Literature DB >> 6359852

Evaluation of left ventricular contractile pattern by intravenous digital subtraction ventriculography: comparison with cineangiography and assessment of interobserver variability.

S E Nissen, D Booth, J Waters, T Fassas, A N DeMaria.   

Abstract

The accuracy and reproducibility of measurements of left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF) and regional wall motion obtained by digital subtraction ventriculography (DSV) were compared with values of direct cineangiography in 40 patients, 21 of whom were ambulatory. DSV was performed with a 1-second, 30-ml contrast injection, which yielded real-time fluoroimages composed of 512 X 512 pixels at 30 frames/s. Single-plane right anterior oblique LV volumes were calculated by area-length methods for both DSV and cineangiography. Wall motion was assessed as percent area shortening for 12 equal myocardial segments, with results classified as abnormal if greater than 2 standard deviations below the mean of 20 normal values. DSV exhibited close correlation with angiography for EDV (r = 0.88), ESV (r = 0.92) and EF (r = 0.93). Intravenous DSV and direct cineangiography were concordant in classification of LV contractile pattern in 436 of 480 (91%) myocardial segments. Measurements of DSV obtained by 2 observers showed close correlations for EDV (r = 0.88), ESV (r = 0.95) and EF (r = 0.94), and wall motion classification was in agreement in 434 of 480 (90%) LV segments. Artifacts induced by respiratory motion, persistence of contrast in the right ventricle or left atrium, or low cardiac output may have contributed to the discrepancies observed. These data indicate that DSV is accurate in assessing LV volume and EF, correlates well with cineangiography and exhibits good interobserver reproducibility.

Entities:  

Mesh:

Year:  1983        PMID: 6359852     DOI: 10.1016/0002-9149(83)90591-x

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  6 in total

1.  Assessment of left ventricular performance during percutaneous transluminal coronary angioplasty: a study by intravenous digital subtraction ventriculography.

Authors:  M S Norell; J P Lyons; A H Gershlick; J E Gardener; M T Rothman; C A Layton; R Balcon
Journal:  Br Heart J       Date:  1988-04

2.  Cardiac applications of digital subtraction angiography.

Authors:  R A Vogel; G B Mancini; E R Bates
Journal:  Int J Card Imaging       Date:  1985

3.  Comparison of digital with conventional ventriculography for quantitative right ventricular studies.

Authors:  P E Lange; W Radtke; K E Fellows; D G Onnasch; P H Heintzen
Journal:  Cardiovasc Intervent Radiol       Date:  1988       Impact factor: 2.740

Review 4.  Left ventricular imaging by digital subtraction angiography.

Authors:  R A Vogel
Journal:  Int J Card Imaging       Date:  1988

5.  Left ventricular dual-energy digital subtraction angiography: a motion immune digital subtraction technique.

Authors:  M S Van Lysel; W P Miller; D G Senior; V K Gupta; D J Ende; D J Albright
Journal:  Int J Card Imaging       Date:  1991

6.  [Digital subtraction angiocardiography--an alternative to traditional angiocardiography?].

Authors:  P Spiller; F K Schmiel
Journal:  Klin Wochenschr       Date:  1984-11-15
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.