Literature DB >> 17555237

Nonparametric ROC and LROC analysis.

Lucretiu M Popescu1.   

Abstract

In this paper we review several results of the nonparametric receiver operating characteristic (ROC) analysis and present an extension to the nonparametric localization ROC (LROC) analysis. Equations for the estimation of the area under the characteristic curve and for the variance calculations are derived. Expressions for the choice of the optimal ratio between the number of signal-absent and signal-present image samples are also presented. The results can be applied both with continuous or discrete scoring scales. The simulation studies carried out validate the theoretical derivations and show that the LROC analysis is considerably more sensitive than the ROC analysis.

Mesh:

Year:  2007        PMID: 17555237     DOI: 10.1118/1.2717407

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  A nonparametric procedure for comparing the areas under correlated LROC curves.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  IEEE Trans Med Imaging       Date:  2012-06-18       Impact factor: 10.048

2.  Model for the detection of signals in images with multiple suspicious locations.

Authors:  Lucreţiu M Popescu
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

3.  Effect of Using 2mm Voxels on Observer Performance for PET Lesion Detection.

Authors:  A Michael Morey; Frédéric Noo; Dan J Kadrmas
Journal:  IEEE Trans Nucl Sci       Date:  2016-04-28       Impact factor: 1.679

4.  Deep-learning-based model observer for a lung nodule detection task in computed tomography.

Authors:  Hao Gong; Qiyuan Hu; Andrew Walther; Chi Wan Koo; Edwin A Takahashi; David L Levin; Tucker F Johnson; Megan J Hora; Shuai Leng; Joel G Fletcher; Cynthia H McCollough; Lifeng Yu
Journal:  J Med Imaging (Bellingham)       Date:  2020-06-30

5.  Effect of Scan Time on Oncologic Lesion Detection in Whole-Body PET.

Authors:  Dan J Kadrmas; M Bugrahan Oktay; Michael E Casey; James J Hamill
Journal:  IEEE Trans Nucl Sci       Date:  2012-10       Impact factor: 1.679

6.  ROC or FROC? It depends on the research question.

Authors:  Stephen L Hillis; Dev P Chakraborty; Colin G Orton
Journal:  Med Phys       Date:  2017-03-17       Impact factor: 4.071

Review 7.  New developments in observer performance methodology in medical imaging.

Authors:  Dev P Chakraborty
Journal:  Semin Nucl Med       Date:  2011-11       Impact factor: 4.446

8.  Impact of time-of-flight on PET tumor detection.

Authors:  Dan J Kadrmas; Michael E Casey; Maurizio Conti; Bjoern W Jakoby; Cristina Lois; David W Townsend
Journal:  J Nucl Med       Date:  2009-07-17       Impact factor: 10.057

9.  Correlation between model observer and human observer performance in CT imaging when lesion location is uncertain.

Authors:  Shuai Leng; Lifeng Yu; Yi Zhang; Rickey Carter; Alicia Y Toledano; Cynthia H McCollough
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

10.  Relationship between Roe and Metz simulation model for multireader diagnostic data and Obuchowski-Rockette model parameters.

Authors:  Stephen L Hillis
Journal:  Stat Med       Date:  2018-04-02       Impact factor: 2.373

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.