disinfection alone is insufficient hence autoclave at high temperature is necessary to kill microbes and their spores. Microwave sterilization is used as an alternative approach, where electromagnetic energy from the microwave is considered to be alternative to the conventional method.4 This study measures the dimensional changes of impression materials after chemical, autoclave, and microwave sterilization. In the present study, microwaving method showed highest dimensional changes followed by autoclave method and chemical sterilization (Tables 2 and 3). This could be because of elastomer fluid intake in microwave method and dry nature of microwave. Results of our studies are similar to studies by Ramakrishnaiah et al. 2012 and Cynthia et al. 2003.4,7 Warden et al. from their study concluded that steam autoclaving of impression is a safe method of microbial reduction.8 Thota et al. from their study suggested that autoclave disinfection is effective for addition and condensation silicon, compare to polyether since polyether is hydrophilic which has to be disinfected by chemical means.2 Chemical disinfection produced minimal dimensional changes compared to other two methods. Tullner et al. observed no clinical significant dimensional changes with disinfection using 2% gluteraldehyde.9 Ivanis et al. (2000) concluded that polyether expanded with chlorhexidine 0.5% disinfection compared to addition and condensation type.10 Ahila and Subramanian. (2012) observed no significant dimensional changes after disinfecting impression materials with glutaraldehyde, povidone, and sodium hypochlorite.3 Katyayan et al. (2011) and Walker et al. (2007) concluded that dimensional changes of elastomer was within ADA specification after disinfection with phenol and 0.5% sodium hypochlorite.5,11 Similar results were observed by Guiraldo et al. (2012); Dorner et al. (2014); Garrofé et al. (2011).1,12,13 It has been observed that elastomer expand with chemical sterilization and contract with autoclave and microwave method.4 All of the tested impression materials were quite accurate before disinfection, but showed some degree of dimensional changes after disinfection. These dimensional changes is well below the ADA specification slandered <0.5%.

Conclusion

The present study showed that all the disinfection procedures produce minor dimensional changes of impression material. However, it is within ADA specification. Hence, steam autoclaving and microwave method can be used as an alternative method to chemical sterilization as an effective method.
  7 in total

1.  Linear dimensional stability of elastomeric impression materials over time.

Authors:  Analía B Garrofé; Beatriz A Ferrari; Mariana Picca; Andrea E Kaplan
Journal:  Acta Odontol Latinoam       Date:  2011

2.  A comparative evaluation of the dimensional stability of three different elastomeric impression materials after autoclaving - an invitro study.

Authors:  Kiran Kumar Thota; Sujana Jasthi; Rajyalakshmi Ravuri; Suchita Tella
Journal:  J Clin Diagn Res       Date:  2014-10-20

3.  Linear dimensional changes in dental impressions after immersion in disinfectant solutions.

Authors:  J B Tullner; J A Commette; P C Moon
Journal:  J Prosthet Dent       Date:  1988-12       Impact factor: 3.426

4.  Surface detail reproduction and dimensional accuracy of stone models: influence of disinfectant solutions and alginate impression materials.

Authors:  Ricardo Danil Guiraldo; Thaís Teixeira Borsato; Sandrine Bittencourt Berger; Murilo Baena Lopes; Alcides Gonini; Mário Alexandre Coelho Sinhoreti
Journal:  Braz Dent J       Date:  2012

5.  Dimensional accuracy and detail reproduction of two hydrophilic vinyl polysiloxane impression materials tested under different conditions.

Authors:  Preeti Agarwal Katyayan; Natarajan Kalavathy; Manish Katyayan
Journal:  Indian J Dent Res       Date:  2011 Nov-Dec

6.  Dimensional accuracy and surface detail reproduction of two hydrophilic vinyl polysiloxane impression materials tested under dry, moist, and wet conditions.

Authors:  Cynthia S Petrie; Mary P Walker; Aisling M O'mahony; Paulette Spencer
Journal:  J Prosthet Dent       Date:  2003-10       Impact factor: 3.426

7.  Surface quality and long-term dimensional stability of current elastomeric impression materials after disinfection.

Authors:  Mary P Walker; Meagan Rondeau; Cynthia Petrie; Amy Tasca; Karen Williams
Journal:  J Prosthodont       Date:  2007-06-09       Impact factor: 2.752

  7 in total
  3 in total

1.  Evaluation of surface detail reproduction, dimensional stability and gypsum compatibility of monophase polyvinyl-siloxane and polyether elastomeric impression materials under dry and moist conditions.

Authors:  Sriharsha Babu Vadapalli; Kaleswararao Atluri; Madhu Sudhan Putcha; Sirisha Kondreddi; N Suman Kumar; Durga Prasad Tadi
Journal:  J Int Soc Prev Community Dent       Date:  2016 Jul-Aug

2.  Comparison of disinfectants by immersion and spray atomization techniques on the linear dimensional stability of different interocclusal recording materials: An in vitro study.

Authors:  Revathy Gounder; B V J Vikas
Journal:  Eur J Dent       Date:  2016 Jan-Mar

Review 3.  Effect of chemical, microwave irradiation, steam autoclave, ultraviolet light radiation, ozone and electrolyzed oxidizing water disinfection on properties of impression materials: A systematic review and meta-analysis study.

Authors:  Sahar AlZain
Journal:  Saudi Dent J       Date:  2019-12-23
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.