Degenerate mode band-pass birdcage coil for accelerated parallel excitation.

Vijayanand Alagappan1, Juergen Nistler, Elfar Adalsteinsson, Kawin Setsompop, Ulrich Fontius, Adam Zelinski, Markus Vester, Graham C Wiggins, Franz Hebrank, Wolfgang Renz, Franz Schmitt, Lawrence L Wald.   

Abstract

An eight-rung, 3T degenerate birdcage coil (DBC) was constructed and evaluated for accelerated parallel excitation of the head with eight independent excitation channels. Two mode configurations were tested. In the first, each of the eight loops formed by the birdcage was individually excited, producing an excitation pattern similar to a loop coil array. In the second configuration a Butler matrix transformed this "loop coil" basis set into a basis set representing the orthogonal modes of the birdcage coil. In this case the rung currents vary sinusoidally around the coil and only four of the eight modes have significant excitation capability (the other four produce anticircularly polarized (ACP) fields). The lowest useful mode produces the familiar uniform B(1) field pattern, and the higher-order modes produce center magnitude nulls and azimuthal phase variations. The measured magnitude and phase excitation profiles of the individual modes were used to generate one-, four-, six-, and eightfold-accelerated spatially tailored RF excitations with 2D and 3D k-space excitation trajectories. Transmit accelerations of up to six-fold were possible with acceptable levels of spatial artifact. The orthogonal basis set provided by the Butler matrix was found to be advantageous when an orthogonal subset of these modes was used to mitigate B(1) transmit inhomogeneities using parallel excitation.

Mesh:

Year:  2007        PMID: 17534905     DOI: 10.1002/mrm.21247

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

1.  A nested phosphorus and proton coil array for brain magnetic resonance imaging and spectroscopy.

Authors:  Ryan Brown; Karthik Lakshmanan; Guillaume Madelin; Prodromos Parasoglou
Journal:  Neuroimage       Date:  2015-09-13       Impact factor: 6.556

2.  Broadband slab selection with B1+ mitigation at 7T via parallel spectral-spatial excitation.

Authors:  Kawin Setsompop; Vijayanand Alagappan; Borjan A Gagoski; Andreas Potthast; Franz Hebrank; Ulrich Fontius; Franz Schmitt; L L Wald; E Adalsteinsson
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

3.  Simultaneous z-shim method for reducing susceptibility artifacts with multiple transmitters.

Authors:  Weiran Deng; Cungeng Yang; Vijayanand Alagappan; Lawrence L Wald; Fernando E Boada; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

4.  Pushing the limits of in vivo diffusion MRI for the Human Connectome Project.

Authors:  K Setsompop; R Kimmlingen; E Eberlein; T Witzel; J Cohen-Adad; J A McNab; B Keil; M D Tisdall; P Hoecht; P Dietz; S F Cauley; V Tountcheva; V Matschl; V H Lenz; K Heberlein; A Potthast; H Thein; J Van Horn; A Toga; F Schmitt; D Lehne; B R Rosen; V Wedeen; L L Wald
Journal:  Neuroimage       Date:  2013-05-24       Impact factor: 6.556

5.  Comparison of simulated parallel transmit body arrays at 3 T using excitation uniformity, global SAR, local SAR, and power efficiency metrics.

Authors:  Bastien Guérin; Matthias Gebhardt; Peter Serano; Elfar Adalsteinsson; Michael Hamm; Josef Pfeuffer; Juergen Nistler; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-04-18       Impact factor: 4.668

6.  Array-compressed parallel transmit pulse design.

Authors:  Zhipeng Cao; Xinqiang Yan; William A Grissom
Journal:  Magn Reson Med       Date:  2015-10-28       Impact factor: 4.668

7.  Accelerated radiation damping for increased spin equilibrium (ARISE): a new method for controlling the recovery of longitudinal magnetization.

Authors:  Susie Y Huang; Thomas Witzel; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2008-11       Impact factor: 4.668

Review 8.  Massively parallel MRI detector arrays.

Authors:  Boris Keil; Lawrence L Wald
Journal:  J Magn Reson       Date:  2013-02-07       Impact factor: 2.229

9.  Specific absorption rate studies of the parallel transmission of inner-volume excitations at 7T.

Authors:  Adam C Zelinski; Leonardo M Angelone; Vivek K Goyal; Giorgio Bonmassar; Elfar Adalsteinsson; Lawrence L Wald
Journal:  J Magn Reson Imaging       Date:  2008-10       Impact factor: 4.813

10.  Optimizing the ICE decoupling element distance to improve monopole antenna arrays for 7 Tesla MRI.

Authors:  Xinqiang Yan; Xiaoliang Zhang; Rong Xue; John C Gore; William A Grissom
Journal:  Magn Reson Imaging       Date:  2016-07-25       Impact factor: 2.546

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.