Literature DB >> 3548302

Determination of left ventricular ejection fraction by computer densitometric analysis of digital subtraction angiography: experimental validation and correlation with area-length methods.

S E Nissen, J L Elion, P Grayburn, D C Booth, T W Wisenbaugh, A N DeMaria.   

Abstract

Conventional methods for calculating left ventricular (LV) ejection fraction (EF) require accurate edge definition and geometric assumptions, which may be compromised in the presence of dyssynergy. Computer densitometric analysis (CDA) of digital subtraction angiography offers the potential for calculation of EF, independent of LV shape, by comparing summated brightness for regions of interest at end diastole and end systole. Therefore, the accuracy of CDA was validated for 2 mechanical heart models of differing geometry, spherical and rectangular. Both models confirmed the close correlation between calculated and measured EF (r = 0.98 and r = 0.99, respectively). Subsequently, the CDA was compared with single and biplane area-length EF calculations in 72 patients, half with a previous myocardial infarction. In patients without previous myocardial infarction, CDA correlated closely with both single-plane and biplane EF (r = 0.91 and 0.93, respectively). The close correlation was maintained regardless of whether CDA was applied to direct LV injection or intravenous digital subtraction angiography. However, in 36 patients with previous myocardial infarction, CDA correlated less closely with single-plane (r = 0.74) than with biplane (r = 0.86) area-length EF. Thus, CDA permits calculation of EF without geometric assumptions, and may be superior to the area-length method in patients with LV dyssynergy after myocardial infarction.

Entities:  

Mesh:

Year:  1987        PMID: 3548302     DOI: 10.1016/0002-9149(87)91191-x

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  3 in total

1.  Determination of cardiac ejection and valvular regurgitant fraction by on-line digital densitometry--methodology, validation, and application.

Authors:  D G Onnasch; U Jarrens; P H Heintzen
Journal:  Int J Card Imaging       Date:  1991

2.  Time-course of left atrial performance during coronary artery occlusion followed by reperfusion in anesthetized dogs by densitometric analysis of digital atrioventriculographic images.

Authors:  K Murata; M Matsuzaki; N Ohtani; M Ozaki; K Katayama; T Fujii; M Khono; S Khotoku; S Ono; N Tanaka
Journal:  Basic Res Cardiol       Date:  1993 May-Jun       Impact factor: 17.165

3.  Left ventricular dual-energy digital subtraction angiography: a motion immune digital subtraction technique.

Authors:  M S Van Lysel; W P Miller; D G Senior; V K Gupta; D J Ende; D J Albright
Journal:  Int J Card Imaging       Date:  1991