Literature DB >> 17520306

The reduction of artifacts due to metal hip implants in CT-attenuation corrected PET images from hybrid PET/CT scanners.

John A Kennedy1, Ora Israel, Alex Frenkel, Rachel Bar-Shalom, Haim Azhari.   

Abstract

CT beam hardening artifacts near metal hip implants may erroneously enhance or diminish radiotracer uptake following CT attenuation correction (AC) of PET images. An artifact reduction algorithm (ARA) was developed to reduce metal artifacts in CT-based AC-PET. The algorithm employed a Bayes classifier to identify beam-hardening artifacts, followed by a partial correction of the attenuation map. ARA was implemented on phantom and patient 18F-FDG studies using a clinical PET/CT scanner. In phantom studies ARA successfully removed two artifacts of erroneously elevated uptake near a stainless steel hip prosthesis which were depicted in the standard CT-AC PET. ARA has also identified two targets absent on the scanner PET images. Target-to-background ratios were 1.5-3 times higher for ARA-PET than scanner images. In a patient study, metal artifacts were of lower intensity in ARA-PET as compared to standard images. Potentially, ARA may improve detectability of small lesions located near metal hip implants.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17520306     DOI: 10.1007/s11517-007-0188-8

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   3.079


  23 in total

1.  Is quantitation necessary for oncological PET studies? Against.

Authors:  Michael M Graham
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-01       Impact factor: 9.236

2.  Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner.

Authors:  EhabI M Kamel; Cyrill Burger; Alfred Buck; GustavI K von Schulthess; GerhardI W Goerres
Journal:  Eur Radiol       Date:  2002-08-23       Impact factor: 5.315

3.  Truncation artifact on PET/CT: impact on measurements of activity concentration and assessment of a correction algorithm.

Authors:  Osama Mawlawi; Jeremy J Erasmus; Tinsu Pan; Dianna D Cody; Rachelle Campbell; Albert H Lonn; Steve Kohlmyer; Homer A Macapinlac; Donald A Podoloff
Journal:  AJR Am J Roentgenol       Date:  2006-05       Impact factor: 3.959

4.  An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: experimental and clinical studies.

Authors:  Mehran Yazdi; Mehran Yazdia; Luc Gingras; Luc Beaulieu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-07-15       Impact factor: 7.038

5.  Iterative deblurring for CT metal artifact reduction.

Authors:  G Wang; D L Snyder; J A O'Sullivan; M W Vannier
Journal:  IEEE Trans Med Imaging       Date:  1996       Impact factor: 10.048

6.  Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction.

Authors:  D D Robertson; J Yuan; G Wang; M W Vannier
Journal:  J Comput Assist Tomogr       Date:  1997 Mar-Apr       Impact factor: 1.826

7.  CT vs 68Ge attenuation correction in a combined PET/CT system: evaluation of the effect of lowering the CT tube current.

Authors:  Ehab Kamel; Thomas F Hany; Cyrill Burger; Valerie Treyer; Albert H R Lonn; Gustav K von Schulthess; Alfred Buck
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-03       Impact factor: 9.236

8.  A combined PET/CT scanner for clinical oncology.

Authors:  T Beyer; D W Townsend; T Brun; P E Kinahan; M Charron; R Roddy; J Jerin; J Young; L Byars; R Nutt
Journal:  J Nucl Med       Date:  2000-08       Impact factor: 10.057

9.  The diabetic foot: initial experience with 18F-FDG PET/CT.

Authors:  Zohar Keidar; Daniela Militianu; Eyal Melamed; Rachel Bar-Shalom; Ora Israel
Journal:  J Nucl Med       Date:  2005-03       Impact factor: 10.057

10.  PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients.

Authors:  C Burger; G Goerres; S Schoenes; A Buck; A H R Lonn; G K Von Schulthess
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-04-19       Impact factor: 9.236

View more
  12 in total

1.  Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Authors:  Pardis Ghafarian; S M R Aghamiri; Mohammad R Ay; Arman Rahmim; Thomas H Schindler; Osman Ratib; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-10-20       Impact factor: 9.236

2.  Improved Image Quality in Head and Neck CT Using a 3D Iterative Approach to Reduce Metal Artifact.

Authors:  W Wuest; M S May; M Brand; N Bayerl; A Krauss; M Uder; M Lell
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-13       Impact factor: 3.825

3.  Frequency split metal artefact reduction in pelvic computed tomography.

Authors:  M M Lell; E Meyer; M Schmid; R Raupach; M S May; M Uder; M Kachelriess
Journal:  Eur Radiol       Date:  2013-03-22       Impact factor: 5.315

4.  The effect of metal artefact reduction on CT-based attenuation correction for PET imaging in the vicinity of metallic hip implants: a phantom study.

Authors:  Roy Harnish; Sven Prevrhal; Abass Alavi; Habib Zaidi; Thomas F Lang
Journal:  Ann Nucl Med       Date:  2014-04-08       Impact factor: 2.668

5.  Reduction of artefacts caused by hip implants in CT-based attenuation-corrected PET images using 2-D interpolation of a virtual sinogram on an irregular grid.

Authors:  Mehrsima Abdoli; Johan R de Jong; Jan Pruim; Rudi A J O Dierckx; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-08-18       Impact factor: 9.236

6.  False-positive 18F-fluorodeoxyglucose positron emission tomography/computed tomography in a patient with metallic implants following chondrosarcoma resection.

Authors:  P U Zhou; Jinliang Tang; Dong Zhang; Guanghui Li
Journal:  Mol Clin Oncol       Date:  2016-03-03

7.  Reduction of coil mass artifacts in high-resolution flat detector conebeam CT of cerebral stent-assisted coiling.

Authors:  I M J van der Bom; S Y Hou; A S Puri; G Spilberg; D Ruijters; P van de Haar; B Carelsen; S Vedantham; M J Gounis; A K Wakhloo
Journal:  AJNR Am J Neuroradiol       Date:  2013-05-30       Impact factor: 3.825

8.  Impact of different metal artifact reduction techniques on attenuation correction in 18F-FDG PET/CT examinations.

Authors:  Ole Martin; Joel Aissa; Johannes Boos; Katrin Wingendorf; David Latz; Christian Buchbender; Susanne Gaspers; Christina Antke; Martin Sedlmair; Gerald Antoch; Benedikt M Schaarschmidt
Journal:  Br J Radiol       Date:  2019-11-01       Impact factor: 3.039

Review 9.  Periprosthetic bone loss: diagnostic and therapeutic approaches.

Authors:  Loredana Cavalli; Maria Luisa Brandi
Journal:  F1000Res       Date:  2014-06-17

10.  MR image based approach for metal artifact reduction in X-ray CT.

Authors:  Andras Anderla; Dubravko Culibrk; Gaspar Delso; Milan Mirkovic
Journal:  ScientificWorldJournal       Date:  2013-11-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.