Left ventricular dual-energy digital subtraction angiography: a motion immune digital subtraction technique.

M S Van Lysel1, W P Miller, D G Senior, V K Gupta, D J Ende, D J Albright.   

Abstract

Digital subtraction angiography (DSA) allows quantitative analysis of ventricular function via densitometric and parametric imaging techniques. However, DSA is limited by the artifacts in temporal subtraction images that result from patient and cardiac motion. Dual-energy subtraction imaging is insensitive to motion. This study evaluated the initial application of dual-energy subtraction in cardiac patients. The image quality of dual-energy subtraction left ventriculograms obtained from a pulmonary artery injection of contrast was assessed in 13 patients, ranging in weight from 54 to 100 kg. The dual-energy images were compared with left ventricular images obtained using standard left ventricular injection cine angiography. End-systolic and end-diastolic ventricular volumes calculated from the cine (C) and dual-energy (DE) images using the Area-Length method were compared. The resulting regression line was DE = 0.98 C+ 7.0 ml, and the r value was 0.987. Dual-energy subtraction provided good left ventricular visualization, free from misregistration artifacts, even during patient motion.

Entities:  

Mesh:

Year:  1991        PMID: 1753160     DOI: 10.1007/bf01797681

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  22 in total

1.  An algorithm for noise suppression in dual energy CT material density images.

Authors:  W A Kalender; E Klotz; L Kostaridou
Journal:  IEEE Trans Med Imaging       Date:  1988       Impact factor: 10.048

2.  The use of single plane angiocardiograms for the calculation of left ventricular volume in man.

Authors:  H Sandler; H T Dodge
Journal:  Am Heart J       Date:  1968-03       Impact factor: 4.749

3.  Left ventricular volume and mass from single-plane cineangiocardiogram. A comparison of anteroposterior and right anterior oblique methods.

Authors:  J W Kennedy; S E Trenholme; I S Kasser
Journal:  Am Heart J       Date:  1970-09       Impact factor: 4.749

4.  Determination of left ventricular ejection fraction by computer densitometric analysis of digital subtraction angiography: experimental validation and correlation with area-length methods.

Authors:  S E Nissen; J L Elion; P Grayburn; D C Booth; T W Wisenbaugh; A N DeMaria
Journal:  Am J Cardiol       Date:  1987-03-01       Impact factor: 2.778

5.  Evaluation of left ventricular contractile pattern by intravenous digital subtraction ventriculography: comparison with cineangiography and assessment of interobserver variability.

Authors:  S E Nissen; D Booth; J Waters; T Fassas; A N DeMaria
Journal:  Am J Cardiol       Date:  1983-12-01       Impact factor: 2.778

6.  Measurement of left ventricular ejection fraction by videodensitometric analysis of digital subtraction angiograms.

Authors:  J Tobis; O Nalcioglu; A Seibert; W D Johnston; W L Henry
Journal:  Am J Cardiol       Date:  1983-10-01       Impact factor: 2.778

7.  Left ventricular imaging with digital subtraction angiography using intravenous contrast injection and fluoroscopic exposure levels.

Authors:  J Tobis; O Nacioglu; W D Johnston; A Seibert; L T Iseri; W Roeck; U Elkayam; W L Henry
Journal:  Am Heart J       Date:  1982-07       Impact factor: 4.749

8.  Generalized image combinations in dual KVP digital radiography.

Authors:  L A Lehmann; R E Alvarez; A Macovski; W R Brody; N J Pelc; S J Riederer; A L Hall
Journal:  Med Phys       Date:  1981 Sep-Oct       Impact factor: 4.071

9.  Feasibility, reliability, and advantage of utilizing low contrast dose digital subtraction ventriculography in a conventional catheterization laboratory.

Authors:  S J Denardo; D J Anderson; R G Gould; M J Lipton; B H Brundage; T A Ports
Journal:  Am Heart J       Date:  1985-09       Impact factor: 4.749

10.  Real-time digital K-edge subtraction fluoroscopy.

Authors:  T L Houk; R A Kruger; C A Mistretta; S J Riederer; C G Shaw; J C Lancaster; D C Flemming
Journal:  Invest Radiol       Date:  1979 Jul-Aug       Impact factor: 6.016

View more
  1 in total

1.  Improved densitometric measurement of left ventricular ejection fraction using dual-energy digital subtraction angiography.

Authors:  M S van Lysel; W P Miller; T P Fuerst; D J Albright
Journal:  Int J Card Imaging       Date:  1994-06
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.