Improved densitometric measurement of left ventricular ejection fraction using dual-energy digital subtraction angiography.

M S van Lysel1, W P Miller, T P Fuerst, D J Albright.   

Abstract

The effects of misregistration artifacts and background corrections on the densitometric measurement of left ventricular ejection fraction (EF) from digital subtraction angiography (DSA) images were studied in 20 patients. Densitometric ejection fraction measurements were performed on both conventional time subtraction images and on dual-energy subtraction images. Dual-energy subtraction is not sensitive to the motion induced artifacts which often mar time subtraction images. While the time subtraction images had varying degrees of misregistration artifacts, none of the dual-energy studies contained significant misregistration artifacts. Densitometrically determined ejection fractions measured with and without correction for background signals were compared. Poor agreement between time subtraction ejection fractions determined with and without background correction (EFNO-BKG = 0.88 EFBKG - 6.0%, SEE = 8.1%, r = 0.83) demonstrated the sensitivity of time subtraction EFs to the performance of a background correction procedure. Conversely, densitometric measurement of ejection fraction using dual-energy subtraction was significantly less sensitive to the performance of a background correction (EFNO-BKG = 0.99 EFBKG - 5.3%, SEE = 4.3%, r = 0.96). Since background correction requires accurate definition of ventricular borders, but motion artifacts often preclude accurate border definition, it is concluded that dual-energy subtraction is a significantly more robust method for measuring left ventricular ejection fraction using densitometry. It is further concluded that identification of the systolic endocardial border is not required when performing densitometric EF measurements on dual-energy images. Drawing of the end-diastolic border alone is sufficient to produce an accurate ejection fraction measurement.

Entities:  

Mesh:

Year:  1994        PMID: 7963749     DOI: 10.1007/BF01137706

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  16 in total

1.  Limitations of the lead oxide vidicon for dual-energy digital subtraction angiography.

Authors:  M S Van Lysel
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

2.  Videodensitometric studies by a new method of quantitating the amount of contrast medium.

Authors:  J H Bürsch; P H Heintzen; R Simon
Journal:  Eur J Cardiol       Date:  1974-04

3.  Asymmetric left ventricular contraction in patients with previous myocardial infarction. Comparison of volume and dimensional characteristics derived from frontal and lateral cineangiograms.

Authors:  R D Gentzler; J H Gault; A S Hunter; A J Liedtke; D M Leaman
Journal:  Circulation       Date:  1973-08       Impact factor: 29.690

4.  Comparison of biplane and single plane left ventriculograms in patients with coronary artery disease.

Authors:  P F Cohn; R Gorlin; D F Adams; R A Chahine; P S Vokonas; M V Herman
Journal:  Am J Cardiol       Date:  1974-01       Impact factor: 2.778

5.  The use of single plane angiocardiograms for the calculation of left ventricular volume in man.

Authors:  H Sandler; H T Dodge
Journal:  Am Heart J       Date:  1968-03       Impact factor: 4.749

6.  Left ventricular volumes by single-plane cineangiography: in vivo validation of the Kennedy regression equation.

Authors:  L D Hillis; M D Winniford; G J Dehmer; B G Firth
Journal:  Am J Cardiol       Date:  1984-04-01       Impact factor: 2.778

7.  Measurement of left ventricular ejection fraction by videodensitometric analysis of digital subtraction angiograms.

Authors:  J Tobis; O Nalcioglu; A Seibert; W D Johnston; W L Henry
Journal:  Am J Cardiol       Date:  1983-10-01       Impact factor: 2.778

8.  Comparison of single and biplane ventriculography for determination of left ventricular volume and ejection fraction.

Authors:  W C Brogan; B Glamann; R A Lange; L D Hillis
Journal:  Am J Cardiol       Date:  1992-04-15       Impact factor: 2.778

9.  Densitometric regional ejection fraction: a new three-dimensional index of regional left ventricular function--comparison with geometric methods.

Authors:  F P Chappuis; T F Widmann; P Nicod; K L Peterson
Journal:  J Am Coll Cardiol       Date:  1988-01       Impact factor: 24.094

10.  Coronary blood flow measurement using an angiographic first pass distribution technique: a feasibility study.

Authors:  N J Hangiandreou; J D Folts; W W Peppler; C A Mistretta
Journal:  Med Phys       Date:  1991 Sep-Oct       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.